Preferred Language
Articles
/
jbcd-2867
Clinical Assessment and Cytomorphometric Analysis of Buccal Mucosal Cells in Behçet’s Disease Patients
...Show More Authors

Background: Behçet’s disease (BD) is a disorder of systemic inflammatory condition. Its important features are represented by recurrent oral, genital ulcerations and eye lesions. Aims. The purpose of the current study was to evaluate and compare cytological changes using morphometric analysis of the exfoliated buccal mucosal cells in Behçet’s disease patients and healthy controls, and to evaluate the clinical characteristics of Behçet’s disease. Methods. Twenty five Behçet’s disease patients have been compared to 25 healthy volunteers as a control group. Papanicolaou stain was used for staining the smears taken from buccal epithelial cells to be analyzed cytomorphometrically. The image analysis software has been used to evaluate cytoplasmic, nuclear areas and the nuclear/cytoplasmic ratio (N/C). Results. The cytoplasmic and nuclear area of buccal cells of Behçet’s disease cases were significantly smaller than those of healthy volunteers. However, the N/C ratio remained the same when compared between both groups. All patients had recurrent oral ulcer and none of the patient had cardiac and pulmonary symptoms. Conclusion. Cytomorphometric analysis and exfoliative cytology techniques have the ability to detect the alterations in buccal epithelial cells caused by Behçet’s disease.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 16 2026
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Determination of Methionine Via Chemiluminescence-Continuous Flow Injection Analysis
...Show More Authors

The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto

... Show More
View Publication
Publication Date
Thu Aug 26 2021
Journal Name
International Journal Of Applied Mechanics And Engineering
Probabilistic Mesoscale Analysis of Concrete Beams Subjected to Flexure
...Show More Authors
Abstract<p>In this paper, the probabilistic behavior of plain concrete beams subjected to flexure is studied using a continuous mesoscale model. The model is two-dimensional where aggregate and mortar are treated as separate constituents having their own characteristic properties. The aggregate is represented as ellipses and generated under prescribed grading curves. Ellipses are randomly placed so it requires probabilistic analysis for model using the Monte Carlo simulation with 20 realizations to represent geometry uncertainty. The nonlinear behavior is simulated with an isotropic damage model for the mortar, while the aggregate is assumed to be elastic. The isotropic damage model softening be</p> ... Show More
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Deflection Analysis of an Elastic Single Link Robotic Manipulator
...Show More Authors

Abstract

Robotics manipulators with structural flexibility provide an attractive alternative to rigid robotics manipulators for many of the new and evolving applications in robotics. In certain applications their use is unavoidable. The increased complexity in modeling and control of such manipulators is offset by desirable performance enhancements in some respects. In this paperthe single- link flexible robotics manipulator was designed and implemented from Perspex and designed with 0.5 m length , 0.02 m width and with 0.004 m thickness with mass located at the tip. There are four subsystems; motion, control, accelerometer and gyro and a host computer subsystem. The work principle of single-link robotics manipul

... Show More
View Publication Preview PDF
Publication Date
Thu May 15 2025
Journal Name
Route Educational And Social Science Journal
A PSYCHOSOCIAL ANALYSIS OF APPROACHING ZANZIBAR BY TINA HOWE
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Journal Of Economics And Administrative Sciences
Bayes Analysis for the Scale Parameter of Gompertz Distribution
...Show More Authors

In this paper, we investigate the behavior of the bayes estimators, for the scale parameter of the Gompertz distribution under two different loss functions such as, the squared error loss function, the exponential loss function (proposed), based different double prior distributions represented as erlang with inverse levy prior, erlang with non-informative prior, inverse levy with non-informative prior and erlang with chi-square prior.

The simulation method was fulfilled to obtain the results, including the estimated values and the mean square error (MSE) for the scale parameter of the Gompertz distribution, for different cases for the scale parameter of the Gompertz distr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Aug 31 2017
Journal Name
Journal Of Engineering
Energy Analysis of Solar Collector With perforated Absorber Plate
...Show More Authors

The thermal performance of three solar collectors with 3, 6 mm and without perforation absorber plate was assessed experimentally. The experimental tests were implemented in Baghdad during the January and February 2017. Five values of airflow rates range between 0.01 – 0.1 m3/s were used through the test with a constant airflow rate during the test day. The variation of the following parameters air temperature difference, useful energy, absorber plate temperature, and collector efficiency was recorded every 15 minutes. The experimental data reports that the increases  the number of absorber plate perforations with a small diameter is more efficient rather than increasing the hole diameter of the absorber plate with decr

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 21 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Analysis Tax Advantage of Financing Lease: An Empirical Study
...Show More Authors

The Purpose of this study are  analyze financial lease advantage through analyze and discuss financial lease cost, and achieve tax advantage to reach study objective. study include two firms ,oil firm and construction firm with limited liability. The inductive method is used for the applied part in analyzing the financial data of the companies considered in 2011-2015.The result of the study shows that the financial  lease achieve present value of the costs is positive. This study found out the results that verify the hypothesis: The tax advantage of financial Leasing is characterized by decreasing cost and achieving higher tax shield. The study also found the most important recommendations of awareness of the benefits arising f

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
FREE VIBRATION ANALYSIS OF NOTCHED COMPOSITE LAMINATED CANTILEVER BEAMS
...Show More Authors

The present work divided into two parts, first the experimental side which included the
measuring of the first natural frequency for the notched and unnotched cantilever composite beams
which consisted of four symmetrical layers and made of Kevlar- epoxy reinforced. A numerical
study covers the effect of notches on the natural frequencies of the same specimen used in the
experimental part. The mathematical model for the beam contains two open edges on the upper
surface. The effect of the location of cracks relative to the restricted end, depth of cracks, volume
fraction of fibers and orientation of the fiber on the natural frequencies are explored. The results
were calculated using the known engineering program (ANSY

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Spectrophotometrically Analysis of PMMA as a low – Doses Dosimeter
...Show More Authors

Polymethylmethacrylate film (PMMA) of thickness 75 μm was evaluated Spectrophotometrically for using it as a low-doses gamma radiation dosimeter. The doses were examined in the range 0.1 mrad-10 krad. Within an absorption band of 200-400 nm, the irradiated films showed an increase in the absorption intensity with increasing the absorbed doses. Calibration curves for the changes in the absorption differences were obtained at 218, 301, and 343 nm. At 218 nm the response for the absorbed doses is a linear in the range 10 mrad- 10 krad. Hence it is recommended to be adopted as an environmental low doses dosimeter

View Publication Preview PDF
Publication Date
Wed Jan 01 2025
Journal Name
Lecture Notes In Networks And Systems
Symlet Analysis for ECG-Based Diagnosis of Heart Dysfunction
...Show More Authors

View Publication
Scopus Crossref