Preferred Language
Articles
/
jbcd-2548
Comparative evaluation of the radiographic density of GuttaFlow® 2 in different obturation techniques using Spiral Computed Tomography
...Show More Authors

Background: Ideal root canal obturation depends on many factors; one of them is good sealing of root canal without pores. The aim of this study was to determine the radiographic density of GuttaFlow® 2 with different obturation techniques using spiral computed tomography. Materials and Methods: Forty palatal roots of permanent maxillary first molar were used in this study. Following working length determination, root canal was prepared using rotary PROTAPER universal system. They were randomly divided into four groups of 10 roots each, the groups are Conventional lateral condensation with Apexit Plus sealer, Conventional lateral condensation with GuttaFlow® 2 as a sealer, Soft Core Regular with GuttaFlow® 2 as a sealer and single cone with GuttaFlow® 2. The experimental roots were then analyzed in both horizontal and vertical sections from the apex to coronal using Spiral Computed Tomography. The obtained data were analyzed using one-way ANOVA and Tukey tests at a level of significance of 0.05. Results: Statistical analysis showed highly significant differences among the different areas (apical, middle and coronal) of each group. The density of obturation systems decreased in the following sequence: single cone with GuttaFlow® 2 (highest density), Soft Core Regular, Conventional lateral condensation with GuttaFlow® 2 as a sealer and finally Conventional lateral condensation with Apexit Plus sealer (lowest density) Conclusion: None of the tested obturation techniques can achieve ideal three-dimensional dense obturation. Single cone with GuttaFlow® 2 shows the best results.

Crossref
View Publication
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Evaluation of Trace Elements in Iraqi Patients with Rheumatoid Arthritis by using Atomic Absorption Spectrophotometer (AAS)
...Show More Authors

Zinc, Copper, Selenium, Magnesium, Manganese, Chromium, Iron, Nickel, Cobalt, Vanadium and Germanium were determined by atomic absorption spectrophotometer (AAS) in blood serum of patients with rheumatoid arthritis, (30) patients (14male and 16female) with age range (37-60) years compared with normal tensive control. The analysis of results showed that the mean value of concentration (Magnesium,  Manganese and Nickel) were significantly higher in patients with rheumatoid arthritis compared to that of healthy, while the mean levels of serum (Zinc, Copper, Selenium, Chromium, Iron, Cobalt and Germanium) were significantly lower than controls. There were no significant changes in overall mean concentration of serum Vanadium in patients

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Development and in vitro Evaluation of Bioadhesive Vaginal Tablet using Econazole Nitrate as a Model Drug
...Show More Authors

         In this study, a bioadhesive dosage form of eoconazole nitrate for vaginal delivery was designed using a combination of bioadhesive polymers: Carbopol 941 p and sodium carboxymethylcellulose or methylcellulose in different ratios. The bioadhesive strength was evaluated by measuring the force required to detach the tablet from sheep vaginal mucosal membrane. It was found that the bioadhesive force was directly proportional to Carbopol 941 p content in the different formulae. The formulae were tested for their swelling behavior using agar gel plate method. The results showed that formulae containing a combination of Carbopol 941 p and sodium carboxymethylcellulose had greater swelling index

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 08 2019
Journal Name
Digest Journal Of Nanomaterials And Biostructures
IMPROVING SENSITIVITY OF In 2 O 3 AGAINST NO 2 TOXIC GAS BY LOADING TIN OXIDE
...Show More Authors

The paper discusses the structural and optical properties of In 2 O 3 and In 2 O 3-SnO 2 gas sensor thin films were deposited on glass and silicon substrates and grown by irradiation of assistant microwave on seeded layer nucleated using spin coating technique. The X-ray diffraction revealed a polycrystalline nature of the cubic structure. Atomic Force Microscopy (AFM) used for morphology analysis that shown the grain size of the prepared thin film is less than 100 nm, surface roughness and root mean square for In 2 O 3 where increased after loading SnO 2 , this addition is a challenge in gas sensing application. Sensitivity of In 2 O 3 thin film against NO 2 toxic gas is 35% at 300 o C. Sensing properties were improved after adding Tin Oxi

... Show More
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effect of COX-2 Inhibitors Selectivity on Lipid Profile in Hyperlipidemic and Normolipidemic Type 2 Diabetics
...Show More Authors

Development of NSAIDS based on inhibiting cyclooxygenase activity. However, the different physiological consequences arrised by appearance of new drugs with different selectivity to COX-2 enzyme upon their administration with their relevant affects on some cardiovascular risk factors. To study the potential effects of relatively  diclofenac and highly specific  celecoxib COX-2 inhibitors on lipid profile and serum C-reactive protein in type 2 diabetes, whom have hyperlipidemia to be compared by their effects with normolipidemic patients. A total number of 34 type 2 diabetics (14 normolipidemics and 20 hyperlipidemics) treated with either diclofenac 100mg/day or celecoxib 200mg/day for eight weeks. Analysis  of results indi

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effects of Interleukin-2 (IL-2) and Interleukin-6 (IL-6) in Recurrent Spontaneous Abortion (RSA)
...Show More Authors

         Recurrent Spontaneous Abortion (RSA) is the most painful experience for couples expecting a child. This study aimed to determine the relevance of IL-2 and IL-6 in recurrent spontaneous abortion (RSA).  Serum samples were collected from 90 women attend Al Kadhmiya teaching hospital in Baghdad. 60 women (first group) had recurrent abortion the women were negative for rubella virus, herpes simplex virus and toxplasma gondii. And they were negative from bacterial infection eg. Niesseria gonorrhea and Chlamydia trachomatis. The histopathological tests for fetus abnormalities were negative in this group, and 30 women (second group) with successful pregnancy (normal delivery). All samples we

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 13 2023
Journal Name
International Conference Of Computational Methods In Sciences And Engineering Iccmse 2021
Management of the flood disaster and assessment their damaged areas using remote sensing and GIS techniques: A case study of Tigris River – Maysan Governorate, Iraq
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Tue Aug 30 2016
Journal Name
Mechanical Engineering
The Effect of Different Furrow Depths and Speeds of Machinary Units Using A Locally Assembled Combine Implement on Planting Maize
...Show More Authors

View Publication
Publication Date
Wed Aug 11 2021
Journal Name
International Journal Of Interactive Mobile Technologies (ijim)
Image Denoising Using Multiwavelet Transform with Different Filters and Rules
...Show More Authors

<p class="0abstract">Image denoising is a technique for removing unwanted signals called the noise, which coupling with the original signal when transmitting them; to remove the noise from the original signal, many denoising methods are used. In this paper, the Multiwavelet Transform (MWT) is used to denoise the corrupted image by Choosing the HH coefficient for processing based on two different filters Tri-State Median filter and Switching Median filter. With each filter, various rules are used, such as Normal Shrink, Sure Shrink, Visu Shrink, and Bivariate Shrink. The proposed algorithm is applied Salt&amp; pepper noise with different levels for grayscale test images. The quality of the denoised image is evaluated by usi

... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Different methods for characterizing surface roughness using laser speckle technique
...Show More Authors

In this work, results from an optical technique (laser speckle technique) for measuring surface roughness was done by using statistical properties of speckle pattern from the point of view of computer image texture analysis. Four calibration relationships were used to cover wide range of measurement with the same laser speckle technique. The first one is based on intensity contrast of the speckle, the second is based on analysis of speckle binary image,  the third is on size of speckle pattern spot, and the latest one is based on characterization of the energy feature of the gray level co-occurrence matrices for the speckle pattern. By these calibration relationships surface roughness of an object surface can be evaluated within the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Desalination And Water Treatment
Reducing endotoxin from dialysis water by using different disinfection processes
...Show More Authors

View Publication
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref