Background: lip lengthening procedure is one of the surgical options for the correction of gummy smile in patients with short upper lip. Methods: A comparative clinical study was conducted on 15 patients requiring lip lengthening procedure for the esthetic correction of excessive gingival exposure with gummy smile. Scalpel was used in seven patients and diode laser in the remaining eight patients. Under infiltration anesthesia, about one cm strip of mucosa was excised at the vestibular depth and the mucosa of the lip was sutured to the alveolar mucosa. Results: The diode laser group demonstrated less postoperative pain and swelling. Regarding postoperative ecchymosis, three patients in the scalpel group developed ecchymosis and no cases were noted in the laser group, the difference was statistically significant. No patient in the laser group developed wound dehiscence and only one patient in the scalpel group had wound dehiscence at third postoperative day. Observed at one month postoperatively, the laser treated groups had less obvious scar than the scalpel group. Conclusion: Diode laser is a valuable tool in performing lip lengthening for gummy smile.
Temporomandibular Disorders (TMD) refer to a group of symptoms where pain is the most leading cause to demand a treatment by the patient. Light therapies are of great importance at current times due to its biosafety and non-invasive quality when used for the management of TMD symptoms. This study aimed to evaluate the efficacy of red LED light with low-level LASER in treating TMD patients.
A double-blind randomized clinical study was conducted and included 60 patients along 3 groups (20 for e
Increasing the power conversion efficiency (PCE) of silicon solar cells by improving their junction properties or minimizing light reflection losses remains a major challenge. Extensive studies were carried out in order to develop an effective antireflection coating for monocrystalline solar cells. Here we report on the preparation of a nanostructured cerium oxide thin film by pulsed laser deposition (PLD) as an antireflection coating for silicon solar cell. The structural, optical, and electrical properties of a cerium oxide nanostructure film are investigated as a function of the number of laser pulses. The X-ray diffraction results reveal that the deposited cerium oxide films are crystalline in nature and have a cubic fluorite. The field
... Show MoreSolutions of dyes Rhodamine 6G (Rh6G) and Coumarin480(C480) were prepared at five concentrations (1x10-3, 5x10-4, 1x10-4, 5x10-5 and1x10-5) mol/l, the mixing was stirred to obtain on a homogenous solution, the(poly methyl-methacrylate) (PMMA) was solved by chloroform solvent with certain ratio, afterward (PMMA+Rh6G) and (PMMA+C480) thin films were prepared by casting method on glass block which has substrate with dimensions (7.5 x2.5)cm2, the prepared samples were left in dark place at room temperature for 24 hours to obtain uniform and homogenous thin films. UV-VIS absorption spectra, transmission spectra and fluorescence spectra were done to measure linear refractive index and linear absorption coefficient. The nonlinear optical proper
... Show MoreA huge potential from researchers was presented for enhancing the nonlinear optical response for materials that interacts by light. In this work, we study the nonlinear optical response for chemically prepared nano- fluid of silver nanoparticles in de-ionized water with TSC (Tri-sodium citrate) protecting agent. By the means of self-defocusing technique and under CW 473 nm blue laser, the reflected diffraction pattern were observed and recorded by CCD camera. The results demonstrate that, the Ag nano-fluid shows a good third order nonlinear response and the magnitude of the nonlinear refractive index was in the order of 10−7 cm2/W. We determine the maximum change of the nonlinear refractive index and the related phase shift for the mat
... Show MorePatients with renal failure in the final stages undergo the treatment by hemodialysis. Hemodialysis is used to reinstate the intracellular and extracellular fluid environment, by propagation of molecules in solution through a semipermeable membrane along an electrochemical concentration gradient. Blood catching in the dialysis machine and the recurrent phlebotomy may lead to losing about 1-3 g of iron per year. Prohepcidin hormone is an acute phase protein (type II) that plays a major role in the systemic iron irregularities as it is a mediator of anemia in inflammation and regulator of iron metabolism. This study aims to evaluate the effect of hemodialysis on iron hemostasis and its relationship with prohepcidin as an inflammatory mark
... Show MoreThe present study evaluated the anti- Helicobacter pylori IgG, IgA and the role of virulence factor of H. pylori Vacuolating associated cytotoxin gene (Vac A) as a risk factors for CAD. The levels of serum IgG and IgA was done by indirect immunofluorescent (IIF) whereas Vac A measured by enzyme linked immunosorbent assay (ELISA). Ibn Al-Bitar specialist center for cardiac surgery laboratory and Ministry of Health/ Baghdad/ Iraq, between May and October 2018. Seventy Iraqi patients with CAD were enrolled in this study, their ages ranged between 40-84 years ; and 20 individuals as a control group which was divided into 2 subgroups: 10 apparently healthy volunteers (negative control) and the other subgroup contained 10 with normal coronary art
... Show MoreIt has been revealed previously that chronic liver disease (CLD) may be associated to hormonal fluctuations. The current study, therefore, aimed to evaluate some hormones in CLD patients compared with non-CLD individuals. This case control study was conducted at Gastroenterology and Hepatology Teaching Hospital, Medical city, Baghdad, Iraq during December 2021 to May 2022. One hundred and twenty male patients with CLD (age:14-75 years) and 120 control males (age: 24-70 years) were involved in this study. Serum samples were taken from all individuals and were then analysed for many tests which included hormones (Cortisol, testosterone, prolactin, insulin and thyroid stimulating hormone TSH); biochemical analysis (Prothrombin time
... Show MoreThree hundred and fifty five patients with hepatitis were investigated in this study all cases gave negative result with HBs Ag , IgM-anti HCV , IgM-anti HEV, IgM-anti HDV and anti-HIV tests . The frequency of IgM-anti HAV was 113 and the percentage was 32 % in all ages but when these patients divided into five groups dependent on ages. The highest percentage of IgM-anti HAV was (45%) in age <10 and the percentage declined with age increase till to 9% in age >41 year.