Back ground: Microbial penetration inside the implant's internal hole creates a bacterial reservoir that is related with an area of inflamed connective tissue opposite the fixture-abutment junction and this can affect the health of the peri-implant tissue. Aims of the study: Evaluate the types aerobic and anaerobic bacterial count-percentage and difference between Aerobic and Anaerobic microflora in the implant screw hole three months after implant placement. Monitor the periodontal health status of all patients, throughout the study. Material and methods: Study methodology; Eight partially edentulous patients received 20 dental implants and these implants done with flapless surgical procedure. All patients examined clinically to determined their oral health status by examination of their plaque index, Gingival index and Bleeding on probing, each two weeks for 90 days (8visits) throughout the study period. Three months after that, the plaque sample collected from the internal hole of fixture and transfer to bacterial investigation and assessment the amount of anaerobic and aerobic bacteria. Results: Although the anaerobic viable count is higher than that of aerobic, but with statistically not significant difference between those counts (P>0.05). Keywords: screw hole, flapless surgical implant placement, bacterial count, Aerobic and Anaerobic bacteria
Abstract
All the economic units whether productive or service units , strive to achieve specific objectives , their presence and continuity depend on them and the quality of the performance and service present to the society . This units to be able to achieve their objectives , must own basic assets to perform the activities , and apply laws , systems , and instructions , in addition to legal , managerial , and financial authorities . So this units to endeavor maintain this assets , in addition to sound application of laws ,systems . and procedures to enhance their performance . For this purpose arise the role of internal control and internal check in maintenance of assets and sound application of&n
... Show MoreMany drilling problems (lost circulation, hurdle in running casing, poor cement jobs, high torque and drag and the necessity of re-drilling and, mechanical stuck caused by cutting accumulation in the wellbore) can be avoided by good hole cleaning during drilling operation especially in directional wells.
In this experimental work, the cutting transport ratio (CTR) in hole inclined (60 degree) from vertical was estimated by using three values of drilling mud viscosities, three annular velocities, two types of cuttings size and two rotation speed of inner pipe (RPM). Note that the rig consisted from PVC outer casing 4 1/2 inch as OD diameter and inner dri
Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M
... Show MoreIn this work, electrochemical process was presented to polymerized eugenol on Gr.2 and Gr.5 titanium alloys before and after treated by Micro Arc Oxidation (MAO), where Gr.2 is commercial pure titanium and Gr.5 is Ti-6Al-4V dental alloys. The deposited layers were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adhesion strength of polymeric thin-film was estimation by using pull-off adhesion test and the result was the adhesion strength of PE was (1.23 MPa) on Gr.2 before MAO and increase to (1.98 MPa) on Gr.2 after MAO treatment. The corrosion behavior of Gr.2 and Gr.5 alloy in artificial saliva environment at
... Show MoreThe aim of this study was to evaluate the effects of local application of bisphosphonate gel and recombinant human bone morphogenic protein 2 gel, on titanium dental implant stability and marginal bone level. Twenty-seven patients with upper and lower missing posterior tooth/teeth were included in the study with a total of 71 implants that were used for rehabilitation. The implants were randomly divided into 4 groups: 3 study groups and 1 control. Group1; local application of bisphosphonate gel, group 2; local application of recombinant human bone morphogenic protein 2 gel, group 3; local application of a mixed formula of both gels. The gel application was immediately preimplant insertion, group 4; implant insertion without application of a
... Show MoreBackground: Corticotomy-assisted orthodontic treatment is done to induce a state of increased tissue turnover and transient osteopenia, which is followed by a faster rate of orthodontic tooth movement. It considered as an adjunct treatment option for orthodontic treatment of adults. The aim of this Study was to elucidate the effectiveness of a new surgical approach for acceleration of maxillary canine retraction in human with laser assisted flapless corticotomy and evaluate its effect on vitality of pulp and gingival sulcus depth. Materials and methods: the sample comprised of 15 Iraqi patients (9 females and 6 males; mean age 21.7), who were required extraction for their maxillary first premolars followed by retraction of the canines as pa
... Show Morethe electron correlation effect for inter-shell can be described by evaluating the fermi hole and partial fermi hole for Li atom comparing with Be+ and B+2 ions