Preferred Language
Articles
/
jbcd-2550
Development of Sinusitis After Sinus Floor Elevation Surgery: A Systematic Review
...Show More Authors

Background: Maxillary sinusitis can arise after sinus floor elevation surgery and should be treated immediately to prevent further complications which included dental implants failure, graft lost, and oro-antral fistula. This is the first systematic review to assess the incidence, causes, and treatment of sinusitis after sinus lift surgery. Materials and methods: An electronic search included MEDLINE (PUBMED) data base site was carried out for articles involving development of sinusitis after sinus lift surgery from September 1997 up to April, 8, 2017. The search was done and reviewed by two independent authors. Results: The total results of electronic search were (182) abstracts and articles, the extracted articles which involved development of sinusitis after sinus lift surgery were (25) studies. Of the 25 articles only (8) articles fit the inclusion criteria. Maxillary sinusitis was calculated for all selected studies and it was ranged from 2.12% to 12.7% with average of 5.4 %. Conclusion: Maxillary sinusitis could be developed after sinus lift surgery with average of 5.4 % and the patients with previous maxillary sinus disease showed to be at increased risk of sinusitis after sinus lift surgery.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Acquired Error in using Antibiotic for Surgery Patients in Iraqi Hospitals
...Show More Authors

The use of antibiotics (AB) in surgery focused in either treating established infection or to prevent suspected post-operative infection. Inappropriate use of antibiotic for treatment of patients with common infections is a major problem worldwide, with great implications with regards to cost of treatment and development of resistance to the antimicrobial agent. Moreover, antibiotics may often be dispensed without a clear clinical indication. This study was conducted to estimate the medication errors in using antibiotic for surgery patients which may effect their wound healing. A 260 patients with clean-contaminated and contaminated surgery were included from two teaching hospitals, 160 patient from Medical city hospital and 100 fro

... Show More
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Thu Nov 01 2012
Journal Name
Journal Of Computer Science
VOICE ACTIVATION VISUALIZATION FOR ECHOCARDIOGRAPH AND 3D ANGIOGRAPHIC IMAGES IN SURGERY
...Show More Authors

In some cases, surgeons need to navigate through the computer system for reconfirmation patients’ details and unfortunately surgeons unable to manage both computer system and operation at the same time. In this paper we propose a solution for this problem especially designed for heart surgeon, by introducing voice activation system with 3D visualization of Angiographic images, 2D visualization of Echocardiography processed video and selected patient’s details. In this study, the processing, approximation of the 3D angiography and the visualization of the 2D echocardiography video with voice recognition control are the most challenging work. The work involve with predicting 3D coronary three from 2D angiography image and also image enhan

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Dec 16 2021
Journal Name
Journal Of Advance Research In Chemical Sciences
Study of Schiff Bases Complexes of Trimethoprim: A Review
...Show More Authors

Trimethoprim derivative Schiff bases are versatile ligands synthesized with carbonyl groups from the condensation of primary amines (amino acids). Because of their broad range of biological activity, these compounds are very important in the medical and pharmaceutical fields. Biological activities such as antibacterial, antifungal and antitumor activity are often seen. Transition metal complexes derived from biological activity Schiff base ligands have been commonly used.

View Publication Preview PDF
Publication Date
Thu Sep 16 2021
Journal Name
Journal Of Advance Research In Chemical Sciences
Study of Schiff Bases Complexes of Trimethoprim: A Review
...Show More Authors

Trimethoprim derivative Schiff bases are versatile ligands synthesized with carbonyl groups from the condensation of primary amines (amino acids). Because of their broad range of biological activity, these compounds are very important in the medical and pharmaceutical fields. Biological activities such as antibacterial, antifungal and antitumor activity are often seen. Transition metal complexes derived from biological activity Schiff base ligands have been commonly used

Publication Date
Sat Oct 16 2021
Journal Name
Journal Of Advance Research In Chemical Sciences
Study of Schiff Bases Complexes of Trimethoprim: A Review
...Show More Authors

Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
A 980nm Diode Laser Clot Formation of the Rabbit’s Dental Sockets after Teeth Extraction
...Show More Authors

The aim of this research work is to evaluate the use of 980 nm diode laser in clotting the blood
in the bone socket after tooth extraction. The objective is to prevent possible clot dislodgement which is
a defect that may lead to possible infection. A number of rabbits were irradiated using 980nm CW mode
diode laser, 0.86W power output for 9s and 15s exposure time. The irradiated groups were studied
histopathologically in comparison with a control group. Results showed that laser photothermal
coagulation was of benefit in minimizing the possibility of the incidence of postoperative complications.
The formation of the clot reduces the possibility of bleeding and infection.

View Publication Preview PDF
Publication Date
Wed Aug 27 2025
Journal Name
Al-salam Journal For Medical Science
Nanotechnology in Molecular Genetics: A literature review
...Show More Authors

Nanotechnology extends the limits of molecular diagnostics to the nanoscale. This study describes some of the details of how the body interacts with nanoparticles. Biological tests measuring the presence or activity of selected substances become quicker, more sensitive, and more flexible when certain nanoscale particles are put to work as tags. Particular emphasis is placed on the effects of surface changes on body-borne particles, their transport within the body, and the dose-response effect. Other considerations include the definition of "persistent" in the context of therapy, FDA scientific committees, and the need for nanoparticle tracking. In short, there have been dramatic changes in molecular and genetic research findings, as well as

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2024
Journal Name
Tikrit Journal For Dental Sciences
Additive Manufacturing Technologies in Dentistry (A Review)
...Show More Authors

Background: Significant advancements have been observed in the additive manufacturing (AM) technology industry in recent decades. Due to the inherent variations among each AM manufacturing technique, new areas of investigation continually arise and require consideration. Additionally, the novel applications of additive manufacturing present new difficulties and possibilities for targeted focus. The aim of this manuscript is to conduct a comprehensive literature review that describes the various processing methods, precision levels, types of materials utilized, and potential applications of 3D printing technology in the field of dentistry. Data: An online search was conducted on databases including Research Gate, Google Scholar, and

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Molar tubes and failure rates–A review
...Show More Authors

Objectives: To review the failure rates of molar tubes and the effect of molar tube base design, adhesive type, and bonding technique on the failure rates of molar tubes. Data: The revolution of molar bonding greatly impacted fixed orthodontic appliance treatment by reducing chair-side time and improving patient comfort. Even with the many advantages of molar bonding, clinicians sometimes hesitate to use molar tubes due to their failure rates. Sources: Internet sources, such as Pubmed and Google Scholar. Study selection: studies testing the bond failure rate of molar tubes. Conclusions: The failure rate of the molar tubes can be reduced and the bond strength of the molar tubes can be improved by changing the design of the molar tube base

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Sun Sep 24 2023
Journal Name
Journal Of Al-qadisiyah For Computer Science And Mathematics
Human Recognition Using Ear Features: A Review
...Show More Authors

Over the past few years, ear biometrics has attracted a lot of attention. It is a trusted biometric for the identification and recognition of humans due to its consistent shape and rich texture variation. The ear presents an attractive solution since it is visible, ear images are easily captured, and the ear structure remains relatively stable over time.  In this paper, a comprehensive review of prior research was conducted to establish the efficacy of utilizing ear features for individual identification through the employment of both manually-crafted features and deep-learning approaches. The objective of this model is to present the accuracy rate of person identification systems based on either manually-crafted features such as D

... Show More
View Publication
Crossref