Background/: Buccal tubes are orthodontic attachments used on the posterior teeth instead of bands, so it is important to focus on the effect of their properties on orthodontic treatment. The aims of the present in vitro study are to evaluate and compare the buccal tube front and back openings dimensions and the torsional play angle of six different brands. Materials and Methods: The samples consisted of Single bondable, non-convertible first molar buccal tubes from six brands supplied from six companies (Dentaurum, Forestadent, Ormco, 3M, American Orthodontic, A-Star). Regarding tube opening dimension, ten buccal tubes of each brand were examined by an optical microscope. Each tube was fixed during examination using synthetic mud and oriented for observation of the front and back slot openings. A picture was taken for both tube openings and the result appeared on the computer's screen where width and height measurements were made. While regarding torsional play angle, ten buccal tubes of each brand were used. Each tube was fixed on a metal block attached to a surveyor base. Then an L-shaped wire was inserted inside the front opening of the tube. Two photographs were taken, one with the wire in free fall position and the other with the wire elevated by a 10g weight with the same angle of shooting as the first photograph. Later, the two images were superimposed in Adobe Photoshop program, and an electronic MB-ruler Software was used to calculate the angle which represents the torsional play within each tube. The data were then statistically analyzed using ANOVA and LSD tests. Results: There are marked differences between measured tube dimensions and the manufacturer stated dimensions with the front tube openings being generally larger than the back opening dimensions. Furthermore, the torsional play angle was highest in A-Star and smallest in Ormco's tubes. This angle was significantly correlated to the height of the tube front opening. Conclusion: It can be concluded that tube dimension varies among different companies and effect greatly torsional play angle.
This study aimed to investigate the influence of longitudinal steel embedded tubes located at the center of the column cross-section on the behavior of reinforced concrete (RC) columns. The experimental program consisted of 8 testing pin-ended square sectional columns of 150×150 mm, having a total height of 1400 mm, subjected to eccentric load. The considered variables were the steel square tube sizes of 25, 51 and 68 mm side dimensions and the load eccentricity (50 and 150) mm. RC columns were concealed steel tubes with hollow ratios of 3%, 12% and 20% depending on tube sizes used. The experimental results indicated an improvement in the overall behavior of eccentric columns when steel embedded tubes are used. The maximum gain in
... Show MoreThe study aimed to identify the relationship between the speed and direction of the ball's rotation in the accuracy of the front and rear side longitudinal blow in wheelchair tennis players. The descriptive approach wasused in the manner of correlations to suit the nature of the problem to be studied. The research community identified the 32 players aged18 and over, and the search sample was selected from players with a local classification registered with the 2020 Wheelchair Ground Tennis Federation (2020) in the intentional manner of 8 players, using Smart Tennis Sensor technology to measure the speed and direction of the ball and test the accuracy of the front and rear side longitudinalstraightstrike. She conducted the reconnaissance exp
... Show MoreMost studies on deep beams have been made with reinforced concrete deep beams, only a few studies investigate the response of prestressed deep beams, while, to the best of our knowledge, there is not a study that investigates the response of full scale (T-section) prestressed deep beams with large web openings. An experimental and numerical study was conducted in order to investigate the shear strength of ordinary reinforced and partially prestressed full scale (T-section) deep beams that contain large web openings in order to investigate the prestressing existence effects on the deep beam responses and to better understand the effects of prestressing locations and opening depth to beam depth ratio on the deep beam performance and b
... Show MoreDeep beams are used in wide construction fields such as water tanks, foundations, and girders in multi-story buildings to provide certain areas free of columns. In practice it is quite often occurring to create web opening in deep beams to supply convenient passage of ventilation ducts, cable channels, gas and water pipes. Experimental studies of ten 10 deep beams were carried out, where two of them are control specimens without openings and eight with large web openings in the shear spans. The variables that have been adopted are the ratio of the shear span to the overall depth of the member cross-section, location and dimensions of the opening. Test results showed that there was a decrease in the load carrying capacity of deep bea
... Show MoreDeep beams are used in wide construction fields such as water tanks, foundations, and girders in multi-story buildings to provide certain areas free of columns. In practice it is quite often occurring to create web opening in deep beams to supply convenient passage of ventilation ducts, cable channels, gas and water pipes. Experimental studies of ten 10 deep beams were carried out, where two of them are control specimens without openings and eight with large web openings in the shear spans. The variables that have been adopted are the ratio of the shear span to the overall depth of the member cross-section, location and dimensions of the opening. Test results showed that there was a decrease in the load carrying capacity of deep bea
... Show MoreIt is commonly known that Euler-Bernoulli’s thin beam theorem is not applicable whenever a nonlinear distribution of strain/stress occurs, such as in deep beams, or the stress distribution is discontinuous. In order to design the members experiencing such distorted stress regions, the Strut-and-Tie Model (STM) could be utilized. In this paper, experimental investigation of STM technique for three identical small-scale deep beams was conducted. The beams were simply supported and loaded statically with a concentrated load at the mid span of the beams. These deep beams had two symmetrical openings near the application point of loading. Both the deep beam, where the stress distribution cannot be assumed linear, and the ex
... Show MoreObjective: The present study was aimed to develop a pH-triggered in situ gel for local release of lidocaine hydrochloride (lidocaine HCL) in the buccal cavity to improve the anesthetic effect of this amino amide drug which has very high water solubility. The formulations were introduced to the oral cavity as a spray to improve compliance and for easier administration.Methods: In this work, two grades of carbopol (934 and 940)-based in situ gel spray were designed. The formulations containing lidocaine HCl 5% were prepared by mixing different concentrations of carbopol with xanthan gum. Eight formulations were investigated and evaluated for gelation capacity, spray angle, volume of solution delivered per each actuation, rheological p
... Show MoreBackground: urethrocutaneous fistula after hypospadias surgery repair is the most common complication and remains a frustrating problem for surgeon and the patient. The problem is exacerbated because the urethrocutaneous fistula may recur which adds more demands surgery. Objectives: The purpose of this study is to evaluate of the use of oral mucosal graft for management of recurrent urethrocutaneous fistula after hypospadias repair. Patients and Methods: twelfth patients with age ranging from 4 year to 15 years were presented with history of recurrent fistula. Most of fistula were located in proximal penile and penoscrotal region (58.3%) . those patients were repaired by using oral mucosal graft with mean postoperative follow up period up t
... Show More
Harold Pinter often portrays the dilemma of obliterated figures that are incapable of feeling of their own existences. These figures feel exhausted and frustrated in a world that deprives them their humanity. They retreat into a limited world where they look for security and protection. The characters' feeling of security is threatened by outside forces represented by intruding persons who stand for the mysterious powers that are indefinable. The conflict between these intruders and the characters finally ends with the characters’ defeat. The reason for the intruders' attack on the victims remains ambiguous and is not explained. The element of mystery pervades Pinter's plays and represents one of
... Show MoreThis study aimed to evaluate the effectiveness of a novel concrete-encased column (CE) using small circular steel tubes filled with cementitious grouting material (GFST) as the primary reinforcement instead of traditional steel bars. The research involved three different types of reinforcement: conventional steel bars, concrete-filled steel tubes with 30% of the reinforcement ratio of steel bars, and concrete-filled steel tubes with the same reinforcement ratio as steel bars. Twenty-four circular concrete columns were tested and categorized into six groups based on the type of reinforcement employed. Each group comprised four columns, with one subjected to concentric axial load, two subjected to eccentric axial load (with eccentrici
... Show More