Preferred Language
Articles
/
jbcd-243
The effect of different oral hygiene regimens on the quantity of cariogenic plaque on orthodontic bands with different attachments (A clinical photographic study)
...Show More Authors

Background: Fixed orthodontic appliances impede the maintenance of oral hygiene and result in plaque accumulation leads to enamel demineralization caused by acids produced by bacteria. Studies on plaque control strategies in orthodontic populations are limited. This might be caused by difficulties in the quantitative evaluation of dental plaque because the teeth have various levels of bracket coverage, and different tooth sizes and malocclusions, making the traditional categorical indices complex. The present study aims to evaluate the effect of different hygiene protocols on plaque quantity on bands with different attachments. Materials and method: Twenty patients had four bands within the orthodontic appliance. Then randomly divided into four groups of hygiene regimens where group A used chlorhexidine dentifrice, group B used fluoridated dentifrice, group C used chlorhexidine mouthwash along with chlorhexidine dentifrice and group D used chlorhexidine mouthwash in addition to the fluoride dentifrice. Bands were removed four weeks after the appliance been in place, cut out carefully into 2 pieces from the center of the mesial and distal contact areas, biochemical test (clinprocario L-pop) was applied then 80 digital photographs were obtained. Four areas of interest were estimated which are mesially and distally to each attachment (2 mm) in width each. Percentage of plaque in these areas was calculated and statistically analyzed. Results: Side difference revealed that the plaque accumulated on the right sided bands more than the left, however the difference was not significant. It was also found that the lower bands had insignificantly higher amount of plaque than the upper ones. Conclusions: The four groups of oral hygiene regimens have no significant different effects on the plaque amount. Moreover, the oral hygiene maintenance is more difficult in the right side than the left side but the difference was not significant. The lower arch accumulated insignificantly more plaque than the upper. Also, difference in attachments has no influence on plaque amount.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Apr 29 2022
Journal Name
International Journal Of Dentistry
The Effects of Zinc-Containing Mouthwashes on the Force Degradation of Orthodontic Elastomeric Chains: An In Vitro Study
...Show More Authors

Objective. This study aimed to evaluate and compare the force degradation of two types of elastomeric chains following different periods of immersion in zinc-containing mouthwashes. Materials and Methods. Four hundred and forty pieces of Elasto-Force and Super Elasto-Force elastomeric chains were divided into two control and eight experimental groups. The pieces were stretched to 25 mm on pins mounted on an acrylic block and stored in distilled water at 37°C. The experimental groups were immersed in four different types of mouthwash for one minute twice a day throughout the test period. Ten continuous thermocycles per day between cold and hot water baths (5–55°C) were carried out. Forces were measured at six-time intervals (in

... Show More
View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Clinical Dentistry Preview Publication Details
The effect of surgical approaches on the stability and marginal bone loss of early loaded slactive implants with screw retention mean: Comparative clinical and radiological prospective study
...Show More Authors

Purpose: This study aimed to compare the stability and marginal bone loss of implants inserted with flapped and flapless approaches 8 weeks after surgery and 3 months after loading. Material and Methods: Thirty SLActive implants were inserted in 11 patients and early loaded with final restoration 8 weeks after healing period. The stability values determined by Osstell and the marginal bone loss measured by CBCT at the initial time (1st) and 8 weeks of the healing period (2nd) and 3 months after loading (3rd). Results: The overall survival rate was 100%. A significant increase in the 3rd implant stability value in the age of ˂ 40. A significant decrease in the 2nd implant stability value in both gender and traumatic zone with a flapless app

... Show More
View Publication Preview PDF
Scopus
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
The Reliability of Two Different Laser Wavelengths in Inducing Bone Healing Around Dental Implants: Comparative Clinical Trial
...Show More Authors

Background/purpose: Dental implantology involves different treatments that have been used in conjunction with dental implant surgery to increase implant stability and bone regeneration process. Photobiomodulation( PBM) can be one of these techniques. The objective of this study was to evaluate the bone density around implants. Materials and methods: in this study, 10 individuals had 20 implants inserted in the posterior of their mandibles. each patient received two implants the left side served as the control whereas the right side served as the study group with a diode laser (same patients). measurements were made for each implant. Measurements were obtained using cone-

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 26 2018
Journal Name
Al-khwarizmi Engineering Journal
Study the Effect of Different Percentages of Natural (Orange Peels and Date Seeds) and Industrial Materials (Carbon and Silica) on the Mechanical and Thermal Properties of Polymeric Reinforced Composites
...Show More Authors

Mechanical and thermal properties of composites, consisted of unsaturated polyester resin, reinforced by different kinds of natural materials (Orange peels and Date seeds) and industrial materials (carbon and silica) with particle size 98 µm were studied. Various weight ratios, 5, 10, and 15 wt. % of natural and industrial materials have been infused into polyester. Tensile, three-point bending and thermal conductivity tests were conducted for the unfilled polyester, natural and industrial composite to identify the weight ratio effect on the properties of materials. The results indicated that when the weight ratio for polyester with date seeds increased from 10% to 15%, the maximum Young’s modulus decreased by 54%. When the weight rat

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Aug 21 2021
Journal Name
Engineering, Technology & Applied Science Research
The Response of a Highly Skewed Steel I-Girder Bridge with Different Cross-Frame Connections
...Show More Authors

Braces in straight bridge systems improve the lateral-torsional buckling resistance of the girders by reducing the unbraced length, while in horizontally curved and skew bridges, the braces are primary structural elements for controlling deformations by engaging adjacent girders to act as a system to resist the potentially large forces and torques caused by the curved or skewed geometry of the bridge. The cross-frames are usually designed as torsional braces, which increase the overall strength and stiffness of the individual girders by creating a girder system that translates and rotates as a unit along the bracing lines. However, when they transmit the truck’s live load forces, they can produce fatigue cracks at their connection

... Show More
View Publication
Crossref (5)
Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of 2 different techniques in second stage implant surgery
...Show More Authors

Background: Dental implant is one of the most important options for teeth replacement. In two stage implant surgery, a few options could be used for uncovering implants, scalpel and laser are both considered as effective methods for this purpose. The Aim of the study: To compare soft tissue laser and scalpel for exposing implant in 2nd stage surgery in terms of the need for anesthesia, duration of procedure and pain level assessment at day 1 and day 7 post operatively using visual analogue scale . Materials and methods: Ten patients who received bilateral implants participated after healing period completed, gingival depth over each implant was recorded and then implant(s) were exposed by either scalpel or laser with determination for th

... Show More
View Publication
Scopus (2)
Crossref (4)
Scopus Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
Different garlic forms: (lobster, mashed, crushed) and their effect on quality qualities And the molecular life of the fermented cucumber and flavor
...Show More Authors

This study aimed to isolate and identifye the growth of microorganisms and
their effect on pickled cucumber and cabbage, the study also investigated the effect of
garlic (in the form of segments, chopped or crushed) on the mentioned pickled –food
features . Furthermore, a sense based comparison is made between vinegar-preserved
samples and vinegar-garlic preserved ones.
The following results have been obtained:
1- The isolation of staph. aureus alone from the samples and the study of its physical
and biochemical features.
2- The fresh garlic (segments, chopped and crushed) with concentration of 5%, 7.5%,
and 10% showed a damaging percentage of 100% to bacterial growth of staph. Aureus
after 24 hours of inc

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 06 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Time-related salivary cathepsin B levels and periodontal status in different orthodontic force magnitudes
...Show More Authors

Background: Biologically active substances, such as Cathepsin B (CAB) which is a lysosomalcystein protease may be involved in periodontal metabolism in the degradation of organic bone matrix containing collagen fibers in response to mechanical stress from orthodontic appliance. The aims of study were to determine and compare salivary levels of CAB, pH as well as clinical periodontal parameters (Plaque index PLI and gingival index GI) with different orthodontic force magnitudes at different time intervals. Materials and methods: A twenty-four patients (both gender) with age range (17-23) years had Angle's Class II division 1 malocclusion with GI >0.5 enrolled in this study. The level of salivary CAB and pH, in addition to the clinical period

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 24 2021
Journal Name
Applied Sciences
The Impact of Calcitriol on Orthodontic Tooth Movement: A Cumulative Systematic Review and Meta-Analysis
...Show More Authors

A cumulative review with a systematic approach aimed to provide a comparison of studies’ investigating the possible impact of the active form of vitamin D3, calcitriol (CTL), on the tooth movement caused by orthodontic forces (OTM) by evaluating the quality of evidence, based on collating current data from animal model studies, in vivo cell culture studies, and human clinical trials. Methods: A strict systematic review protocol was applied following the application of the International Prospective Register of Systematic Reviews (PROSPERO). A structured search strategy, including main keywords, was defined during detailed search with the application of electronic database systems: Medline/Pubmed, EMBASE, Scopus, Web of Science, and

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Journal Of Engineering
Numerical Study for HAWT Wake shape with different Angles of Attack
...Show More Authors

Increasing world demand for renewable energy resources as wind energy was one of the goals behind research optimization of energy production from wind farms. Wake is one of the important phenomena in this field. This paper focuses on understanding the effect of angle of attack (α) on wake characteristics behind single horizontal axis wind turbines (HAWT). This was done by design three rotors different from each other in value of α used in the rotor design process. Values of α were (4.8˚,9.5˚,19˚). The numerical simulations were conducted using Ansys Workbench 19- Fluent code; the used turbulence model was (k-ω SST). The results showed that best value for extracted wind energy was at α=19˚, spread distance of wak

... Show More
View Publication Preview PDF
Crossref