Background: Pain and the usage of local anesthetic agents are still real problem in pediatric dentistry, for these reasons, the use of minimal invasive dentistry (MID) in regard to the patient comfort is important especially for children, anxious and uncooperative patients. Chemomechanical caries removal (CMCR) methods involve the selective removal of the carious dentine hence it avoided the painful removal of the sound dentine and the anxiety resulted due to the vibration of the hand piece which is also decreased thus it appears to be more acceptable and comfortable to the patient. Aims of this study: This study was conducted among group of children to assess and compare the anxiety rating scale (during and after treatment) between the use of a recent chemomechanical caries removal method (by using Brix 3000) and the use of rotary instruments (using the ceramic bur). Materials and methods: Thirty pediatric patients aged between 8-12years, with bilateral occlusal carious permanent molars (extending into dentin) were selected for this study. Carious lesions were removed using Brix 3000 (CMCR) on one side and rotary instruments on the contra lateral side. Both cavities were restored with light cured composite filling. Anxiety scores were determined using Frankle rating scale (1962) during and after the period of caries removal. Results: The anxiety rating scale during the period of treatment showed the percentage of the negative behavior in the CMCR method was less than the percentage of the ceramic bur reverse the positive and definitely positive, which means that the new CMCR agent (Brix 3000) was more comfortable than the conventional rotary instrument (ceramic bur), that reduced the need for local anesthesia and the use of the drill. While after the treatment there is no big difference in the acceptance of the patients in two groups. Conclusion: Brix 3000 gel as a CMCR is an effective alternative method for caries removal, which appears to be more comfortable for the patients and more conservative
Background: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um part
... Show MoreShiranish formation has been divided into two microfacies units: 1-Marly biowacke stone facies 2-Biogenic pack stone facies These microfacies reflected marine deep shelf margin in the upper part of the formation, the lower part was deeper. 238 slides were investigated depending on Mineralogical, compositional and Biological processes, which reflect deep shelf margin at upper part of the formation, but at the lower part open sea environment. The age of the formation is estimated depending on the recognized biostratigraphic zone using the index fossils to be Upper- Middle Maestrichtian.
Objective: The objective of the study was to test the hypothesis, that umbilical cord blood crude serum applied topically with its high concentration of growth factors may promote an early healing for animal models with burn injury.
Methods: Fresh human umbilical cord blood UCBS was collected and screened for transmitted diseases such as hepatitis B, hepatitis C and HIV. Mice and rabbits were scalded by boiling water and chemical burning by NaOH, then treated with UCBS. In comparison with a Cetrimide treated group and a control group (without treatment). The UCBS was subjected to microbial testing to demonstrate the presence or absence of extraneous viable contaminating microorganisms.
... Show MoreA lower extracellular pH is one of the few well-documented physiological differences between tumour and normal tissues. On the other hand, elevated glutathione (GSH) level has been detected in many tumours compared with healthy surrounding tissues. The compound II: 3-(9H-purin-6-yl-thio) carbonothionyl methyl-8-oxo-7-(2-thiophen-2-yl) acetamido-5-thia-1-azabicyclo-4-octo-ene-carboxylic acid was a cephalothin derivative contain 6-mercaptopurine (6-MP). Compound II react with general base catalysis in slightly acidic pH or with sulfhydryl nucleophiles to release the chemotherapeutic drug 6-MP. The generation of compound II was accomplished following multistep reaction procedures. The structure of compound II and its intermediate was confir
... Show MoreThis work aimed PVA nanofibers in a range of concentrations were successfully manufactured via electrospinning. PVA NFs/Si was effectively prepared using the electrospinning process. The structural, morphological, optical and electrical properties of the prepared PVA were studied using XRD, FE-SEM, UV-Vis spectrophotometer and I-V characteristics, respectively. The amorphous structure of PVA nanofibers was observed. The optical energy gap from ultraviolet to visible was between (2.75 and 2.41) eV, making this compound highly sensitive to visible orange light at 610 nm, with a photosensitivity of 66%. The optical energy gap of PVA/Si heterojunction was utilized to modify this film from the UV to the visible spectrum. As show in the results,
... Show MoreThe aim of this paper, is to study different iteration algorithms types two steps called, modified SP, Ishikawa, Picard-S iteration and M-iteration, which is faster than of others by using like contraction mappings. On the other hand, the M-iteration is better than of modified SP, Ishikawa and Picard-S iterations. Also, we support our analytic proof with a numerical example.
The grasping stability of robotic manipulators is crucial to enable autonomous manipulation in an environment where robots are facing obstacles in their route, where abrupt changes in the robot’s speed are induced. These speed variations will produce forces affecting the robotic manipulator, hence its grasping stability. In this research, the grasping stability of a robotic manipulator that functions according to a frictional self-locking mechanism is investigated statically and dynamically. Both theoretical and experimental results showed that the grasped object size, weight, and its orientation inside the gripper have a great effect on grasping stability. Both the theoretical and experimental results indicated that the grasping object p
... Show MoreThe sensors based on Nickel oxide doped chromic oxide (NiO: Cr2O3) nanoparticals were fabricated using thick-film screen printing of sol-gel grown powders. The structural, morphological investigations were carried out using XRD, AFM, and FESEM. Furthermore, the gas responsivity were evaluated towards the NH3 and NO2 gas. The NiO0.10: Cr2O3 nanoparticles exhibited excellent response of 95 % at 100oC and better selectivity towards NH3 with low response and recovery time as compared to pure Cr2O3 and can stand as reliable sensor element for NH3 sensor related applications.
The research aims to evaluate Evaluation of the investments Iraqi fund for External development through the application of financial tools to a number of companies of the Iraqi Fund for External Development, and from the point of view to achieve the best returns from investment and the feasibility of the investments of the Iraqi Fund for External Development and the research community represents the Iraqi Fund for External Development and the amount of (28) A company, while the research sample is (4) companies (the Arab Petroleum Transportation Services Company, the Arab Iraqi Company for Livestock Development, the Bauhaus Company for prefabricated buildings and mineral installations, the Arab Fisheries Company) that were chosen
... Show More