Preferred Language
Articles
/
jbcd-2752
Effect of dispensing method and curing modes on the microleakage of composite resins
...Show More Authors

Background: Vibration decreases the viscosity of composite, making it flow and readily fit the walls of the cavity. This study is initiated to see how this improved adaptation of the composite resin to the cavity walls will affect microleakage using different curing modes

Materials and methods: Standard Class V cavities were prepared on the buccal surface of sixty extracted premolars. Teeth were randomly assigned into two groups (n=30) according to the composite condensation (vibration and conventional) technique, then subdivided into three subgroups (n=10) according to light curing modes (LED-Ramp, LED-Fast and Halogen Continuous modes). Cavities were etched and bonded with Single Bond Universal then restored with Filtek® Z350 (3M ESPE, USA). In the vibration group, condensation was done using CompothixoTM (Kerr, Switzerland). In the conventional group, condensation was done with hand plugger. Curing modes for all groups were LED-Ramp, LED-Fast and halogen continuous modes, respectively. Samples stored in distilled water at 37°C for seven days, and painted completely with two layers of nail varnish with only 1 mm around the composite restoration left. Samples were thermocycled, immersed in 2% methylene blue solution for 3 hours, and sectioned longitudinally. Dye penetration was assessed under a stereomicroscope. Data were analyzed by Kruskal-Wallis and Mann-Whitney U tests with p <0.05 considered significant.

Results: Vibration group showed less microleakage (P=0.028). In the conventional group there were no differences by using different curing modes (P=0.277). In the vibration group no differences were found between LED-Ramp and LED-Fast mode (P=0.989). However, there were significant differences between LED-Fast and halogen (P=0.05) and between LED-Ramp and halogen group (P=0.001). Microleakage scores of all cervical walls were higher than the occlusal walls (P=0.001). Occlusal walls leakage for conventional and vibration groups were not different (P=0.475), while there were significant differences between them at cervical walls (P=0.001).

Conclusion: Vibration with LED-Ramp curing mode may decrease marginal leakage of composite restoration placed in Standard Class V tooth preparations.

Keywords: Composite resin, Vibration, Condensation, Compothixo, Microleakage,

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Sep 01 2007
Journal Name
Al-khwarizmi Engineering Journal
Study the influence of the reinforced material geometrical shape on the internal stresses in the composite materials
...Show More Authors

In this paper the reinforced materials manufactured from steel continues fibers are used in Aluminum matrix to build a composite material. Most of researches concentrated on reinforced materials and its position in the matrix according to its size and distribution, and their effects on the magnitude of different kinds of the stresses, so this paper presents and concentrate on the geometrical shape of reinforced material and its effects on the internal stresses and strains on the composite strength using FEM as a method for analysis after loaded by certain force showing the deference magnitudes of stresses according to the different geometrical shapes of reinforced materials.

 

View Publication Preview PDF
Publication Date
Fri Oct 12 2018
Journal Name
International Journal Of Dynamics And Control
Decentralized adaptive partitioned approximation control of high degrees-of-freedom robotic manipulators considering three actuator control modes
...Show More Authors

View Publication
Scopus (11)
Crossref (9)
Scopus Crossref
Publication Date
Mon Jun 09 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation of Some Mechanical Properties of Autopolymerizing Acrylic Resin with the Modified One after Changing the Curing Environment: (In vitro Study)
...Show More Authors

Background: Studying and investigating the transverse strength(Ts), impact strength(Is), hardness (Hr) and surface roughness(Ra) of conventional and modified autopolymerizing acrylic resin with different weight percentages of biopolymer kraftlignin, after curing in different water temperatures; 40°C and 80°C. Material and Methods: Standard acrylic specimens were fabricated according to ADA specification No.12 for transverse strength, ISO 179 was used for impact testing, Shore D for hardness and profilometerfor surface roughness. The material lignin first dispersed in the monomer, then the powder PMMA is immediately added. Ligninadded in different weight percentages. Then cured using pressure pot (Ivomet) in two temperatures;40°C a

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 24 2025
Journal Name
Advances In Structural Engineering
Experimental and numerical investigation on the behavior of composite reinforced concrete columns encased by steel section and hybrid GFRP section
...Show More Authors

GFRP was employed in constructions as an alternative to steel, which has many advantages like lightweight, large tensile strength and resist corrosion. Existing researches are insufficient in studying the influence of hybrid reinforced concrete composite columns encased by GFRP I-section (RCCCEG) and I-section steel (RCCCES). In this study twenty one (RC) specimens of a cross-section of 130 mm × 160 mm, with different length (long 1600 mm and short 750 mm) were encased by using I-section (steel and GFRP) and tested under various loading (concentric, eccentric and flexural loads). The test was focused on the influence of many parameters; load-carrying capacity, mode of failure, deformation and drawing an interaction diagram (N-

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Wed Jul 31 2019
Journal Name
Journal Of Engineering
Comparison Study of Adsorption of Lead and Methylene Blue on Zeolite, Activated Carbon and Their Composite Materials
...Show More Authors

In this study, composite materials consisting of Activated Carbon (AC) and Zeolite were prepared for application in the removal of methylene blue and lead from an aqueous solution. The optimum synthesis method involves the use of metakaolinization and zeolitization, in the presence of activated carbon from kaolin, to form Zeolite. First, Kaolin was thermally activated into amorphous kaolin (metakaolinization); then the resultant metakaolin was attacked by alkaline, transforming it into crystalline zeolite (zeolitization). Using nitrogen adsorption and SEM techniques, the examination and characterization of composite materials confirmed the presence of a homogenous distribution of Zeolite throughout the activated carbon.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jul 29 2022
Journal Name
Research Journal Of Pharmacy And Technology
Characterization and Testing the properties of PEKK- Strontium- hydroxyapatite composite material
...Show More Authors

Polymers, being one of the most important materials in dentistry, offer great physical and mechanical qualities, as well as good biocompatibility. Aim of this study was done to evaluate the Polyetherketoneketone and Polyetherketoneketone polymer composite material used as dental implant through tensile strength, Fourier Transform Infrared analysis FTIR, and wettability). Polyetherketoneketone composites (Polyetherketoneketone and Strontium-containing hydroxyapatite) with selected weight percentage ratios of (0, 10%, 20%, 30%), were fabricated using a compression molding technique”, The study involved Samples preparation (sheets) shaped and form into the desired shape according to standard for tests which included tensile strength,

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Sun Sep 22 2019
Journal Name
Baghdad Science Journal
Geometry, and Normal Modes of Vibration (3N-6) for Di and Tetra-Rings Layer (6, 0) Linear (Zigzag) SWCNTs; A DFT Treatment
...Show More Authors

            Density Functional Theory (DFT) method of the type (B3LYP) and a Gaussian basis set (6-311G) were applied for calculating the vibration frequencies and absorption intensities for normal coordinates (3N-6) at the equilibrium geometry of the Di and Tetra-rings layer (6, 0) zigzag single wall carbon nanotubes (SWCNTs) by using Gaussian-09 program. Both were found to have the same symmetry of D6d point group with C--C bond alternation in all tube rings (for axial bonds, which are the vertical C--Ca bonds in rings layer and for circumferential bonds C—Cc in the outer and mid rings bonds). Assignments of the modes of vibration IR active and inactive vibration frequ

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Jun 09 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of some mechanical properties of Imprelon® and Duran® thermoplastic Biostar machine sheets in comparison with some types of acrylic resins
...Show More Authors

Background: Imprelon® Biostar foils are new alternative tray material that has become increasingly popular because oftheir several advantages. Also, (Duran®) is another type of Biostar foils which is used in splint therapy. This study assessed some mechanical properties of these two types Biostar sheets in comparison with some types of acrylic resins used for construction of trays and splints. Materials and Methods: A total of 150 specimens were prepared, 30 specimens for each test, 10 for each group material in order to assess some mechanical properties of the Imprelon® Biostar foil (dimension stability, surface roughness and shear bond strength of Imprelon® materialto zinc oxide impression material) and compare them to that of the oth

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 18 2022
Journal Name
Dental Hypotheses
Microleakage Evaluation of Glass Hybrid Restoration Following Usage of Papain-Based Gel and Ceramic Bur for Caries Removal: An in Vitro Study
...Show More Authors

Scopus Crossref
Publication Date
Sat Dec 02 2023
Journal Name
Journal Of Engineering
Discussion on the Structural Design Index and Design Method of Widening and Splicing Lane of Old Asphalt Pavement
...Show More Authors

The splicing design of the existing road and the new road in the expansion project is an important part of the design work. Based on the analysis of the characteristics and the load effect of pavement structure on splicing, this paper points out that tensile crack or shear failure may occur at the splicing under the repeated action of the traffic load on the new/old pavement. According to the current structure design code of asphalt pavement in China, it is proposed that the horizontal tensile stress at the bottom of the splicing layer and the vertical shear stress at other layers of the splicing line should be controlled by adjusting the position and size of the excavated steps in addition to the conventional design ind

... Show More
View Publication Preview PDF
Crossref