Background/: Buccal tubes are orthodontic attachments used on the posterior teeth instead of bands, so it is important to focus on the effect of their properties on orthodontic treatment. The aims of the present in vitro study are to evaluate and compare the buccal tube front and back openings dimensions and the torsional play angle of six different brands. Materials and Methods: The samples consisted of Single bondable, non-convertible first molar buccal tubes from six brands supplied from six companies (Dentaurum, Forestadent, Ormco, 3M, American Orthodontic, A-Star). Regarding tube opening dimension, ten buccal tubes of each brand were examined by an optical microscope. Each tube was fixed during examination using synthetic mud and oriented for observation of the front and back slot openings. A picture was taken for both tube openings and the result appeared on the computer's screen where width and height measurements were made. While regarding torsional play angle, ten buccal tubes of each brand were used. Each tube was fixed on a metal block attached to a surveyor base. Then an L-shaped wire was inserted inside the front opening of the tube. Two photographs were taken, one with the wire in free fall position and the other with the wire elevated by a 10g weight with the same angle of shooting as the first photograph. Later, the two images were superimposed in Adobe Photoshop program, and an electronic MB-ruler Software was used to calculate the angle which represents the torsional play within each tube. The data were then statistically analyzed using ANOVA and LSD tests. Results: There are marked differences between measured tube dimensions and the manufacturer stated dimensions with the front tube openings being generally larger than the back opening dimensions. Furthermore, the torsional play angle was highest in A-Star and smallest in Ormco's tubes. This angle was significantly correlated to the height of the tube front opening. Conclusion: It can be concluded that tube dimension varies among different companies and effect greatly torsional play angle.
Abstract
Theoretically, the aim of the paper is identify linguistic expressions, such as proverbs, wise sayings, and popular sayings, used by the playwright A. N. Ostrovsky , along with their translations into Arabic by the Iraqi translator Abdullah Habbah and the Syrian translator HashimHumadi. And practically, there were found about fifty sayings, made of proverbs, wise sayings and popular sayings, which were identified and taken into analysis in respect to their Arabic translation , with the specification of the best rendition of the original text.
Critics and professionals em
... Show MoreThe research is exposed to the concept of rough discourse in contemporary theater with a critical reading that takes the genealogical work as a starting point in deconstructing the references of rough discourse and pursuing its paths in the civilization and cultural framework and how it identifies aesthetically within the theatrical field and the extents of its procedural treatments in order to reveal it and clarify its limits and representations, as the research included the first chapter. (methodological framework), the second chapter (theoretical framework), which included two sections, the first took place under the title (rough dramatization), while the second topic took place under the title (rough drama), and the second chapter re
... Show MorePositive and negative parity states for 114Te have been studied applying the vibration al limit U(5) of Interacting boson model (IBM- 1 ) . The present results have shown their good agreement with experimental data in addition to the determination of the spin/parity of new energy levels are not assigned experimentally as the levels 0+2 and 5+1 and the levels 3"1 and 5-1 . Then back propagation multiLayer neural network used for positive and negative parity states for 114Te and shown their membership to the Vibration limit U(5) the network implemented by MATLAB system.
The effect of using different R -molar ratio under variable reaction conditions (acidic as well as basic environment and reaction temperature) have been studied. The overall experiments are driven with open and closed systems. The study shows that there is an optimum value for a minimum gelling time at R equal 2. The gelling time for all studied open system found to be shorter than in closed system. In acidic environment and when R value increased from 2 to 10, the gelling time of closed systems has increased four times than open systems at T=30 ?C and fourteen times when temperature reaction increased to 60 ?C. While in basic environment the influence of increasing R value was limited.
Background: Orthodontic mini-implants are increasingly used in orthodontics and the bone density is a very important factor in stabilization and success of mini-implant. The aim of this study was to observe the relationship among maximum bite force (MBF); body mass index (BMI); face width, height and type; and bone density in an attempt to predict bone density from these variables to eliminate the need for CT scan which have a highly hazard on patient. Materials and Methods: Computed tomographic (CT) images were obtained for 70 patients (24 males and 46 females) with age range 18-30 years. The maxillary and mandibular buccal cortical and cancellous bone densities were measured between 2nd premolar and 1st molar at two levels from the alveol
... Show MoreThe study aims at measuring the dimensions of binding and non-binding social responsibility and its relation to the organizational performance in telecommunication companies in the Republic of Yemen using analytical descriptive approach and questionnaire as a main tool for data collection and comprehensive inventory method.
It has been found that there is a positive effect and significant moral relation between social responsibility with its binding and non-binding dimensions and the organizational performance of telecommunication companies in the Republic of Yemen at a level of significance below (0.05). It has also been found that the correlation between the non-binding social responsibilit
... Show MoreTwisted tape insertion in smooth plain tube is one of types of passive methods that is used to enhance heat transfer. Swirl fluid flow inside tube and related heat transfer characteristics are very complex. ANSYS FLUENT (V 16.1) and ASPEN industrial program are used in analyzing this technique for enhancement heat transfer. A circular plain tube has length L=8534mm and 17 mm inner diameter with twisted tape has twist ratio of y = (H/D) = (150/17) =8.8 along with a plain tube were considered for this study. Eight Reynolds numbers (Re) of 784, 1000, 2000, 3000, 4000, 5000, 6000 and 7000 are used to analyze the response of thermal performance. Crude oil API 28 exit temperature, film heat transfer coefficient, Nusselt number
... Show MoreTwisted tape insertion in the smooth plain tube is one of the types of passive methods that are used to enhance heat transfer. Swirl fluid flow inside the tube and related heat transfer characteristics are very complex. ANSYS FLUENT (V 16.1) and ASPEN industrial program are used in analyzing this technique for enhancement heat transfer. A circular plain tube has length L=8534mm and 17 mm inner diameter with a twisted tape of twist ratio of y = (H/D) = (150/17) =8.8 along the plain tube were considered for this study. Eight Reynolds numbers (Re) of 784, 1000, 2000, 3000, 4000, 5000, 6000 and 7000 are used to analyze the response of thermal performance. Crude oil API 28 exit temperature, film heat transfer coefficient, Nus
... Show MoreAbstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,
... Show More