Background: Diabetic mellitus type ? is a metabolic disorder of diverse etiological factors, characterized by hyperglycemia resulting from an absolute deficiency of insulin affected childhood and adolescent. Some of these patients seek an orthodontic care .The orthodontist who is treating these medically compromised patients should have a working knowledge of the multitude of medically complex problems. This information will support and enable for delivery of high standards of dental care in general and orthodontic care in particular. The aim of this study was to analyze serum IgG levels and salivary secretory IgA (sIgA) levels in human dentine extract (HDE) before (T0) and 6 months after (T6) orthodontic treatment and to correlate anti-HDE autoantibodies to root resorption in well-controlled type ? diabetic patients. Materials and methods: Sixty individuals, who were attending to Al-Mustansiriya National Diabetes Center from April to October, 2012 and classified as well- controlled type ? diabetic patients (HbA1c <8.5), were participating in this study .The mean age of the whole samples was (15±1 SD ) years, thirty three of them(18 males and 15 females) were not wearing orthodontic appliance and were selected as the controls, while twenty seven of them (12 males and 15 females) were wearing orthodontic appliance . Periapical radiographs of the upper central incisors , unstimulated saliva and serum samples were obtained of all patients before(T0) and 6 months after(T6) orthodontic treatment. Anti-dentine antibody (Ab) levels were determined by mean of enzyme linked immune sorbant assay (ELISA) technique. At T6, root resorption was classified as grade 0 (no resorption), grade 1 (slight resorption), and grade 2 (moderate to severe resorption). Chi square test and T- test were used to assess the association between qualitative and quantitative results respectively ,while paired t- test was used to analyze the results before(T0) and 6 months after(T6) orthodontic treatment. Differences were considered significant at P<0.05. Results: There was statistical significant difference in the level of (anti- dentine Ab) in saliva between the two study groups at T0 and T6, its level was higher in the wearing group comparing with non wearing group, while it didn’t differ in serum. In the wearing group, the level of anti -dentine antibody in serum and saliva significantly decreased at T6 comparing with its level at T0. High level of the (anti -dentin Ab) shown in serum and saliva in grade 1 root resorption (R1) comparing with grade 0 root resorption (R0) at T0 and also at T6. Conclusions: The results of this study indicate that the anti -dentin antibody plays an important role in the detection of root resorption during orthodontic treatment in well- controlled diabetic patients type ? and its level is different according to the grade of root resorption in both saliva and serum.
Background: Due to the variations in tooth anatomy and size among different populations, this study aimed to compare the mesiodistal width of primary second molars in Iraqi children with the mesiodistal width of stainless-steel crowns from different companies. Materials and Methods: This cross-sectional study was conducted on 220 intact maxillary and mandibular primary second molars selected from boys and girls’ Iraqi children aged 8-9 years collected from different primary schools in Baghdad city. The mesiodistal dimensions of the selected teeth and the available maxillary and mandibular stainless-steel crowns from three different companies were measured by using a 3-D scanner, and then the whole measurements were calculated usin
... Show MoreSpectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.
... Show MoreAs a result of rapid industrialization and population development, toxic chemicals have been introduced into water systems in recent decades. Because of its excellent efficiency and simple design, the three-dimensional (3D) electro-Fenton method has been used for the treatment of wastewater. The goal of the current study is to explore the efficiency of phenol removal by the 3D electro-Fenton process, which is one of the advanced oxidation processes (AOPs). In the present work, the effect of the addition of granular activated carbon (GAC) particles to the electro-Fenton system as the third electrode would be investigated in the presence of graphite as the anode and nickel foam as the cathode, which is the source of electro-generated hydrogen
... Show MoreLow-temperature stratification, high-volumetric storage capacity, and less-complicated material processing make phase-changing materials (PCMs) very suitable candidates for solar energy storage applications. However, their poor heat diffusivities and suboptimal containment designs severely limit their decent storage capabilities. In these systems, the arrangement of tubes conveying the heat transport fluid (HTF) plays a crucial role in heat communication between the PCM and HTF during phase transition. This study investigates a helical coil tube-and-shell thermal storage system integrated with a novel central return tube to enhance heat transfer effectiveness. Three-dimensional computational fluid dynamics simulations compare the proposed d
... Show MoreSeveral stress-strain models were used to predict the strengths of steel fiber reinforced concrete, which are distinctive of the material. However, insufficient research has been done on the influence of hybrid fiber combinations (comprising two or more distinct fibers) on the characteristics of concrete. For this reason, the researchers conducted an experimental program to determine the stress-strain relationship of 30 concrete samples reinforced with two distinct fibers (a hybrid of polyvinyl alcohol and steel fibers), with compressive strengths ranging from 40 to 120 MPa. A total of 80% of the experimental results were used to develop a new empirical stress-strain model, which was accomplished through the application of the parti
... Show MoreRestoration of degraded lands by adoption of recommended conservation management practices can rehabilitate watersheds and lead to improving soil and water quality. The objective was to evaluate the effects of grass buffers (GBs), biomass crops (BCs), grass waterways (GWWs), agroforestry buffers (ABs), landscape positions, and distance from tree base for AB treatment on soil quality compared with row crop (RC) (corn [
This paper presents an experimental study for strengthening existing columns against axial compressive loads. The objective of this work is to study the behavior of concrete square columns strengthening with circulation technique. In Iraq, there are significantly more reinforced rectangular and square columns than reinforced circular columns in reinforced concrete buildings. Moreover, early research studies indicated that strengthening of rectangular or square columns using wraps of CFRP (Carbon Fiber Reinforced Polymer) provided rather little enhancement to their load-carrying capacity. In this paper, shape modification technique was performed to modify the shape (cross section) of the columns from square columns into circular colu
... Show MoreConcrete columns with hollow-core sections find widespread application owing to their excellent structural efficiency and efficient material utilization. However, corrosion poses a challenge in concrete buildings with steel reinforcement. This paper explores the possibility of using glass fiber-reinforced polymer (GFRP) reinforcement as a non-corrosive and economically viable substitute for steel reinforcement in short square hollow concrete columns. Twelve hollow short columns were meticulously prepared in the laboratory experiments and subjected to pure axial compressive loads until failure. All columns featured a hollow square section with exterior dimensions of (180 × 180) mm and 900 mm height. The columns were categorized into
... Show More