Background: An oily calcium hydroxide formulation proved over the last years to be highly efficient in promoting bone regeneration in closed defects as periapical lesions, cysts, or post-extraction defects. The aim of the present study is the assessment of the outcome of treatment of deep intrabony periodontal defects with an Open Flap Debridement) (OFD) + combination of {(30% Hydroxyapatite HAp + 70% ?-Tricalcium Phosphate granules mixed with an Oily Calcium Hydroxide Suspension (OCHS )} and compare the results with {(OFD) alone)}. The combination of OCHS& TCP was used in humans with a sort of positive results, and more conduction of studies was recommended. Material and method: The sample of this study composed of sixteen patients; each had at least two intrabony defect teeth. For each patient, one tooth was treated by OFD only (control group 16 teeth) and the other teeth (study group 16 teeth) were treated with OFD + a mixture of (OSTEON II- Korea) granules comprise of (30% Hydroxyapatite HAp + 70% ?-Tricalcium Phosphate) and OCHS (Osteoinductal®, Osteoinductal GmbH., Muenchen, Germany). The clinical parameters that were measured and recorded included (Plaque index PLI, Gingival index (GI), Gingival recession(GR) , Bleeding on probing (BOP), probing pocket depth (PPD), clinical attachment level (CAL) and radiographical width & depth of the bony defect. These parameters were recorded before treatment (base line) & six months after the treatment. Results: The results after treatment revealed a highly significant reduction in all of the parameters except the PLI in both study & control groups compared to baseline (p < 0.001). The clinical results were indicated that the study group showed significant reductions of PPD and CAL mean values more than improvements obtained by the control group with significant difference (p < 0.05). Conclusions: An excellent postoperative improvement in clinical parameters was noticed in the study group more than control group and the differences were significant. Thus the present study has revealed that the treatment modality of OFD + a combination of granules comprise of (30% Hydroxyapatite HAp + 70% ?-Tricalcium Phosphate) mixed with oily Calcium Hydroxide suspension is successful, predictable and more beneficial than (open flap debridement) (OFD) alone in the treatment of deep intrabony periodontal defects.
Three types of extracts ( aquatic, alcoholic, and oily ) were prepared from the fruits of coconuts, and a series of chemical tests were conducted in addition to the use of the FTIR equipment to determine the active locations in the prepared extracts. The results indicated the presence of active compounds (tannins, saponins, flavonoids, turbines and steroids) in the extracts prepared from the fruits of coconuts, also the antimicrobial capability of these extracts were tested on pathogenic bacteria isolated from wounds and burns infections cases. The results proved that the concentration 80 mg/ml of the aquatic extract is the minimum inhibitory concentration for the microbes: Proteus vulgaris and Pseudomonas fluorescence, while the
... Show MoreA general mathematical model for a fixed bed immobilized enzyme reactor was developed to simulate the process of diffusion and reaction inside the biocatalyst particle. The modeling and simulation of starch hydrolysis using immobilized
Background: Sex variations in coronary artery disease (CAD) are well documented. However, sex differences in coronary artery calcium (CAC) and its role in the detection of coronary artery stenosis remain controversial. Objective: To assess the impact of sex variation on coronary artery calcification and its efficacy in predicting coronary artery stenosis. Methods: This is a cross-sectional observational study including 230 consecutive patients with suspected CAD (120 men and 110 women) referred for coronary computed tomography angiography (CCTA). The study analyzed sex-based differences in the sensitivity and specificity of coronary artery calcification (CAC) for detecting moderate to severe stenosis across various coronary arteries
... Show MoreThis research includes theoretical and evaluation design of a polarizer filter of high transmission in the near IR region of (900-1200nm) for different incidence angles to obtain a long wave and short wave pass filter using analytical calculations. Results refer to a new configuration design in fewer layers than used in previous studies in the long wave pass at incidence angles (45o,50o,55o). Adopted Hafnium dioxide (HfO2) and Magnesium fluoride (MgF2) as coating material at design wavelength (933nm), the study also included design short wave pass polarizer by using the same coating material.
Objective: To compare the radiological and functional outcomes of patients of Comminuted intraarticular distal radius fractures treated with or without bone marrow injection along with external fixator ligamentotaxis. Methodology: This prospective comparative study on 41 patients with comminuted intra-articular lower end radius fractures distributed patients randomly into two groups depending on whether an aspirate of bone marrow was injected at the fracture site two weeks after fracture management with external fixation ligamentotaxis. Results: The mean age was 35.8 years, with male predominance. The radiological parameters (radial height, radial inclination, and volar tilt) at the 6th month follow up were lower in the group who did not re
... Show MoreWet granulation method was used instead of conventional pan coating or fluidized –bed coating technique to prepare enteric-coated diclofenac sodium granules, using ethanolic solution of EudragitTM L100 as coating, binding and granulating agent .Addition of PEG400 or di-n-butyl phthalate as a plasticizer was found to improve the enteric property of the coat.
Part of the resulted granules was filled in hard gelatin capsules (size 0), while the other part was compressed into tablets with and without disintegrant.
The release profile of these two dosage forms in 0.1N HCl (pH 1.2)for 2 hours, and in phosphate buffer (pH 6.8) for 45 minutes as well as the release kinetic were compared with that of the en
... Show More