Background: Maxillary canines are important aesthetically and functionally, but impacted canines are more difficult and time consuming to treat, the aim of this study is to investigate with multi-detector computed tomography the correlation between the bone density and the upper canine impaction. Material and method: A sample of Unilaterally impacted maxillary canines from 24 patients (19 female, 5 male) who were referred to accurately localize the impacted canines at al- Karkh general hospital were evaluated by a volumetric 3-d images by the multi-detector computed tomography to accurately measure the bone density of the maxillary cortical palate of the maxillary impacted canine side and compare it with the other side of the normally erupted canine. Results: The statistical descriptive analysis showed that the ratio of the maxillary canine impaction was higher in females than in males, also the it revealed that the mean bone density of the cortical bone was greater in the maxillary impacted canine side (affected side) than in the control side (the side of the normally erupted canine), the Wilcoxon signed ranks test showed a significant difference in the mean bone density between the affected side and the control side. Conclusions: The increased bone density of the maxillary cortical plate could be an obstructive factor that cause maxillary canine impaction.
Uranium concentrations in soil were determined for ten locations in Salahdin governorate using CR-39 track detector, fission fragments track technique was used, the nuclear reaction of nuclear fission fragments obtained by the bombardment of 235U with thermal neutrons from (Am-Be) neutron source with flux (5000n.cm-2.s-1), the concentration values were calculated by a comparison with standard samples. The results of the measurements show that the uranium concentration in soil samples various from 0.42±0.018ppm in Beji province to 0.2±0.014 ppm in Tooz province with an average (0.31±0.08ppm), the values of uranium concentration in all samples are within the permissible limits universally.
In the present work, a set of indoor Radon concentration measurements was carried out in a number of rooms and buildings of Science College in the University of Mustansiriyah for the first time in Iraq using RAD-7 detector which is an active method for short time measuring compared with the passive method in solid state nuclear track detectors (SSNTD's). The results show that, the Radon concentrations values vary from 9.85±1.7 Bq.m-3 to 94.21±34.7 Bq.m-3 with an average value 53.64±26 Bq.m-3 which is lower than the recommended action level 200-300 Bq/m3 [ICRP, 2009].
The values of the annual effective dose (A.E.D) vary from 0.25 mSv/y to 2.38 mSv/y, with an average value 1.46±0.67 mSv/y which is lower than the recommended the rang
Ge-Au infrared photoconductive detection was prepared from germanium single crystal which were doped with different gold concentration using thermal evaporation. The spectral resonsivity (Rλ), spectral detectivity (D*) were determined as function of wavelength, also the resistance, conductivity in dark and with illumination to infrared radiation, the gain and relative photo response have been measured with different gold concentration. Remarkable improvements in the photoresponse gain were observed for the highest resistance specimen at the expense of spectral detectivity values.
Addition of bioactive materials such as Titanium oxide (TiO2), and incorporation of bio inert ceramic such as alumina (Al2O3), into polyetheretherketone (PEEK) has been adopted as an effective approach to improve bone-implant interfaces. In this paper, hot pressing technique has been adopted as a production method. This technique gave a homogenous distribution of the additive materials in the proposed composite biomaterial. Different compositions and compounding temperatures have been applied to all samples. Mechanical properties and animal model have been studied in all different production conditions. The results of these new TiO2/Al2O3/PEEK biocomposites with different
... Show MoreBackground: Trauma to the anterior teeth is a common injury in young children. Themaxillary incisors being the most affected. Although root fractures are rare, theydo occur and were previously and often considered hopeless and were extracted.The time between the injury and the initiation of treatment, level of the fractureline, and stage of root development are some criteria to be considered whenchoosing a treatment approach for a complicated tooth fracture. This case reportdescribes the management of a traumatized immature maxillary central incisorwith Elise class IV fracture with vertical oblique subgingival fracture of the root.Materials and method: Apexification was carried out using biodentine followed byremoval of the fracture
... Show MoreThis study aimed to determine the measurements and classification of Schneider membrane thickness correlated to age and sex factors using cone beam computed tomography (CBCT). Methods: The study included CBCT images for 100 maxillary sinuses of 50 consecutive patients, and the thickness of the maxillary sinus membrane (Schneiderian membrane) was measured in coronal view from the lowest point in the floor of the maxillary sinus to the highest point. The thickness of the Schneiderian membrane was classified into 4 types. Results: The study result revealed that out of the total cases, 45% of sinus membranes were classified as type 2, while only 10% were classified as type 4. The most frequent type of membrane thickness diagnosed in the age gro
... Show MoreBackground: Osteoporosis is denoted by low bone mass and microarchitectural breakdown of bone tissue, directing to increased fracture risk and bone fragility. Fractures may lead to a decreased quality of life and increased medical costs. Thus, osteoporosis is widely considered a significant health concern.
Objective. This study aimed to compare quantitative computed tomography (QCT) and dual-energy X-Ray absorptiometry (DXA) to detect osteoporosis in postmenopausal women.
Subjects and Methods. We measured spinal volumetric bone mineral density (BMD) with QCT and areal spinal and hip BMD with DXA in 164 postmenopausal women. We calculated the osteo
... Show MoreBeen manufacturing detector Altosalih optical pattern contact metal semiconductor through deposition poles of aluminum metal on the chips of crystal cadmium Tleraad (CdTe) with directional [111] and growing with laboratory and annealed at a temperature 80c for 30 minutes and eat Study of some electrical properties nailed and scoutNmadj ??????? copper with non ??????? models to see effect Alichoab well research deals impact Alichoab and frequency detector resistance