Preferred Language
Articles
/
jbcd-259
Clinical evaluations for the masticatory efficiency of heat cure resin and flexible types of denture base materials
...Show More Authors

Background: The aim of this study was for estimation and comparism of masticatory efficiency in patient wearing heat cured acrylic and flexible base partial denture, finding out the role of peanuts and carrots on the measurement of chewing efficiency, and to find out whether the types of P.D. (being single or two opposing each other) has any effect on the masticatory performance. Materials and methods: Twenty partially edentulous patients were selected. Five of these patients were selected having Kennedy class I with no modification against natural dentition, other 5patients having Cl.I against Cl.I . The other 5 patients having Cl.III against natural dentition and the last 5 patients were with Cl.III against Cl.III. several ways were used for measuring masticatory efficiency including: number of chewing strokes, number of swallows, the mastication time, and measure the masticatory performance by sieving method. Differences between the means of the four groups were analyzed with t-test. Results: The differences between the two denture base types in total number of strokes was significant at (p<0.001) in study group (2,3,4), the study group (4)have the highest mean value of the total number of strokes for acrylic denture during chewing carrots food types(47.6)strokes. The highest mean value of the total chewing time is for the fourth group with the acrylic denture during chewing carrots (35.2 sec.), and the highest masticatory performance index was for the flexible denture in all study groups during chewing the two tested food. Conclusion: The flexible partial denture provide better chewing efficiency than heat cure acrylic partial denture, the masticatory performance was higher for flexible partial denture than heat cure acrylic partial denture, there was significant differences between carrots and peanuts in both flexible and heat cure acrylic partial denture, and patient with single denture show better chewing efficiency than patient with paired denture.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 27 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Experimental study of natural convection heat transfer on an enclosure partially filled porous medium heated from below by constant heat flux
...Show More Authors

This study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperatu

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Al-khwarizmi Engineering Journal
The Effect of the Solution Heat Treatment on the Mechanical Properties of Aluminum-Copper Alloy (2024-T3) Using Rolling Process
...Show More Authors

The effect of solution heat treatment on the mechanical properties of Aluminum-Copper alloy. (2024-T3) by the rolling process is investigated. The solution heat treatment was implemented by heating the sheets to 480 C° and quenching them by water; then forming by rolling for many passes. And then natural aging is done for one month. Mechanical properties (tensile strength and hardness) are evaluated and the results are compared with the metal without treatment during the rolling process. ANSYS analysis is used to show the stresses distribution in the sheet during the rolling process.  It has been seen that good mechanical properties are evident in the alloy without heat treatment due to the strain hardening and also the mechanical

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Current Research In Microbiology And Biotechnology
Detection of some Physiological and Immunological parameters in Iraqi clinical and subclinical hypothyroid patients: Relationship study
...Show More Authors

The present study was performed to evaluate the level of some risk factors (biochemical and immunological) in hypothyroid Iraqi patients considering the different thyroid functional states (hypothyroidism and subclinical hypothyroidism).The study includes 82 patients clinically diagnosed with hypothyroidism. Three study groups have been investigated: (47 clinical hypothyroid patients, 12 subclinical hypothyroid patients 23 healthy individuals) of different ages. This study, show that the proportion of females (83.3 %), (87.2%) in subclinical and clinical hypothyroidisim respectively higher than the proportion of males (16.7%),(12.8%) in subclinical and clinical hypothyrodism respectively of the total patients.The majority of subclinical hyp

... Show More
Publication Date
Thu Jan 21 2010
Journal Name
Iraqi Journal Of Veterinary Medicine
Production and Partial Purification of Heat-Stable Enterotoxin (A) Produced by Enterotoxigenic Escherichia coli
...Show More Authors

A total of (25) stool samples were collected from children and adults (2- 4) years old suffering from diarrhea to isolate E. coli strains that produce heat-stable enterotoxin a (STa), and after performing microscopic examination, cultural characterization and biochemical identification only (11) isolates showed positive E. coli. STa activity was estimated by using suckling mouse assay (SMA) and from these (11) isolates only (5) showed STa activity and the one with the highest STa activity was selected for large scale production of STa, which was followed by partial purification using ion-exchange chromatography (normal phase) using DEAE sephadex A-50 column. After purification and determination of protein concentration by using the standard

... Show More
Publication Date
Sat Nov 09 2019
Journal Name
Biochem. Cell. Arch.
EFFECT OF HEAT EXPOSURE AND GINSENG EXTRACT ON BLOOD CELLS COUNT IN BROILER CHIKS
...Show More Authors

The current study was conducted on 504(Ros-308) broiler chicks reared in Animal farms belong to College of Agriculture, University of Baghdad during the period 28/9/2017- 9/11/2018 to determine the effect of ginseng additive on the performance of chicks. Results of study showed a significant effect (p≤0.05) of exposure period an Red blood cells, 3.56×106ml3 of blood was in bird, which exposure to 2hr at heat shock. In 42 day at age 106 ×38 ml3 of blood can noticed in the blood at birds, which exposure to 2hr in 21-42 days at 3 days of age. No significant effect at ginseng on blood cells. The results showed a significant effect (p≤0.05) of interaction on red blood cells at 21 and 42 days of age and the average cells between these ages

... Show More
Preview PDF
Publication Date
Thu Jul 01 2021
Journal Name
Applied Thermal Engineering
Consecutive charging and discharging of a PCM-based plate heat exchanger with zigzag configuration
...Show More Authors

View Publication
Scopus (76)
Crossref (70)
Scopus Clarivate Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Evaluation of Convective Heat Transfer and Natural Circulation in an Evacuated Tube Solar Collector
...Show More Authors

The evacuated tube solar collector ETC is studied intensively and extensively by experimental and
theoretical works, in order to investigate its performance and enhancement of heat transfer, for Baghdad climate
from April 2011 till the end of March 2012. Experimental work is carried out on a well instrumented collector
consists of 16 evacuated tubes of aspect ratio 38.6 and thermally insulated tank of volume 112L. The relation
between convective heat transfer and natural circulation inside the tube is estimated, collector efficiency, effect of
tube tilt angles, incidence angle modifier, The solar heating system is investigated under different loads pattern (i.e
closed and open flow) to evaluate the heat loss coefficient

... Show More
View Publication Preview PDF
Crossref (17)
Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-khwarizmi Engineering Journal
Effect of Solid Particle Properties on Heat Transfer and Pressure Drop in Packed Duct
...Show More Authors

This work examines numerically the effects of particle size, particle thermal conductivity and inlet velocity of forced convection heat transfer in uniformly heated packed duct. Four packing material (Aluminum, Alumina, Glass and Nylon) with range of thermal conductivity (from200 W/m.K for Aluminum to 0.23 W/m.K for Nylon), four particle diameters (1, 3, 5 and 7 cm), inlet velocity ( 0.07, 0.19 and 0.32 m/s) and constant heat flux ( 1000, 2000 and 3000 W/ m 2) were investigated. Results showed that heat transfer (average Nusselt number Nuav) increased with increasing packing conductivity; inlet velocity and heat flux, but decreased with increasing particle size.Also, Aluminum average Nusselt number is about (0.85,2.

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 30 2026
Journal Name
Modern Sport
Design and Standardization of a Composite Test to Measure Basic Basketball Shooting Types among University Student-Players
...Show More Authors

Tests in the sports field constitute an essential tool for achieving optimal results and evaluating player performance, particularly in competitive sports such as basketball. The importance of shooting emerges as it is the only means of direct scoring and the critical statistic that distinguishes victory from defeat. The researchers observed that previous tests of basic shooting types whether administered individually or in combination do not adequately reflect the complexities of actual game situations. Therefore, the problem lies in the need to address this gap by designing a composite test that simulates various playing conditions related to basic shooting skills. The descriptive approach was adopted, and the research community was delib

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Aug 25 2026
Journal Name
Journal Of Baghdad College Of Dentistry
An evaluation of the influence of different finishing lines on the fracture strength of full contour zirconia CAD/CAM and heat press all-ceramic crowns
...Show More Authors

ABSTRACT Background: One of the major problems of all ceramic restorations is their probable fracture against the occlusal forces. The objective of this in vitro study was to evaluate the effect of two gingival finishing lines (90°shoulder and deep chamfer) on the fracture resistance of full contour CAD/CAM and heat press all-ceramic crowns. Materials and Methods: Thirty two maxillary first premolars were prepared to receive full contour CAD/CAM (zolid) and heat press (Cergo Kiss) ceramic crowns using a special paralleling device (Parallel-A-Prep). The teeth were divided into four groups according to the type of finishing line prepared. Each crown was cemented to its corresponding tooth using self-etch, self-adhesive dual cure resin ceme

... Show More
View Publication Preview PDF