Background: Postoperative morbidity after extraction of the impacted mandibular third molar (IMTM) is inevitable. One of the most common postoperative complication is alveolar osteitis (AO) which is a painful non healed socket. Many researches were attempted to prevent the occurrence of AO by introducing and applying a new materials inside the extraction socket. Platelet rich fibrin (PRF) is a biological complex fibrin matrix where autologous platelets and leucocytes are present, used to enhance tissue healing process and reduce the early adverse effects of the inflammation. Aims: To evaluate the effect of PRF on the incidence of AO. Also to assess PRF effect on pain, swelling, and trismus following the surgical removal of IMTM and compare it with the control group. Materials and methods: This clinical prospective study was conducted from October 2016 to October 2017 at the Department of Oral & Maxillofacial Surgery, College of dentistry/University of Baghdad; and Al-Sadr Specialized Health Center. A total number of 50 IMTMs were surgically removed from 45 patients who met the inclusion criteria (21 males and 24 females) with age ranged from 16-41 years. The cases were divided into two groups: a study group (25 cases) where PRF were placed inside the extraction socket and control group (25 cases) where traditional surgery were performed. AO, trismus and swelling were assessed at the 2nd and 7th postoperative day. Pain scored by numeric rating scale daily by the patients. Results: The study showed that age, gender, side of impaction, oral hygiene condition, impacted tooth classification, surgical difficulty, and the time of procedure in both control and study groups had nearly similar distribution with non- significant difference. At the 1st follow up period: Trismus (P-value = 0.834) and Swelling (P-value = 0.592) were non- significant between the two groups. AO had overall incidence of 4% occurred only in the control group, while the PRF group had no occurrence (0%), but the difference was statistically non significant. Postoperative pain had no significance difference in both groups. At the 2nd follow up period there was no significant difference regarding trismus, swelling, and incidence of AO between both groups. Conclusion: Local application of PRF can reduce the incidence of AO but not to a significant level. PRF had no effect concerning postoperative pain, swelling, and trismus.
APDBN Rashid, Southern African Linguistics and Applied Language Studies, 2023
In most manufacturing processes, and in spite of statistical control, several process capability indices refer to non conformance of the true mean (µc ) from the target mean ( µT ), and the variation is also high. In this paper, data have been analyzed and studied for a blow molded plastic product (Zahi Bottle) (ZB). WinQSB software was used to facilitate the statistical process control, and process capability analysis and some of capability indices. The relationship between different process capability indices and the true mean of the process were represented, and then with the standard deviation (σ ), of achievement of process capability value that can reduce the standard deviation value and improve production out of theoretical con
... Show MoreThe internet of medical things (IoMT), which is expected the lead to the biggest technology in worldwide distribution. Using 5th generation (5G) transmission, market possibilities and hazards related to IoMT are improved and detected. This framework describes a strategy for proactively addressing worries and offering a forum to promote development, alter attitudes and maintain people's confidence in the broader healthcare system without compromising security. It is combined with a data offloading system to speed up the transmission of medical data and improved the quality of service (QoS). As a result of this development, we suggested the enriched energy efficient fuzzy (EEEF) data offloading technique to enhance the delivery of dat
... Show MoreThe objective of this work is to investigate the performance of a conventional three phase induction motor supplied by unbalanced voltages. An effort to study the motor steady state performance under this disturbance is introduced. Using per phase equivalent circuit analysis with the concept of symmetrical components approach, the steady state performance is theoretically calculated. Also, a model for the induction motor with the MATLAB/Simulink SPS tools has been implemented and steady state results were obtained. Both results are compared and show good correlation as well. The simulation model is introduced to support and enhance electrical engineers with a complete understanding for the steady state performance of a fully loaded induc
... Show MoreThe nanostructured MnO2 /carbon fiber (CF) composite electrode was prepared using the anodic electrodeposition process. The crystal structure and morphology of MnO2 particles were determined with X-ray diffraction and field-emission scanning electron microscopy. The electrosorptive properties of the prepared electrode were investigated in the removal of cadmium ions from aqueous solution, and the effect of pH, cell voltage, and ionic strength was optimized and modeled using the response surface methodology combined with Box–Behnken design. The results confirm that the optimum conditions to remove Cd(II) ions were: pH of 6.03, a voltage of 2.77 V, and NaCl concentration of 3 g/L. The experimental results showed a good fit for the Freundli
... Show More
