Preferred Language
Articles
/
jbcd-245
The frontal sinus dimensions in mouth and nasal breathers in Iraqi adult subjects
...Show More Authors

Background: The frontal sinus area can be used as a diagnostic aid to recognize mouth breather subjects. The aims of this study were to determine the gender difference in each group, to compare the frontal sinus area between mouth breather and nasal breather group, and to verify the presence of correlation between the frontal sinus area and the cephalometric skeletal measurements used in this study. Materials and Methods: Cephalometric radiographs were taken for 60 adults (30 mouth breathers and 30 nasal breathers) age range (18-25), for each group 15 males and 15 females, in the orthodontic clinic in the college of Dentistry at Baghdad University. The control group (nasal breather) with skeletal class I and ANB angle ranged between 2-4º, and have clinically class I occlusion. The cephalometric measurement for each group were taken, the cephalometric radiographs were analyzed by using AutoCAD 2007 program. Results and Conclusions: In comparison to nasal breather the mouth breather has larger Gonial angle giving a tendency to posterior rotation with growth of the mandible. The mouth breather has less maxillary length than the nasal breather. No effect of gender in mouth breather on gonial, SNA and SNB angles, no effect of gender in nasal breather on gonial angle, while the other cephalometric measurements were higher in males than females in each group. The mouth breather showed more anteroposterior extent of anterior cranial base; also the mouth breather show an increase in all facial height than the nasal breathers, the frontal sinus area is smaller in mouth breather than in nasal breather. The frontal sinus area showed correlation for both groups (Mouth and nasal breather) with maxillary Length, mandibular length, ramal length, S-N length, TAFH, UAFH, LAFH, TPFH, LPFH, and UPFH. There is only correlation of frontal sinus with the SNA and SNB angles in nasal breather and no significant correlation for both groups with the gonial angle.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Metal Complexes of Multidentate N<sub>2</sub>S<sub>2</sub> Heterocyclic Schiff-base Ligands;Formation, Structural Characterisation and Biological Activity
...Show More Authors
Abstract<p>The synthesis of ligands with N<sub>2</sub>S<sub>2</sub> donor sets that include imine, an amide, thioether, thiolate moieties and their metal complexes were achieved. The new Schiff-base ligands; N-(2-((2,4-diphenyl-3-azabicyclo[3.3.1]nonan-9-ylidene)amino)ethyl)-2-((2-mercaptoethyl)thio)-acetamide (H<sub>2</sub>L<sup>1</sup>) and N-(2-((2,4-di-p-tolyl-3-azabicyclo[3.3.1]nonan-9-ylidene)amino)ethyl)-2-((2-mercaptoethyl)thio) acetamide (H2L<sup>2</sup>) were obtained from the reaction of amine precursors with 1,4-dithian-2-one in the presence of triethylamine as a base in the CHCl3 medium. Complexes of the general formula K<sub>2<</sub></p> ... Show More
View Publication
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Wed May 10 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Synthesis, Characterization and Analytical Study of Metal Complexes Derived from 1,2-Bis-(4´-Amino-2´,3´- Dimethyl-1´- Phenyl-Pyrazolinyl)- Diimino Ethane
...Show More Authors

       Six transition metal complexes of Cr (III), Mn(II), Co(II), Ni(II), Cu(II), and Zn(II) were prepared using 1,2-bis -(4-Amino-2,3-dimethyl-1- phenyl-pyrazolinyl)-diimino ethane(L) as ligand.  These complexes were characterized by elemental analysis, magnetic susceptibility, UV/VIS and FT-IR spectroscopy. These data showed that the solid complexes of Mn(II), Co(II), Zn(II) were tetrahedral geometry, and Cr(III) was octahedral while the symmetry around  Ni(II) and Cu(II) ions with the new ligand were square planar of the formula [ML]Cl2 ,  M=Ni(II) and Cu(II).        

      A simple method for the determina

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 23 2024
Journal Name
European Journal Of Orthodontics
Poly-Ether-Ether-Ketone versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 2: periodontal health and microbial biofilm assessment
...Show More Authors
Abstract<sec> <title>Background

Retainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.

Objectives

To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).

Trial design

A two-arm parallel groups single-centre randomized c

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Mon Sep 18 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Light Induced Hydrogen Production From Ethanolic Aqueous Solutions Sensitizzed By 2,4-Dimetboxy Benzylidene-2- Hydroxy Aniline And Some of Its Metal Complexes
...Show More Authors

Hydrogen   productions  were  achieved    by  irradiating  ethanol ic aqueous solutions (20%. v/v) containing  mixtures of  the  ligand  2,4- dimethoxybcnzylidene-2-hydroxy    aniline     (HL)     or    one    of     i ts complexes  (ML2)   wi th  the  following  divalent  ions:  fVbl  (II),  Fc(IT), Co(II). Ni( rt ), Cu(H) and  Zn (11), as photosensi1izers, methyl  viol ogen (MY.:-)    as   electron   acceptor.  ethylene    diamine &nbsp

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Nanomaterials
Comparative Studies on Thermal Performance of Conic Cut Twist Tape Inserts with SiO<sub>2</sub>and TiO<sub>2</sub>Nanofluids
...Show More Authors

This paper presents a comparison study on thermal performance conic cut twist tape inserts in laminar flow of nanofluids through a constant heat fluxed tube. Three tape configurations, namely, quadrant cut twisted tape (QCT), parabolic half cut twisted tape (PCT), and triangular cut twisted (VCT) of twist ratioy= 2.93 and cut depthde= 0.5 cm were used with 1% and 2% volume concentration of SiO2/water and TiO

... Show More
View Publication
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Jun 08 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of addition ZrO2-Al2O3 nanoparticles mixture on some properties and denture base adaptation of heat cured acrylic resin denture base material
...Show More Authors

Background: The PMMA polymer denture base materials are low mechanical properties, adaptation of the denture base to underlying tissue is important for retention and stability of denture. The aim of the study was toevaluate the effect of mixtureZrO2-Al2O3 nanoparticles on impact strength, transverse strength, hardness, roughness, denture base adaptation of heat cured acrylic resin denture base material. Materials and methods: One hundred (100) specimens were prepared, the specimens were divided into five groups (20 specimens to each) according to the test type, each group was subdivided in to two subgroups (control and experimental) each subgroup consist of 10 specimens, the experimental group included mixture of 2% (ZrO2-Al2O3ratio2:1) b

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2022
Journal Name
Baghdad Science Journal
Preparation-and Spectroscopic Characterization of Transition Metal Complexes with Schiff base 2-[1-(1H-indol-3-yl)ethylimino) methyl]naphthalene-1-ol
...Show More Authors

The ligand 2-[1-(1H-indol-3-yl)ethylimino) methyl]naphthalene-1-ol, derived from 1-hydroxy-2-naphthaldehyde and 2-(1H-indol-3-yl)ethylamine, was used to produce a new sequence of metal ions complexes. Thus ligand reactions with NiCl2.6H2O, PdCl2, FeCl3.6H2O and H2PtCl6.6H2O were sequentially made to collect mono-nuclear Ni(II), Pd(II), Fe (III), and Pt(IV). (IR or FTIR), Ultraviolet Reflective (UV–visible), Mass Spectra analysis, Bohr-magnetic (B.M.), metal content, chloride content and molar conductivity have been the defining features of the composites. The Fe(III) and Pt(IV) complexes have octahedral geometries, while the Ni(II) complex has tetra

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Aug 08 2024
Journal Name
Journal Of Inorganic And Organometallic Polymers And Materials
Schiff-Base System of Glutaraldehyde Crosslinked Chitosan-Algae-Montmorillonite Clay K10 Biocomposite: Adsorption Mechanism and Optimized Removal for Methyl Violet 2B Dye
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Lab-On-a-Chip an integrated microfluidic device sensitive low-Cost, and Rapid with a syringe pump for Analysis of Ibuprofen
...Show More Authors

Abstract: Microfluidic devices present unique advantages for the development of efficient drug assay and screening. The microfluidic platforms might offer a more rapid and cost-effective alternative. Fluids are confined in devices that have a significant dimension on the micrometer scale. Due to this extreme confinement, the volumes used for drug assays are tiny (milliliters to femtoliters).

 In this research, a microfluidic chip consists of micro-channels carved on substrate materials built by using Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters have influence on the width, depth, roughness of the chip. In order to have regular

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 08 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different palatal vault shapes and woven glass fiber reinforcement on dimensional stability of high impact acrylic denture base [Part I]
...Show More Authors

Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture.This study evaluated tostudy the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on adaptation or gap space between the denture base and the stone cast and compare with non-fiber reinforcement and effect of palatal vault shapes on adaptation of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymeri

... Show More
View Publication Preview PDF