Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician could precisely predict the primary stability of an implant on insertion with different surgical procedures using his own tactile perception. Materials and methods: A total of (60) Iraqi adult patients, (28) males and (32) females, age ranged (22-66) years old were enrolled in this clinical prospective study. The maximum torque value recorded on implant insertion using calibrated manual torque ratchet adopting three categories: low (10 to 30 N/cm), medium (30 to 50 N/cm), and high insertion torque (50 to 70 N/cm). The oral surgeon was asked to indicate the perceived ISQs values according to his perception then Implant stability quotient were measured by Osstell ™. Bone density (type) was determined according to subjective bone resistance encountered while drilling as proposed by Lekohlm and Zarb. Results: A total of 160 implants were inserted. The mean peak IT value was 49 ± 2.61N/cm. The mean ISQ value was 71.7 ± 8.86. Statistical analysis show a significant correlation between ISQ values and PIT values (P<0.001) , between IT values and bone types and between perceived primary stability and actual primary stability (P<0.001) . Conclusions:The corresponding significant correlations between insertion torque, and ISQ values may help clinicians to predict primary stability on implant insertion, that may be associated with implant survival and success rates. A moderate reliability (correlation) between perceived ISQ values and those measured using RF analyzer(Ossttel device).
In this study, polymeric coating was developed by incorporating nano graphene in the polymer blend with applications to oil storage tanks. The oil storage tanks samples were brought from the oil Pipeline Company / Doura refinery in Baghdad. The coating polymer was formed with a blend (epoxy resin and repcoat ZR). The proportion of mixing the mixture was 3:1:1 epoxy resin 21.06 gm: repcoat ZR 10.53 gm: hardener 10.53 gm. The blend/graphene was prepared using in stui-polymerization method with different weight percentage 1, 3, 5, and 7 wt % added to blend. The resulting solution was put in a glass tube on a magnetic stirrer for one hour at a temperature of 40 °C. The result of contact angle and wate
... Show MoreBackground: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2
... Show MoreThe educational sector is one of the important sectors in the world, and it is considered one of the means of community development. In addition, it is one of the means of making the country’s renaissance and devel-opment because it represents the factory of thinking minds that make change. There is no doubt that this sector is the same as any other sector. The deficit in the studied scientific planning has been prolonged, which led to its deterioration, and the problems of education remain diverse and inherited from previous time periods, where the hierarchical cluster analysis was used on postgraduate students in universities in Iraq, except for Kurdistan region, and the number of universities that were included in the study was
... Show MoreThe New Schiff base ligand 4,4'-[(1,1'-Biphenyl)-4,4'-diyl,bis-(azo)-bis-[2-Salicylidene thiosemicarbazide](HL)(BASTSC)and its complexes with Co(II), Ni(II), and Cu(II) were prepared and characterized by elemental analysis, electronic, FTIR, magnetic susceptibility measurements. The analytical and spectral data showed, the stiochiometry of the complexes to be 1:1 (metal: ligand). FTIR spectral data showed that the ligand behaves as dibasic hexadentate molecule with (N, S, O) donor sequence towards metal ions. The octahedral geometry for Co(II), Ni(II), and Cu(II) complexes and non electrolyte behavior was suggested according to the analysis data.
The present study include a new developed method of analysis for determination of drug Spironolaction (SP) in some Pharmaceuticals by Spectrofluorometric method. Spironolaction was determined under optimal experimental condition that follows :- The excitation spectrum was (l=351 nm), the emmetion spectrum was (l=518 nm), pH=1, the suitable temperature for reaction 60oC and the optimal time less than (3) minute. The analysis and rang statistical data was:-Linear dynamic rang (1-10) ?g.ml-1, the detection limit (D.L = 0.023 ?g.ml-1), Molar absorptivity (? = 29875 liter mole-1 cm-1), Relative standard deviation (%RSD = 0.78), (%Erel = 3.3) and recovery (Rec = 96.6) percentage. Determination of Spironolactone was accomplished by two methods
... Show MoreOne of the critical factors for dental implant success is accurate clinical and radiological assessment. Cone-beam computed tomography systems (CBCT) allow surgeons to determine the quality and quantity before surgery, aiding in treatment planning. This study highlights the importance of such an assessment Materials and Methods A total of 40 patients were referred to CBCT scanning for pre-dental implant assessment in the Oral and Maxillofacial Radiology department at Al-Shaheed Gazi Al Hariri Hospital from 2021 to 2022. The patients were between 18 and 50 years old. All data were analyzed with on-demand 3D software (Kavo OP 3D: Cone Beam 3D imaging Germany). Results: Regarding the ridge shape: In the upper anterior and posterior regions, th
... Show MoreSemi-parametric models analysis is one of the most interesting subjects in recent studies due to give an efficient model estimation. The problem when the response variable has one of two values either 0 ( no response) or one – with response which is called the logistic regression model.
We compare two methods Bayesian and . Then the results were compared using MSe criteria.
A simulation had been used to study the empirical behavior for the Logistic model , with different sample sizes and variances. The results using represent that the Bayesian method is better than the at small samples sizes.
... Show MoreAim: The Aim of the study is to compare between Er,Cr:YSGG 2780 nm laser and carbide fissure bur in root-end resection regarding the morphological variations, temperature changes and the duration of resection process.
Settings and Design: 5 W, 25 Hz, 50% water, 80% air,25.47 J/cm2 .
Material and method: twenty-one extracted single rooted teeth endodontically were treated, twenty teeth were obturated and divided into two groups according to method of resection. Group 1 root-end resected using cross cut carbide bur while group 2 root-end resected using laser with MGG6 sapphire tip of 600 μm diameter. Temperature on external root surface and duration of resection were recor
... Show More