Preferred Language
Articles
/
jbcd-253
Comparison of regional bond strength of post space of fiber-reinforced post luted with two types of cements at different testing times
...Show More Authors

Back ground: This in vitro study was carried out to investigate the effect of post space regions (coronal, middle and apical), Time and the mode of polymerization (dual, self-cured) of the cements used on the bond strength between translucent fiber post and root dentin by using push-out test. Materials and Methods: Forty eight extracted mandibular first premolars (single root) were instrumented with ProTaper Universal system files (for hand use) and obturated with gutta percha for ProTaper and AH26® root canal sealer following the manufacturer instructions, after 24 hours post space was prepared using FRC postec® plus drills no.3 creating 8 mm depth post space. The prepared samples were randomly divided into two main groups (24 samples each) according to the used cement (Group M, self-cure, Multilink N) and (Group R, dual cure, Relyx U100). Then each group was subdivided into three groups (each group contains 8 samples) according to the testing time after cementation. (g M1: push out test after 24 hour of cementation with Multilink N), (g M2: push out test after one week of cementation with Multilink N),(g M3: push out test after two weeks of cementation with Multilink N), (g R1: push out test after 24 hours of cementation with RelyxU100), (g R2: push-out test after one week of cementation with RelyxU100), (g R3: push out test after two weeks of cementation with RelyxU100). After cementation and incubation each root was sectioned horizontally into 3 slices (2 mm in thickness) represent the coronal, middle and apical regions of the post space. Push out bond strength test was performed and measured using a universal testing machine (Tinius-Olsen) at across head speed of 0.5 mm/min. Results: showed that regarding the root region, the bond strength values increased significantly apical to coronal region in both tested cements. For the effect of time, the bond strength values also significantly increased with time for both tested cements. For mode of polymerization, the self-cured resin cement Multilink N showed higher bond strength values. Conclusion: the retention of fiber post was affected by root region, mode of polymerization of the cements used and time elapsed after cementation of the post.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Enamel Surface after Debonding of Different Types of Esthetic Brackets (An In Vitro Study)
...Show More Authors

Background: Debonding orthodontic brackets and removal of residual bonding material from the enamel surface include critical steps that may cause enamel damage. The aim of the present study was to evaluate and compare the site of bond failure and enamel surface damage after debonding of three types of esthetic brackets (composite, ceramic, sapphire) bonded with light cure composite and resin-modified glass ionomer adhesive. Materials and methods: Seventy two maxillary premolars teeth were divided into three groups each group consisted of 24 teeth according to the type of brackets. Each group was subdivided into two subgroups (12 teeth for each) according to the bonding material that was used. After 7 days of bonding procedure, the brackets

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Response of composite steel-concrete cellular beams of different concrete deck types under harmonic loads
...Show More Authors
Abstract<p>This study aims to investigate the adequacy of composite cellular beams with lightweight reinforced concrete deck slab as a structural unit for harmonic loaded buildings. The experimental program involved three fixed-ends supported beams throughout 2140 mm. Three concrete types were included: Normal Weight Concrete (NWC), Lightweight Aggregate Concrete (LWAC), and Lightweight Fiber Reinforced Aggregate Concrete (LWACF). The considered frequencies were (5, 10, 15, 20, 25, and 30) Hz. It was indicated that the harmonic load caused a significant influence on LWAC response (64% greater than NWC) and lattice cracks were observed, especially at 30 Hz. As for LWACF slab, no cracks appeared, </p> ... Show More
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Oct 01 2013
Journal Name
International Journal Of Biological Macromolecules
Characterization and determination of lignin in different types of Iraqi phoenix date palm pruning woods
...Show More Authors

View Publication
Scopus (27)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Computers &amp; Electrical Engineering
Utilizing different types of deep learning models for classification of series arc in photovoltaics systems
...Show More Authors

View Publication
Crossref (15)
Crossref
Publication Date
Sun Jul 01 2018
Journal Name
International Journal Of Engineering & Technology
Influence of Percentage Replacement of Metakaolin on Different Concrete Types Exposed to Internal Sulphate Attack
...Show More Authors

This research presents an experimental investigation on the influence of metakaolin replacement percentage upon some properties of different concrete types. Three types of concrete were adopted (self- compacted concrete, high performance concrete and reactive powder concrete) all of high sulphate (SO3) percentage from the fine aggregate weight, 0.75%. Three percentages of metakaolin replacement were selected to be studied (5, 7 and 10) %. Three types of concrete properties (compressive, flexural and splitting tensile strength) were adopted to achieve better understanding for the influence of adding metakaolin.. The output results indicated that the percentage of metakaolin had a different level of positive effect on the compressive strength

... Show More
Preview PDF
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
Comparison Between Different DNA and Conventional
...Show More Authors

Background: The discriminative power of the classical WHO parameters in relation to male fertility is quite low, because they only address few aspects of sperm quality and function. This has led investigators to focus their attention on the male gamete and in particular its genome.Objective: To explore which of the sperm DNA damage parameters measured by comet assay are more reliable, and their relations with the standard semen parameters.Methods: Study was done on 40 infertile men selected from couples attending the Institute of Embryo Reasearch and Infertility Treatment at Al-Kadhimiya City/ Baghdad in the period between February 2009 and May 2009, with a history of infertility of ≥1 years; and 15 healthy volunteers of proven fertili

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Nano composites of PAM Reinforced with Al2O3
...Show More Authors

         The aim of this investigation is to determine how different weight percentages of alumina nanoparticles, including 0.02, 0.04, and 0.06 percent wt, affect the physical characteristics of Poly Acrylamide (PAAM). Using a hot plate magnetic stirrer, 10 g of poly acrylamide powder was dissolved in 90 g of di-ionized distillate water for 4 hours to produce PAAM with a concentration of 0.11 g/ml. Four sections of the resulting solution, each with a volume of 20 ml, were created. Each solution was added independently with alumina nanoparticles in different ratios 0.0, 0.02, 0.04, and 0.06 to create four nano fluid solutions with different alumina nanoparticle contents based on each weight percent. The hand casting process for n

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Different estimation methods of reliability in stress-strength model under chen distribution
...Show More Authors

View Publication
Scopus (2)
Crossref (4)
Scopus Crossref
Publication Date
Thu Jun 01 2017
Journal Name
Journal Of Huazhong University Of Science And Technology [medical Sciences]
New mini dental implant attachments versus O-ring attachment after cyclic aging: Analysis of retention strength and gap space
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Fri Jul 01 2016
Journal Name
Composite Structures
Bond behaviour between CFRP laminates and steel members under different loading rates
...Show More Authors

Carbon fibre reinforced polymers are widely used to strengthen steel structural elements. These structural elements are normally subjected to static, dynamic and fatigue loadings during their life-time. A number of studies have focused on the characteristics of CFRP sheets bonded to steel members under static, dynamic and fatigue loadings. However, there is a gap in understanding the bonding behaviour between CFRP laminates and steel members under impact loading. This paper shows the effect of different load rates from quasi-static to 300 × 103 mm/min on this bond. Two types of CFRP laminate, CFK 150/2000 and CFK 200/2000, were used to strengthen steel joints using Araldite 420 epoxy. The results show a significant bond strength enhancemen

... Show More
Scopus (74)
Crossref (62)
Scopus Clarivate Crossref