Background: The purpose of this study is to investigate the relationship between the roots of the maxillary posterior teeth and the maxillary sinus using spiral computed tomography, and measured the distances between the roots of the maxillary posterior teeth and the sinus floor. Materials and Methods: The sample of the present study was a total of 120 Iraqi subject (60 males & 60 females) aged (20-60) years old, who admitted to spiral Computed Tomography scan unit in AL-Zahraa hospital in AL-Kut city to have Computed Tomography scan of the brain and paranasal sinuses who had complaints of headaches or with suspicion of sinusitis but without pathological findings in maxillary sinuses. From November 2012 to April 2013, CT sagittal reconstructed images were used in this study, Images were classified according to the relation between the root apices and the maxillary sinus floor into type1: Root apices below the sinus floor, type 2: Root apices in cosines floor. Vertical distance were measured between the deepest point of the maxillary sinus floor and the root apices of the maxillary first and second premolars and first, second molar contact with the sinus floor) and type 3: Root apices penetrate or inside the r using built-in measurement tools. Means, standard deviations and minimum and maximum values were calculated for all right and left premolars and molars. t-tests were used to compare measurements between left and right sides and between female and male patients. Results: The distance between sinus floor and root apex was longest for the first premolar palatal root apex and shortest for the second molar mesoibuccal root apex for both right and left sides. No statistically significant differences were found between the right and left side measurements or between females and males patients. Conclusion: There was no significant difference in vertical relation of maxillary posterior teeth to floor of maxillary sinus between male and female and between right and left side. The mesiobuccal root of the maxillary 2nd molar was closest to the maxillary sinus floor and palatal root of 1st premolar was farthest to the sinus floor.
Determining risk indicators for dental implants is an essential strategy for preventing peri-implant diseases and effective diagnosis of dental implant success. To investigate the impact of certain potential factors on the osseointegrated dental implant. Eighty-four individuals were included in our study, 50 cases as a patient’s group and 34 participants as a control group. All cases were diagnosed based on certain criteria, 30 (60%) of patients had peri-implantitis, 20 (40%) with severe periimplantitis, 36(72%) were generalized, and 15 (30%) as localized peri-implantitis cases. The study has indicated that 44.7% of dental implants were in the anterior maxilla, followed by (27.3%) posterior maxilla, (17.4%) posterior mandible, and (10.4%)
... Show MoreThis research includes the synthesis of some new N-Aroyl-N \ -Aryl thiourea derivatives namely: N-benzoyl-N \ -(p-aminophenyl) thiourea (STU1), N-benzoyl-N \ -(thiazole) thiourea (STU2), N-acetyl-N ` -(dibenzyl) thiourea (STU3). The series substituted thiourea derivatives were prepared from reaction of acids with thionyl chloride then treating the resulted with potassium thiocyanate to affored the corresponding N-Aroyl isothiocyanates which direct reaction with primary and secondary aryl amines, The purity of the synthesized compounds were checked by measuring the melting point and Thin Layer Chromatography (TLC) and their structure, were identified by spectral methods [FTIR,1H-NMR and 13C-NMR].These compounds were investigated as a
... Show MoreRetreatment Efficacy of Continuous Rotation Versus Reciprocation Kinematic Movements in Removing Gutta-Percha with Calcium Silicate-Based Sealer: SEM Study, Raghad Noori Nawaf*, Ra
The current issues in spam email detection systems are directly related to spam email classification's low accuracy and feature selection's high dimensionality. However, in machine learning (ML), feature selection (FS) as a global optimization strategy reduces data redundancy and produces a collection of precise and acceptable outcomes. A black hole algorithm-based FS algorithm is suggested in this paper for reducing the dimensionality of features and improving the accuracy of spam email classification. Each star's features are represented in binary form, with the features being transformed to binary using a sigmoid function. The proposed Binary Black Hole Algorithm (BBH) searches the feature space for the best feature subsets,
... Show MoreThe peristaltic transport of power-law fluid in an elastic tapered tube with variable cross-section induced by dilating peristaltic wave is studied. The exact solution of the expression for axial velocity, radial velocity, stream function, local shear stress, volume of flow rate and pressure gradient are obtained under the assumption of long wavelength and low Reynolds number. The effects of all parameters that appear in the problem are analyzed through graphs. The results showed that the flux is sinusoidal in nature and it is an increasing function with the increase of whereas it is a decreasing function with the increase of . An opposite behavior for shear strain is noticed compared to pressure gradient. Finally, trapping p
... Show MoreAbstract
Objectives: This study aimed to evaluate the effectiveness of an educational program on nurses' practices concerning therapeutic communication.
Methodology: A quasi experimental design was carried out at Karbala Center for Cardiac Diseases and Surgery, Imam Hussein Medical City and Al-Handia General Hospital for period 10th June 2017 to the 15th of August 2018.
The program and instruments were constructed and developed by the researcher to measure the purpose of the study. Purposive sample comprised of (57) nurses were divided into two groups, study and control groups. The questionnaire consisted from two parts, first part is related to nurses' demographic characteristics and second part which include practices checkl