Preferred Language
Articles
/
jbcd-2548
Comparative evaluation of the radiographic density of GuttaFlow® 2 in different obturation techniques using Spiral Computed Tomography
...Show More Authors

Background: Ideal root canal obturation depends on many factors; one of them is good sealing of root canal without pores. The aim of this study was to determine the radiographic density of GuttaFlow® 2 with different obturation techniques using spiral computed tomography. Materials and Methods: Forty palatal roots of permanent maxillary first molar were used in this study. Following working length determination, root canal was prepared using rotary PROTAPER universal system. They were randomly divided into four groups of 10 roots each, the groups are Conventional lateral condensation with Apexit Plus sealer, Conventional lateral condensation with GuttaFlow® 2 as a sealer, Soft Core Regular with GuttaFlow® 2 as a sealer and single cone with GuttaFlow® 2. The experimental roots were then analyzed in both horizontal and vertical sections from the apex to coronal using Spiral Computed Tomography. The obtained data were analyzed using one-way ANOVA and Tukey tests at a level of significance of 0.05. Results: Statistical analysis showed highly significant differences among the different areas (apical, middle and coronal) of each group. The density of obturation systems decreased in the following sequence: single cone with GuttaFlow® 2 (highest density), Soft Core Regular, Conventional lateral condensation with GuttaFlow® 2 as a sealer and finally Conventional lateral condensation with Apexit Plus sealer (lowest density) Conclusion: None of the tested obturation techniques can achieve ideal three-dimensional dense obturation. Single cone with GuttaFlow® 2 shows the best results.

Crossref
View Publication
Publication Date
Sat Jul 12 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Fracture strength of laminate veneers using different restorative materials and techniques (A comparative in vitro stuy)
...Show More Authors

Background: Esthetic correction represents one of the clinical conditions that required the use of laminate veneers in premolars region. Aim of the study: The purpose of this study was to evaluate the fracture strength of the laminate veneers in maxillary first premolars, fabricated from either composite (direct and indirect techniques) or ceramic CAD/CAM blocks. Materials and Methods: Fifty sound human maxillary premolar teeth were used in this in vitro study. Teeth were divided randomly into one control group and four experimental groups of ten teeth each; Group A: Restored with direct composite veneer (Filtek Z250 XT), Group B: Restored with indirect composite veneers (Filtek Z250 XT), Group C: Restored with lithium disilicate ceramic CA

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 12 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Assessment of Sagittal Condylar Position of TMJ Dysfunction in Centric Occlusion by Using Cone Beam Computed Tomography
...Show More Authors

Background: Temporomandibular joint (TMJ) is a compound articulation formed from the articular surfaces of the temporal bone and the mandibular condyle.CBCT imaging of TMJ is that it allows accurate measurements of the volume and surface of the condyle. The aim of the study is to assess the sagittal position of mandibular condyle in patients with temporomandibulardysfunction using Cone Beam Computed Tomography in centric occlusion. Materials and Methods: CBCT images for all patients were obtained in an upright position using New Tom Giano CBCT with different field of view (11 x 8), (11 x 5), and (8 x 8) and exposure factors was changed accordingly using NNT version 5.1 software for sagittal reconstruction, anterior, superior and posterior

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Sep 01 2018
Journal Name
J Indian Soc Periodontol.
Osteoporosis effect on posterior mandible in preimplanted area for postmenopausal females using cone-beam computed tomography
...Show More Authors

Scopus (2)
Scopus
Publication Date
Thu Jan 14 2016
Journal Name
International Journal For Sciences And Technology
Evaluation of her/2-neu gene status using FISH/CISH techniques in Iraqi breast carcinoma patients
...Show More Authors

The present study aimed to examine the concordance between FISH/CISH techniques for assessment of amplification of her2neu gene in Iraqi breast carcinoma patients. Seventy four (74) Iraqi breast cancer patients were involved at the study from the Histopathology Department at the Central Public Health Laboratory in Bagdad, Iraq. Amplification of HER2neu was detected in (33.8%) by fluorescence in situ hybridization and (13.51%) showed high amplification by chromogenic in situ hybridization and (32.43%) showed low amplification. The results of chromogenic in situ hybridization were significantly correlated with the results of two-color fluorescence in situ hybridization with the same tumors. In addition, the study involved the correlation betw

... Show More
Publication Date
Fri Dec 06 2019
Journal Name
Karbala International Journal Of Modern Science
Stereo Photogrammetry vs Computed Tomography for 3D Medical Measurements
...Show More Authors

View Publication
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Mon Feb 26 2024
Journal Name
Journal Of Contemporary Medical Sciences
The Validity of Computed Tomography Guided Lung Tru- cut Biopsies in Achieving Accurate Tissue Results
...Show More Authors

Objective: This study aims to assess the efficacy of CT-guided true-cut biopsy as a less invasive and cost-effective diagnostic technique for peripherally placed lung lesions.   Methods: fourty patients with solitary lung nodule were involved in this study, true cut biopsies under Ct guide was taken then processed for routine H&E staining.   Results: different pathological features can be identified with different pathological features giving primary diagnostic screening for lung cancer   Conclusion: CT guided thoracic lesion biopsy is very efficient, cost-effective and less invasive technique when compared with the thoracic surgery

View Publication
Scopus Clarivate Crossref
Publication Date
Mon Feb 05 2024
Journal Name
J Contemp Med Sci | Vol. 10, No. 1, January–february 2024: 77–79
The Validity of Computed Tomography Guided Lung Tru-Cut Biopsies in Achieving Accurate Tissue Results
...Show More Authors

Objective: This study aims to assess the efficacy of CT-guided true-cut biopsy as a less invasive and cost-effective diagnostic technique for peripherally placed lung lesions.

Publication Date
Sat Jul 12 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The multi-detector computed tomographical analysis of bone density in impacted maxillary canines
...Show More Authors

Background: Maxillary canines are important aesthetically and functionally, but impacted canines are more difficult and time consuming to treat, the aim of this study is to investigate with multi-detector computed tomography the correlation between the bone density and the upper canine impaction. Material and method: A sample of Unilaterally impacted maxillary canines from 24 patients (19 female, 5 male) who were referred to accurately localize the impacted canines at al- Karkh general hospital were evaluated by a volumetric 3-d images by the multi-detector computed tomography to accurately measure the bone density of the maxillary cortical palate of the maxillary impacted canine side and compare it with the other side of the normally erupt

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro the Effect of Canals Instrumented with Three Rotary Ni-Ti Systems on the Dislocation Resistanceo Guttafusion ® versus Single Cone Obturation Technique
...Show More Authors

Background: Complete seal of the root canal system following its chemo-mechanical debridement plays a pivotal role for achieving successful endodontic treatment. This can be established by reducing the gaps between the core filling material and root canal wall. Aim: To assess and compare the dislocation resistance of root canals obturated with GuttaFusion® and TotalFill BC sealer versus single cone obturation technique and TotalFill BC sealer after instrumentation of the canals with WaveOne, ProTaper Next and ProTaper Universal system. Material and Method: Sixty extracted human permanent mandibular premolars were conducted in the current study. The teeth were decorated and left the root with 15mm length; the roots were divided randomly i

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 30 2006
Journal Name
Al-kindy College Medical Journal
The Use of Spiral Computerized Tomography in the Diagnosis of Middle –Third Facial Fractures as Compared to Plain Radiography
...Show More Authors

Background: Trauma is one of the most common
clinical problems that confront the maxillofacial
surgeon and radiologist alike. Middle third facial
fractures are diagnosed primarily on the bases of
clinical examination and plain radiographs than can
result in much preoperative speculation.
Objective: To assess the advantages of spiral
computerized tomography over conventional
radiography in the pre-surgical evaluation of middle
third facial fractures.
Methods: Thirty patients with thirty-eight facial
fractures were studied, all patients were examined
clinically, by plain radiography and then by spiral CT.
Results: Of the 38 middle-third fractures, 16
(42.1%) were zygomatic fractures, 8 (21.1%) were

... Show More
View Publication Preview PDF