Preferred Language
Articles
/
jbcd-2752
Effect of dispensing method and curing modes on the microleakage of composite resins
...Show More Authors

Background: Vibration decreases the viscosity of composite, making it flow and readily fit the walls of the cavity. This study is initiated to see how this improved adaptation of the composite resin to the cavity walls will affect microleakage using different curing modes

Materials and methods: Standard Class V cavities were prepared on the buccal surface of sixty extracted premolars. Teeth were randomly assigned into two groups (n=30) according to the composite condensation (vibration and conventional) technique, then subdivided into three subgroups (n=10) according to light curing modes (LED-Ramp, LED-Fast and Halogen Continuous modes). Cavities were etched and bonded with Single Bond Universal then restored with Filtek® Z350 (3M ESPE, USA). In the vibration group, condensation was done using CompothixoTM (Kerr, Switzerland). In the conventional group, condensation was done with hand plugger. Curing modes for all groups were LED-Ramp, LED-Fast and halogen continuous modes, respectively. Samples stored in distilled water at 37°C for seven days, and painted completely with two layers of nail varnish with only 1 mm around the composite restoration left. Samples were thermocycled, immersed in 2% methylene blue solution for 3 hours, and sectioned longitudinally. Dye penetration was assessed under a stereomicroscope. Data were analyzed by Kruskal-Wallis and Mann-Whitney U tests with p <0.05 considered significant.

Results: Vibration group showed less microleakage (P=0.028). In the conventional group there were no differences by using different curing modes (P=0.277). In the vibration group no differences were found between LED-Ramp and LED-Fast mode (P=0.989). However, there were significant differences between LED-Fast and halogen (P=0.05) and between LED-Ramp and halogen group (P=0.001). Microleakage scores of all cervical walls were higher than the occlusal walls (P=0.001). Occlusal walls leakage for conventional and vibration groups were not different (P=0.475), while there were significant differences between them at cervical walls (P=0.001).

Conclusion: Vibration with LED-Ramp curing mode may decrease marginal leakage of composite restoration placed in Standard Class V tooth preparations.

Keywords: Composite resin, Vibration, Condensation, Compothixo, Microleakage,

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 16 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Annealing Temperature and Thickness on the Structural and Optical Properties of CdSeThin Films
...Show More Authors

CdSe alloy has been prepared successfully from its high purity elements. Thin films of this alloy with different thicknesses (300,700)nm have been grown on glass substrates at room temperature under very low pressure (10-5)Torr with rate of deposition (1.7)nm/sec by thermal evaporation technique, after that these thin films have been heat treated under low pressure (10-2)Torr at (473,673)K for one hour. X-ray patterns showed that both CdSe alloy and thin films are polycrystalline and have the hexagonal structure with preferential orientation in the [100] and [002] direction respectively. The optical measurements indicated that CdSe thin films have allowed direct optical energy band gap, and it increases from (1.771.84) eV and from (1.6-1

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 03 2015
Journal Name
Iraqi Journal Of Science
New multispectral images classification method based on MSR and Skewness implementing on various sensor scenes
...Show More Authors

Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
The Effect of Ceramic Coating on Performance and Emission of Diesel Engine Operated on Diesel Fuel and Biodiesel Blends
...Show More Authors

In this work, the effect of ceramic coating on performance, exhaust gas temperature and gases emissions of diesel engine operated on diesel fuel and biodiesel blends was investigated. A conventional four stroke, direct injected, single cylinder, diesel engine was tested at constant speed and at different load conditions using diesel fuel and biodiesel blends. The inlet and exhaust valves, the head of piston and cylinder head of the engine were coated by ceramic materials. Ceramic layers were made of (210-240) μm of Al2O3 and (30-60) μm of 4NiCr5Al as a bond coat for inlet and exhaust valves and (350-400) μm of YSZ and (50-100) μm of 4NiCr5Al as a bond coat for head of piston and (280-320) μm of Sic and (40-80) μm of 4NiCr5Al as a b

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 16 2013
Journal Name
International Journal Of Pharmacy And Pharmaceutical Sciences
Effects of mucoadhesive polymers combination on the properties of lisinpril buccal tablets prepared by wet granulation method
...Show More Authors

Scopus (4)
Scopus
Publication Date
Fri Dec 29 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Study the Effect of Ultraviolet on the Compression and Hardness Property for Hybrid Material
...Show More Authors

The study was carried out by reinforcing the resin matrix material

which was (Epoxy- Ep828) by useing Kevlar fibers and glass fibers type (E-gl ass) both or them in the form of woven roving and poly propylene tlbcrs  in  the form chopped  strand  mats.  wi th (30%)  volume  fraction. Some mechan i cal  properties of the were prepared composite specimens U ltraviolet   radiation  were  stuied   after   being  subjected  to  different weathering conditi ons i ncluded. Compression and hardness testing were carried out using Briel! method so as to compare between composite behavior i n the environments previously mentioned .

 <

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF The effect of nanoelectrodes number and length on enhancing the THz photomixer performance
...Show More Authors

Abstract: Despite the distinct features of the continuous wave (CW) Terahertz (THz) emitter using photomixing technique, it suffers from the relatively low radiation output power. Therefore, one of effective ways to improve the photomixer emitter performance was using nanodimensions electrodes inside the optical active region of the device. Due to the nanodimension sizes and good electrical conductivity of silver nanowires (Ag-NWs), they have been exploited as THz emitter electrodes. The excited surface plasmon polariton waves (SPPs) on the surface of nanowire enhances the incident excitation signal. Therefore, the photomixer based Ag-NW compared to conventional one significantly exhibits higher THz output signal. In thi

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
the effect of temperatures and humidity rates on the mean weight loss from developement
...Show More Authors

The effect of some environmental factors in the loss rate for high weights virgins are full to the screwworm fly of the ancient world and included temperatures 15,20,25,30,35,40 study showed that the rate of loss in weight virgins advanced to full participants at a temperature of 15 C while notgets evolution

View Publication Preview PDF
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
The Effect of Heat Treatment on the Magnetic and Mechanical properties offe - Ni alloys.
...Show More Authors

The aim of this work is studying the binary system ??'??? Ni?)with two ratios (y=36,80) by using casting method for preparing the samples.Magnetic and Mechanical properties have been studidt different httrea^nttem^rature.All the alloys were found a ferromagnetic behavior and sensitive to the heat treatment. Best properties were found at the heat treatment 1100 C°.A significant different results were found above 1100C° for lower magnetic and mechanical values. This is possibly due to the change on the degree of magnetic moment orders, in which most of the moments are started to remove from coupled ferromagnetically.?

View Publication Preview PDF
Publication Date
Sat Mar 31 2018
Journal Name
Journal Of Engineering
Effecting of pH Parameter on Simulated Wastewater Treatment Using Electrocoagulation Method
...Show More Authors

The aim of the present research is to investigate the effecting of pH parameter on the feasibility of lead removal from simulated wastewater using an electrochemical system. Electrocoagulation method is one of electrochemical technology which is used widely to treat industrial wastewater. Parameters affecting this operation, such as initial metal concentration, applied current, stirrer speed, and contact time of electroprocessing were taken as 155ppm, 1.5 Ampere, 150 rpm, 60 minutes respectively. While pH of the simulated wastewater was in the range of  2 to 12 in the experiments. It was found from the results that pH is an important parameter affecting lead removal operation. The best value of pH parameter is appro

... Show More
View Publication Preview PDF
Scopus (19)
Crossref (15)
Scopus Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Int. J. Advance Soft Compu. Appl,
Arabic and English Texts Encryption Using Proposed Method Based on Coordinates System
...Show More Authors

Preview PDF