Background: Diabetic mellitus type ? is a metabolic disorder of diverse etiological factors, characterized by hyperglycemia resulting from an absolute deficiency of insulin affected childhood and adolescent. Some of these patients seek an orthodontic care .The orthodontist who is treating these medically compromised patients should have a working knowledge of the multitude of medically complex problems. This information will support and enable for delivery of high standards of dental care in general and orthodontic care in particular. The aim of this study was to analyze serum IgG levels and salivary secretory IgA (sIgA) levels in human dentine extract (HDE) before (T0) and 6 months after (T6) orthodontic treatment and to correlate anti-HDE autoantibodies to root resorption in well-controlled type ? diabetic patients. Materials and methods: Sixty individuals, who were attending to Al-Mustansiriya National Diabetes Center from April to October, 2012 and classified as well- controlled type ? diabetic patients (HbA1c <8.5), were participating in this study .The mean age of the whole samples was (15±1 SD ) years, thirty three of them(18 males and 15 females) were not wearing orthodontic appliance and were selected as the controls, while twenty seven of them (12 males and 15 females) were wearing orthodontic appliance . Periapical radiographs of the upper central incisors , unstimulated saliva and serum samples were obtained of all patients before(T0) and 6 months after(T6) orthodontic treatment. Anti-dentine antibody (Ab) levels were determined by mean of enzyme linked immune sorbant assay (ELISA) technique. At T6, root resorption was classified as grade 0 (no resorption), grade 1 (slight resorption), and grade 2 (moderate to severe resorption). Chi square test and T- test were used to assess the association between qualitative and quantitative results respectively ,while paired t- test was used to analyze the results before(T0) and 6 months after(T6) orthodontic treatment. Differences were considered significant at P<0.05. Results: There was statistical significant difference in the level of (anti- dentine Ab) in saliva between the two study groups at T0 and T6, its level was higher in the wearing group comparing with non wearing group, while it didn’t differ in serum. In the wearing group, the level of anti -dentine antibody in serum and saliva significantly decreased at T6 comparing with its level at T0. High level of the (anti -dentin Ab) shown in serum and saliva in grade 1 root resorption (R1) comparing with grade 0 root resorption (R0) at T0 and also at T6. Conclusions: The results of this study indicate that the anti -dentin antibody plays an important role in the detection of root resorption during orthodontic treatment in well- controlled diabetic patients type ? and its level is different according to the grade of root resorption in both saliva and serum.
In this work, wide band range photo detector operating in UV, Visible and IR was fabricated using carbon nanotubes (MWCNTs, SWCNTs) decorated with silver nanoparticles (Ag NPs). Silicon was used as a substrate to deposited CNTs/Ag NPs by the drop casting technique. Polyamide nylon polymer was used to coat CNTs/Ag NPs to enhance the photo-response of the detector. The electro-exploding wire technology was used to synthesize Ag NPs. Good dispersion of silver NPs achieved by a simple chemistry process on the surface of CNTs. The optical, structure and electrical characteristic of CNTs decorated with Ag NPs were characterized by X-Ray diffraction and Field Emission Scanning Electron Microscopy. X-ray diffra
... Show MoreMany consumers of electric power have excesses in their electric power consumptions that exceed the permissible limit by the electrical power distribution stations, and then we proposed a validation approach that works intelligently by applying machine learning (ML) technology to teach electrical consumers how to properly consume without wasting energy expended. The validation approach is one of a large combination of intelligent processes related to energy consumption which is called the efficient energy consumption management (EECM) approaches, and it connected with the internet of things (IoT) technology to be linked to Google Firebase Cloud where a utility center used to check whether the consumption of the efficient energy is s
... Show MoreThe solution gas-oil ratio is an important measurement in reservoir engineering calculations. The correlations are used when experimental PVT data from particular field are missing. Additional advantages of the correlations are saving of cost and time.
This paper proposes a correlation to calculate the solution gas -oil ratio at pressures below bubble point pressure. It was obtained by multiple linear regression analysis of PVT data collected from many Iraqi fields.
In this study, the solution gas-oil ratio was taken as a function of bubble point pressure, stock tank oil gravity, reservoir pressure, reservoir temperature and relative gas density.
The construction of the new correlation is depending on thirty seven PVT reports th
Films of pure Poly (methyl methacrylate) (PMMA) doped by potassium iodide (KI) salt with percentages (1%) at different thickness prepared by casting method at room temperature. In order to study the effect of increasing thickness on optical properties, transmission and absorption spectra have been record for five different thicknesses(80,140,210,250,320)µm. The study has been extended to include the changes in the band gap energies, refractive index, extinction coefficient and absorption coefficient with thickness.
The approach of green synthesis of bio-sorbent has become simple alternatives to chemical synths as they use for example plant extracts, plus green synthesis outperforms chemical methods because it is environmentally friendly besides has wide applications in environmental remediation. This paper investigates the removal of ciprofloxacin (CIP) using green tea nano zero-valent iron (GT-NZVI) in an aqueous solution. The synthesized GT-NZVI was categorized using SEM, AFM, BET, FTIR, and Zeta potentials techniques. The spherical nanoparticles were found to be nano zero-valent, with an average size of 85 nm and a surface area of 2.19m2/g. The results showed that the removal efficiency of ciprofloxacin depends on the initial pH (2.5-10),
... Show MoreIn this work, the effect of aluminum (Al) dust particles on the DC discharge plasma properties in argon was investigated. A magnetron is placed behind the cathode at different pressures and with varying amounts of Al. The plasma temperature (Te) and density (ne) were calculated using the Boltzmann equation and Stark broadening phenomena, which are considered the most important plasma variables through which the other plasma parameters were calculated. The measurements showed that the emission intensity decreases with increasing pressure from 0.06 to 0.4 Torr, and it slightly decreases with the addition of the NPs. The calculations showed that the ne increased and Te decreased with pressure. Both Te and ne were reduced by increasing
... Show MoreThe current study presents the cellar spiders genus Nita Huber & El-Hennawy, 2007 (Araneae, Pholcidae) as the first record for Iraq spider fauna, this genus represented by the species Nita elsaff Huber & El-Hennawy, 2007 were identified based on morphological characteristics and DNA sequence data. A short morphological description is also presented for cellar spiders listed in Iraq; including this species in addition to Artema Atlanta Walckenaer, 1837.
Effect of [Cu/In] ratio on the optical properties of CuInS2 thin films prepared by chemical spray pyrolysis on glass slides at 300oC was studied. The optical characteristics of the prepared thin films have been investigated using UV-VIS spectrophotometer in the wavelength range (300-1100 nm). The films have a direct allow electronic transition with optical energy gap (Eg) decreased from 1.51 eV to 1.30 eV with increasing of [Cu/In] ratio and as well as we notice that films have different behavior when annealed the films in the temperature 100oC (1h,2h), 200oC (1h,2h) for [Cu/In]=1.4 . Also the extinction coefficient (k), refractive index (n) and the real and imaginary dielectric constants (ε1, ε2) have been investigated