Preferred Language
Articles
/
jbcd-2578
Assessment of Bacterial Contamination of Orthodontic Arch wire
...Show More Authors

Background: The microorganisms can impend the life of health care professional and particularly the dental practitioners. They can be transmitted by different ways like airborne and droplet transmission. The current study was carried out to identify whether the arch wires that received from the manufactures are free from microbial contamination and to determine the bacterial species attached to the arch wires. Materials and Methods: This study involved eighty samples, consisted of two types of arch wires (nitinol and stainless-steel) from four companies (3M, G&H, Jiscop, OrthoTechnology). These wires inserted in a plane tube that contains 10 -ml of (Tris [tris(hydroxymethyl)aminomethane] and EDTA (ethylenediaminetetraacetic acid) tris-EDTA and brain heart infusion (BHI) broth. A 0.1 ml was withdrawn from the tube and spread on agar plates. The control groups consist of 16 plane tube (8 tubes with tris-EDTA and other 8 tubes with (BHI). Results: Microbial sampling yielded growth from 5 of the 80 arch wires. The predominant bacteria that isolated were Bacillus spp. No growth was recovered from 75 of the samples and from controls. The bacteria were isolated by BHI reagent and no growth was observed by tris-EDTA reagent with statistically significant difference (P<0.05). The Bacillus spp. found only in the G&H and Jiscop companies, however, no statistically significant difference was found among them (P>0.05). With regard to the presence and distribution of bacteria according to the types of wires, the present results clarified that cases of contamination with Bacillus spp. were found in the nitinol arch wires with statistically significant difference (P<0.05). Conclusions: The results of the current study revealed low count of bacterial contamination in the two types of companies (G&H and Jiscop). Not all materials that received from the manufactures are free from contamination and an effective sterilization regimen is needed to avoid cross-contamination.

Scopus Crossref
View Publication
Publication Date
Mon Jan 13 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Acidity Level on Ions Released and Corrosion of Metal Orthodontic Appliances at Different Time Intervals (An In vitro Study)
...Show More Authors

ABSTRACT Background: This study measured the effects of three parameters pH value, length of immersion and type of archwire on metal ions released from orthodontic appliances. Materials and Methods: Ninety maxillary halves simulated fixed orthodontic appliances that were immersed in artificial saliva of different pH values (6.75, 5 and 3.5) during 28 day period. Three types of archwires were used: stainless steel, nickel titanium and thermal activated nickel titanium. The quantity of nickel and chromium ions was determined with the use of atomic force spectrophotometer while iron ions by spectrophotometer. Each orthodontic set was weighted two times, before the ligation and immersion in the artificial saliva and after 28 days at the end of

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 24 2024
Journal Name
Scientific Reports
Effectiveness of high-frequency vibration, cotton rolls and elastomeric wafers in alleviating debonding pain of orthodontic metal brackets: a randomized clinical trial
...Show More Authors

View Publication
Crossref
Publication Date
Tue Dec 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of ageing media on shear bond strength of metal orthodontic brackets bonded with different adhesive systems (A comparative in-vitro study)
...Show More Authors

Background: The aim of this study was to evaluate the shear bond strength (SBS) and adhesive remnant index (ARI) of different orthodontic adhesive systems after exposure to aging media (water storage and acid challenge). Materials and methods: Eighty human upper premolar teeth were extracted for orthodontic purposes and randomly divided into two groups (40 teeth each): the first group in which the bonded teeth were stored in distilled water for 30 days at 37°C, and the second group in which the bonded teeth were subjected to acid challenge. Each group was further subdivided into four subgroups (10 teeth each) according to the type of adhesive system that would be bonded to metal brackets: either non-fluoride releasing adhesive (NFRA),

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Standards
Observation of a Signal Suppressing Effect in a Binary Mixture of Glycol-Water Contamination in Engine Oil with Fourier-Transform Infrared Spectroscopy
...Show More Authors

An in-depth experimental study of the matrix effect of antifreeze (ethylene glycol) and water contamination of engine oil through FT-IR spectroscopy. With a comparison of the percent by volume concentration of contaminated fresh 15W-40 engine oil, there appeared to be a noticeable reduction in the O–H stretching signal in the infrared spectrum when ethylene glycol based antifreeze was included as a contaminant. The contaminants of distilled water, a 50/50 mixture of water and commercial ethylene glycol antifreeze, and straight ethylene glycol antifreeze were compared and a signal reduction in the O–H stretch was clearly evident when glycol was present. Doubling the volume of the 50/50 mixture as compared to water alone still res

... Show More
View Publication
Crossref
Publication Date
Mon Jan 13 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of orthodontic relapse on the proliferation of fibroblast and epithelial rests of Malassez in periodontal ligament of rat molars (A histopathological study)
...Show More Authors

Background: Relapse of previously moved teeth, is major clinical problem in orthodontics with respect to the goals of successful treatment. This study investigated the effect of orthodontic relapse on the proliferation of fibroblast and epithelial rests of Malassez cells in periodontal ligament of rat molars. Materials and Methods: Sixteen ten-week- old male Wister rats were randomly divided into four groups composed of four animals each: Group I received no orthodontic force (control). In both Group II and Group III, uniform standardized expansive springs were used for moving the maxillary first molars buccally for periods of one and three weeks respectively. The spring initially generated an average expansive force of 20 g on each side.

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 28 2021
Journal Name
Journal Of Electrochemical Science And Technology
Simultaneous Removal of Cadmium and Copper from a Binary Solution by Cathodic Deposition Using a Spiral-Wound Woven Wire Meshes Packed Bed Rotating Cylinder Electrode
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Global Pharma Technology
The role of levan produced from pseudomonas fluorescens as antipathogenic substances and phagocytic enhancer against some of bacterial isolates
...Show More Authors

Scopus (3)
Scopus
Publication Date
Mon Jan 13 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different staining materials on color stability of sapphire brackets bonded with different types of light cure orthodontic adhesives (An in vitro study)
...Show More Authors

Background: The demand for better esthetic during orthodontic treatment has increased nowadays, so orthodontists starting using esthetic arch wires, brackets and ligatures.Tooth colored brackets were introduced in different types of materials. Sapphire ceramic brackets are one type of esthetic brackets and their color stability remains the main concern for the clinicians and patients at the same time. The present study design to evaluate the effect of three different staining materials (pepsi, black tea and cigarette smoke) on the stainability of sapphire ceramic brackets bonded with three types of light cure orthodontic adhesives which include: Resilience, Enlight and Transbond. Materials and Methods: The sample consisted of three hundre

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 31 2022
Journal Name
International Journal Of Dentistry
Bond Strength Survival of a Novel Calcium Phosphate-Enriched Orthodontic Self-Etching System after Various Ageing Protocols: An In Vitro Study
...Show More Authors

Objective. This study aimed to evaluate the orthodontic bond strength and enamel-preserving ability of a hydroxyapatite nanoparticles-containingself-etch system following exposure to various ageing methods. Materials and Methods. Hydroxyapatite nanoparticles (nHAp) were incorporated into an orthodontic self-etch primer (SEP, Transbond™ plus) in three different concentrations (5%, 7%, and 9% wt) and tested versus the plain SEP (control) for shear bond strength (SBS), adhesive remnant index (ARI) scores, and enamel damage in range-finding experiments using premolar teeth. The best-performing formulation was further exposed to the following four artificial ageing methods: initial debonding, 24 h water storage, one-month water stora

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Overview of seismic performance assessment of reinforced concrete buildings
...Show More Authors

View Publication
Scopus Crossref