Background: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown restoration with deep chamfer finishing line all around the tooth with (1mm) depth, axial length (4mm) and convergence angle (6 degree). The specimens separated into two groups; Group A; eight specimens were scanned digitally by using Omnicam scanner; Group B; conventional impressions were taken for the remaining thirty two specimens and further subdivided to four groups according to the time of impression pouring; Group B1: PVS were poured after 30 minutes; Group B2: PVS were poured after 24 hours; Group B3: PVS were poured after 7 days; Group B4:PVS were poured after 14 days. Marginal discrepancy was measured at four points at each tooth surface. Sixteen points per tooth were measured using digital microscope at (180X) magnification. One-way ANOVA test and LSD test were carried out to see if there was any significant difference among the means of the conventional impression groups. Independent samples t-test was carried out to examine if there is any significant difference between digital and conventional impression technique. Results: group B2 had the least mean of marginal gap with statistically significant difference when compared to group B1 and statistically highly significant difference when compared to group B3 and B4. There was a statistically highly significant difference in the vertical marginal gap between digital impression technique and conventional impression. Conclusions: the pouring of conventional impression after 24 hours provides better marginal fit than other pouring time. The digital impression provides better marginal fit than conventional impression.
The primary objective of this study was to identify the obstacles and problems encountered in the work of sports clubs according to the reality of the application of administrative automation. The present study was conducted in the sports club headquarters of Baghdad within the timeframe of October 2021 to December 2021. In the present study, a descriptive approach was used by the researchers in an analytical style according to the nature of the problem to be studied. The research community of the current study was composed of 100 sports clubs in the governorate of Baghdad. A total of 80 questionnaires were filled by the sample participants, who represented a percentage of 80% of the research community. After processin
... Show MoreBackground: Determination of local bone mineral density (BMD) with cortical thickness and bone height may offer a comprehensive description of the bone the surgeon will encounter when he or she actually sets the implant. Quantitative computed tomography (CT) (i.e., quantitative interpretation of values derived from Hounsfield units with a suitable calibration procedure) is the modality of choice to determine BMD. The aim of the present clinical study is to determine the local bone density in dental implant recipient sites using computerized tomography. Material and method: The sample consisted of (72) Iraqi patients whom referred to Al-Kharkh General hospital, Spiral CT scan Department for bone quality and quantity assessment after one wee
... Show MoreIn this study, some attenuation parameters of gamma shields were studied. This shields consisting of composite materials of Unsaturated polyester as a base material and Nano iron oxide (Fe2O3) and, micro iron (Fe) as reinforcement materials at different percentages (1, 3,5,7and 9)wt%, and with different thickness (1, 1.5, 2, 2.5, 3, 3.5and 4) cm. The results showed that the use of nanoparticles is better than the microparticales in the field of radiation shielding. It has been shown that the values of attenuation parameters of gamma it bitter in the case of nanoparticles than case of the use of micro material.
The following dilutions -710X46, -610X46, -510X46 of Bacillus thuringiensis were used for bioassay against the different larval instar of the potato tuber moth Phthorimaea operculella by the spraying method, the results showed that there was no significant influence in the percentage of egg hatching in comparison with the control. The sensitivity of larval stages was reduced with the increasing the age and exposure period. The study also showed that the larvae infected with B.t. stopped feeding, movement and a general paralysis causing the death of larva after (24-48) hours , and the larva color was changed from the natural waxy colour to brown finally to the black after death.
The present study aims at answering the following questions:.
1-Which is more effective in enriching students. Vocabulary ,the use of short stories or the traditional way?
2-What extent has the use of short stories an effect upon the students. achievement in vocabulary test?
3- Is there any significant difference between the male and female student of the experimental group in vocabulary achievement test?
 
... Show MoreThe following dilutions -710X46, -610X46, -510X46 of Bacillus thuringiensis were used for bioassay against the different larval instar of the potato tuber moth Phthorimaea operculella by the spraying method, the results showed that there was no significant influence in the percentage of egg hatching in comparison with the control. The sensitivity of larval stages was reduced with the increasing the age and exposure period. The study also showed that the larvae infected with B.t. stopped feeding, movement and a general paralysis causing the death of larva after (24-48) hours , and the larva color was changed from the natural waxy colour to brown finally to the black after death.
In the present work, heterojunction diode detectors will be prepared using germanium wafers as a substrate material and 200 nm tin sulfide thickness will be evaporated by using thermal evaporation method as thin film on the substrate. Nd:YAG laser (λ=532 nm) with different energy densities (5.66 J/cm2 and 11.32 J/cm2) is used to diffuse the SnS inside the surface of the germanium samples with 10 laser shots in different environments (vacuum and distilled water). I-V characteristics in the dark illumination, C-V characteristics, transmission measurements, spectral responsivity and quantum efficiency were investigated at 300K. The C-V measurements have shown that the heterojunction were of abrupt type and the maximum value of build-in pot
... Show MoreSports skills in some individual games require physical and motor qualities to facilitate the process of skill performance and also require the instructor or trainer to use more than one strategy, method and way to bring the performance to the level of mastery and avoid injury. The aim of the research is to know the effect of using special exercises using tools and their effect on teaching the skill of a front shoulder circle. The research hypothesis is that using special exercises with tools has a positive effect on teaching the skill of a front shoulder circle on the rings apparatus. Research method: - The researchers used the experimental method by designing two equal groups, the control and the experimental, to suit the research
... Show MoreBackground: A Temporomandibular joint (TMJ) internal derangement (TMJID) is a disruption within the internal aspects of the TMJ in which the disc is displaced from its normal functional relationship with the mandibular condyle, after which the articular portion of the temporal bone causes joint dysfunction, joint sound, malocclusion, and locking of the mouth. Conservative and invasive techniques can be used for the treatment of TMJID. A platelet-rich plasma (PRP) injection is a simple, less invasive surgical procedure for the treatment of internal derangement. The objective of this study was to evaluate the efficacy of PRP injections in decreasing or eliminating pain, clicking, and limitation of mouth opening in patients with TMJID after th
... Show More