Preferred Language
Articles
/
jbcd-252
Comparison of fit among different types of post restorations luted with conventional cement
...Show More Authors

Background: with the advent of new postmaterial in dentistry, it has become important to measure fitness of post restoration along the horizontal plane of the root space.This study aimed to measure and compare, the cement film thickness of conventional zinc phosphate cement in micrometer between the post and root dentin along horizontal plane at different post space regions (coronal, middle and apical) of four types of posts, by using stereomicroscopy. Material and methods: Thirty-two extracted human maxillary canines, mandibular canines and maxillary central incisors (n=32) were instrumented with ProTaper system files (hand use) and obturated with gutta-percha for ProTaper and AH26® root canal sealer. After 24hrs of incubation at 37ºC, post space was prepared using FRC Postec® plus drills no.3 and ER Cera reamer size 70, creating 10 mm deep post space. The prepared samples were then randomly divided into four main groups (8 samples each) according to the type of post used (Group A: fabricated cast metal post), (Group B: fabricated zirconia post), (Group C: prefabricated glass fiber reinforced composite post), (Group D: prefabricated zirconia post). After cementation and incubation period of 24hrs, each root was sectioned horizontally into 3 discs (2mm in thickness) at the coronal, middle and apical regions of the root space. The cement thickness between post and root dentine was measured (in µm) by using a stereomicroscope. Results: The results of this study showed that the lowest mean of cement thickness was in group C (35.28?m), followed by group A (78.12?m) and group D (81.9?m), and all three groups demonstrated acceptable cement thickness, while group B produced unacceptable cement thickness (127.34?m). One way ANOVA test revealed a statistically highly significant difference for the cement thickness among four post types used within each region of the root. Conclusions: the root region and type of post system have an effect on cement thickness along post space.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Apr 16 2017
Journal Name
Tikrit Journal For Dental Sciences
Evaluation of Apical Transportation and Curve Straightening of Curved Root Canals after Preparation with Different Nickel - Titanium Rotary Systems (Comparative in Vitro Study)
...Show More Authors

The goals of endodontic preparation were to shape and clean the space of the root canal and remove microorganisms, affected dentin and pulp, the apical foramen and the canal curve should be protected from being transported during endodontic canal preparation. The aim of this study was to evaluate the curve straightening of curved root canals and apical transportation after preparation with four rotary systems. Forty mesial roots of the lower 1st molars teeth only the mesiobuccal canals were used, these roots were immersed into cold clear acrylic , the teeth roots divided into four groups according to rotary system used for preparation of the canals (ten roots for each group):. group I: ProTaper Next rotary system, group II: IRaCe Plus rotar

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 17 2026
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparative Evaluation of the Centering Ability and Canal Transportation of Simulated S-Shaped Canals Instrumented with Different Nickel –Titanium Rotary Systems
...Show More Authors

Background: The purpose of this study was to evaluate and compare centering ability and canal transportation of simulated S-shaped canals instrumented with four different types of rotary nickel-titanium systems. Materials and Methods: Forty simulated S-shaped canals in resin blocks were divided into four groups of ten each and were instrumented to an apical size 25 by different instrumentation technique using ProTaper Universal files (group A), ProTaperNext (group B), Reciproc (group C) and WaveOne (group D).Centering ability and canal transportation was measured at (11) measuring points from D0 to D10 bysuperimposion of the pre- and post-operative images obtained by using digital camera in standardized manner. An assessment of the canals

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 01 2021
Journal Name
World Heart Journal
Change in Left Ventricular Size and Ejection Fraction in Patients at Rest vs. Stress with Different Degrees of Ischemic Heart Failure
...Show More Authors

Background and Aim. Coronary artery disease (CAD) is a major risk factor for the progression to heart failure (HF), which is associated with an increase in left ventricular volume (LVV). This study aims to measure ventricular function and myocardial perfusion imaging markers of the left side of the heart, which can be performed with injection of a 99mTc at stress and rest by using single-photonemission-computed-tomography (SPECT). Subject and methods. The study included 121 patients with CAD, comprising 53 females and 68 males with ages between 25 to 88 years and 265 healthy subjects comprising 84 males and 181 females. All patients and healthy subjects volunteered to participate in this study. They were classified according to

... Show More
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Estimation Of Left Ventricular Ejection Fraction Using Mitral Annular Displacement Derived By Speckle Tracking Echocardiography In Patients With Different Heart Diseases
...Show More Authors

Background: Speckle tracking echocardiography (STE)-derived mitral annular displacement (MAD) utilizes the speckle tracking technique to measure strain vectors, which provides accurate estimates of left ventricular ejection fraction (LVEF).Objectives: To validate the accuracy of mitral annular displacement (MAD), assessed by Speckle Tracking Echocardiography (STE), as a surrogate for determination of left ventricular systolic function in comparison to 2-Dimensions Simpson method in patients with different heart diseases.Methods : This cross-sectional study included patients who referred to outpatient department of Ibn Albitar Center for Cardiac Surgery, Baghdad, Iraq, between October 2012 and April 2013. STE continuously tracked annular

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Science
Structural, Optical, and Morphological Study of the Zinc Oxide Nano-Thin Films with Different Thickness Prepared by Pulsed Laser Deposition Technique
...Show More Authors

The goal of this investigation is to prepare zinc oxide (ZnO) nano-thin films by pulsed laser deposition (PLD) technique through Q-switching double frequency Nd:YAG laser (532 nm) wavelength, pulse frequency 6 Hz, and 300 mJ energy under vacuum conditions (10-3 torr) at room temperature. (ZnO) nano-thin films were deposited on glass substrates with different thickness of 300, 600 and 900 nm. ZnO films, were then annealed in air at a temperature of 500 °C for one hour. The results were compared with the researchers' previous theoretical study. The XRD analysis of ZnO nano-thin films indicated a hexagonal multi-crystalline wurtzite structure with preferential growth lines (100), (002), (101) for ZnO nano-thin films with different thi

... Show More
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Effect of Different Soil Organic Carbon Content in Different Soils on Water Holding Capacity and Soil Health
...Show More Authors
Abstract<p>An experiment was carried out to study the effect of soil organic carbon (SOC) and soil texture on the distance of the wetting front, cumulative water infiltration (I), infiltration rate (IR), saturated water conductivity (Ks), and water holding capacity (WHC). Three levels ( 0, 10, 20, and 30 g OC kg-1 ) from organic carbon (OC) were mixed with different soil materials sandy, loam, and clay texture soils. Field capacity (FC) and permanent wilting point (PWP) were estimated. Soil materials were placed in transparent plastic columns(12 cm soil column ), and water infiltration(I) was measured as a function of time, the distance of the wetting front and Ks. Results showed that advance we</p> ... Show More
View Publication
Scopus (8)
Crossref (8)
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Comparison of HF and HCl Chemical Laser Parameters by using Mathematical Model
...Show More Authors

A simplified theoretical comparison of the hydrogen chloride (HCl) and hydrogen fluoride (HF) chemical lasers is presented by using computer program. The program is able to predict quantitative variations of the laser characteristics as a function of rotational and vibrational quantum number. Lasing is assumed to occur in a Fabry-Perot cavity on vibration-rotation transitions between two vibrational levels of hypothetical diatomic molecule. This study include a comprehensive parametric analysis that indicates that the large rotational constant of HF laser in comparison with HCl laser makes it relatively easy to satisfy the partial inversion criterion. The results of this computer program proved their credibility when compared with th

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 17 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of ginger extract on Mutans streptococci in comparison to chlorhexidine gluconate
...Show More Authors

Background: The rhizome of ginger is used in cooking and for medicinal purposes such as anti-bacterial, anti-fungal, anti-inflammatory and antioxidant. The aims of the study were to test the effect of ethanolic extract of ginger on growth, adherence and acidogenicity of mutans streptococci in comparison to chlorhexidine gluconate 0.2% and de-ionized water. Materials and methods: From saliva often volunteers (dental students 20-22 years); mutans streptococci was isolated, purified and diagnosed according to morphological characteristic and biochemical tests. Ginger was powdered and extracted, different concentrations of ginger extract were prepared. Chlorhexidine gluconate 0.2% used as a control positive; while de-ionized water was used as a

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of Some Semi-parametric Methods in Partial Linear Single-Index Model
...Show More Authors

The research dealt with a comparative study between some semi-parametric estimation methods to the Partial linear Single Index Model using simulation. There are two approaches to model estimation two-stage procedure and MADE to estimate this model. Simulations were used to study the finite sample performance of estimating methods based on different Single Index models, error variances, and different sample sizes , and the mean average squared errors were used as a comparison criterion between the methods were used. The results showed a preference for the two-stage procedure depending on all the cases that were used

View Publication Preview PDF
Crossref
Publication Date
Mon May 20 2019
Journal Name
The Journal Of Engineering
Experimental comparison of two linear machines developed for the free piston engine
...Show More Authors

: In this study, a linear synchronous machine is compared with a linear transverse flux machine. Both machines have been designed and built with the intention of being used as the power take off in a free piston engine. As both topologies are cylindrical, it is not possible to construct either using just flat laminations and so alternative methods are described and demonstrated. Despite the difference in topology and specification, the machines are compared on a common base in terms of rated force and suitability for use as a generator. Experience gained during the manufacture of two prototypes is described.

View Publication Preview PDF
Crossref (10)
Clarivate Crossref