Background: Recently with improvement of dental implantology science, osseointegrated implants show a considerable durability, however; failures are not completely avoidable. Matrix metalloproteinase-2 (MMP-2) expression is disturbed in many pathological conditions such as peri-implantitis and periodontitis. This study was carried out to investigate the tissue expression of MMP-2 in the extracellular matrix of osseointegrated and diseased implants. Subjects and methods: Gingival biopsies were collected from six patients having osseointegrated or working implants and twenty with diseased or non osseointegrated implants and (6) controls having no implants. In situ hybridization technique was used to analyze the changes in immunoreactivity of ECM-controlling MMP-2. Results: The findings of the present study indicate that the expression of MMP2 was significantly elevated in failed implants versus healthy implants (P<0.01). In addition, MMP-2 was detected in peri-implant sites with ongoing bone loss, cavitations and inflammatory reaction. Conclusion: The in situ hybridization technique, showed clear evidence that MMP-2, which is involved in the process of osseointegration and bone remodeling, increase greatly in the presence of bone destruction, cavitations, severe inflammation and fibrous tissue formation. The data link titanium- induced bone remodeling to changes in expression and distribution of MMP-2.
Background: Heat-cured poly (methyl methacrylate) the principal material for the fabrication of denture base have a relatively poor mechanical properties. The aim of this study was to investigate the effect of glass flakes used as reinforcement on the surface hardness and surface roughness of the heat-processed acrylic resin material. Material and method: Glass flakes (product code: GF002) pretreated with silane coupling agent were added to Triplex® denture base powder using different concentrations. A total of 100 specimens of similar dimensions (65 x 10 x 2.5) mm were prepared, subdivided into 2 main groups of 50 specimens for each of the study tests. Ten specimens for the control group and 40 specimens for each of the experimental gro
... Show MoreBACKGROUND: The degree of the development of coronary collaterals is long considered an alternate–that is, a collateral–source of blood supply to an area of the myocardium threatened with vascular ischemia or insufficiency. Hence, the coronary collaterals are beneficial but can also promote harmful (adverse) effects. For instance, the coronary steal effect during the myocardial hyperemia phase and that of restenosis following coronary angioplasty.
The study in duded isolation and identification of microbial isolates from oral cavity to 10 volunteers, diagnosed within the three groups: Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus spp. and Candida albicans . The sensitivity test of all isolates bacteria Streptococcus spp. , S. aureus and S. epidermidis showed high resistance to Ampicillin(100)%,followed Methicillin (88.88)% and Amoxicillin / clavulanic acid(77.77)%, while the resistance for each of Vancomycin and Amoxicillin were (66.66)%, and the resistance to Erythromycin and Pencillin (55.55)% to each of them. The results showed less resistance to Trimethoprim (22.22)% and Cefalotine (11.11)% of all bacteria isolate. Investigation of the pre
... Show MoreSince the COVID-19 pandemic began, there have been concerns related to the preparedness of healthcare workers (HCWs). This study aimed to describe the level of awareness and preparedness of hospital HCWs at the time of the first wave.
This multinational, multicenter, cross-sectional survey was conducted among hospital HCWs from February to May 2020. We used a hierarchical logistic regression multivariate analysis to adjust the influence of variables based on awareness and preparedness. We then used association rule mining to identify relationships between HCW confidence in handling suspected
This study is a complementary one to an extended series of research work that aims to produce a thermodynamiclly stable asphalt –sulfur blend. Asphalt was physically modified wiht different percentages of asphaltenes , oxidized asphaltenes and then mixed with sulfur as an attempt to obtaine a stable compatible asphalt-sulfur blend. The homogeneneity of asphalt-asphaltenes[oxidized asphaltenes]-sulfur blends were studied microscopically and the results are prsented as photomicrographs. Generally more stable and compatible asphalt-sulfur blends were obtained by this treatment.
An experimental study is carried out on the effect of vortex generators (Circular and square) on the flow and heat transfer at variable locations at (X = 0.5, 1.5, 2.5 cm) ahead of a heat exchanger with Reynolds number ranging from 62000< Re < 125000 and heat flux from 3000 ≤ q ≤ 8000 W/m2 .
In the experimental investigation, an apparatus is set up to measure the velocity and temperatures around the heat exchanger.
The results show that there is an effect for using vortex generators on heat transfer. Also, heat transfer depends on the shape and location. The circular is found t
... Show MoreThe paper presents the results of the research on the influence of the adjuvant concentration on the size of the drops produced by the spray nozzles of agricultural sprayers. For the tests, adjuvant Normaton with the composition of total nitrogen, amide nitrogen (N-NH2) and phosphorus pentoxide (P2O5) was used. The adjuvant was added to the water taken from the municipal water supply system of the city of Lublin. The tests were carried out for three concentrations, i.e. 75%, 100%, and 125% of the adjuvant concentration recommended by the manufacturer, and water without the adjuvant. The surface tension of water with adjuva
This paper presents an experimental and numerical study which was carried out to examine the influence of the size and the layout of the web openings on the load carrying capacity and the serviceability of reinforced concrete deep beams. Five full-scale simply supported reinforced concrete deep beams with two large web openings created in shear regions were tested up to failure. The shear span to overall depth ratio was (1.1). Square openings were located symmetrically relative to the midspan section either at the midpoint or at the interior boundaries of the shear span. Two different side dimensions for the square openings were considered, mainly, (200) mm and (230) mm. The strength results proved that the shear capacity of the dee
... Show More