Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician could precisely predict the primary stability of an implant on insertion with different surgical procedures using his own tactile perception. Materials and methods: A total of (60) Iraqi adult patients, (28) males and (32) females, age ranged (22-66) years old were enrolled in this clinical prospective study. The maximum torque value recorded on implant insertion using calibrated manual torque ratchet adopting three categories: low (10 to 30 N/cm), medium (30 to 50 N/cm), and high insertion torque (50 to 70 N/cm). The oral surgeon was asked to indicate the perceived ISQs values according to his perception then Implant stability quotient were measured by Osstell ™. Bone density (type) was determined according to subjective bone resistance encountered while drilling as proposed by Lekohlm and Zarb. Results: A total of 160 implants were inserted. The mean peak IT value was 49 ± 2.61N/cm. The mean ISQ value was 71.7 ± 8.86. Statistical analysis show a significant correlation between ISQ values and PIT values (P<0.001) , between IT values and bone types and between perceived primary stability and actual primary stability (P<0.001) . Conclusions:The corresponding significant correlations between insertion torque, and ISQ values may help clinicians to predict primary stability on implant insertion, that may be associated with implant survival and success rates. A moderate reliability (correlation) between perceived ISQ values and those measured using RF analyzer(Ossttel device).
The varied applications of polystyrene in various fields of life led to examining the cause of radiation influence on some rheological behavior of commercial Polystyrene (PS) solution in the chloroform (CHCl3) solvent. Polystyrene grains shape samples were irradiated using the radioactive element Cesium- 137 with (9 µci) activity for 10, 20, and 30 minutes. The viscosity of the polymer solution depends on the concentration and size (i.e. molecular weight) of the dissolved polymer. Experimental data showed that the radiation dose affected the value of viscosity (shear, relative, specific, and reduced). The viscosity value significantly reduced at 10 min radiation dose and when increasing the dose, the viscosity value increased
... Show MoreOrganizations must interact with the environment around them, so the environment must be suitable for that interaction. These companies are now trying to become Learning Organizations because it try to face that challenges may rise from its environments. The Learning Organization is a concept that is becoming an increasingly widespread philosophy in modern companies, from the largest multinationals to the smallest ventures. What is achieved by this philosophy depends considerably on one's interpretation of it and commitment to it. This study gives a definition that we felt was the true ideology behind the Learning Organization and Group Working. A Learning Organization is one in which people at all levels
... Show MoreOilwell cementing operations are crucial for drilling and completion, preserving the well's productive life. However, weak and permeable formations pose a high risk of cement slurry loss, leading to failure. Lightweight cement, like foamed cement, is used to avoid these difficulties. This study is focused on creating a range of foamed slurry densities and examining the effect of gas concentration on their rheological properties. The foaming agent and foam stabilizer are tested, and the optimal concentration is determined to be 2% and 0.12%, respectively, by the weight of the cement.
Furthermore, the construction of samples of foam cement with different densities (0.8, 1.0, 1.2, 1.4, and 1.6) g/cc is performed to f
... Show MorePolyethersulfone (PES) ultrafiltration membrane blending NaX zeolite crystals as a hydrophilic additive was examined for zinc (II) and lead ions Pb (II) removal from aqueous solutions. The effect of NaX zeolite content on the permeation flux and removal efficiency was studied. The results showed that adding zeolite to the polymer matrix enhanced the permeation flux. The permeation flux of all the zeolite/PES matrix membranes was higher than the pristine membrane. No significant improvement was observed in the removal of Zn (II) ions using all prepared membranes as the removal percentage did not raise above 29.2%. However, the removal percentage of Pb (II) ions was enhanced to 97% using a membrane containing 0.9%wt. zeolite. Also, it was
... Show MoreBackground: Normal occlusal features of primary dentition are crucial for normal development of the permanent dentition. Breastfeeding is an important factor for both general and dental health of children. Aim: The aim of the present study is to assess the impact of the breastfeeding duration on the prevalence of normal occlusal features of the primary dentition among preschool children in Baghdad. Materials and Methods: The sample was 630 Iraqi children (270- boys, 360 girls), aged 3-5 years selected from four kindergartens in Baghdad city. The study was carried out through questionnaire and clinical examination. Normal occlusal features were examined as the presence or absence of interincisive spaces (IS) and primate spaces (PS), termi
... Show MoreAn easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,
... Show MoreThis paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70?l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 ?g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.
Simple, cheap, sensitive, and accurate kinetic- spectrophotometric method has been developed for the determination of naringenin in pure and supplements formulations. The method is based on the formation of Prussian blue. The product dye exhibits a maximum absorbance at 707 nm. The calibration graph of naringenin was linear over the range 0.3 to 10 µg ml-1 for the fixed time method (at 15 min) with a correlation coefficient (r) and percentage linearity (r2%) were of 0.9995 and 99.90 %, respectively, while the limit of detection LOD was 0.041 µg ml-1. The method was successfully applied for the determination of naringenin in supplements with satisfac
... Show MoreFilms of pure Poly (methyl methacrylate) PMMA and Iron chromate doped PMMA have been prepared using casting method. Transmission and absorptance spectra have been recorded in the wavelength range (300-900) nm, in order to calculate, single oscillator energy, dispersion energy proposed by Wemple - DiDomenico model, average oscillator strength, average oscillator wavelength. The refractive index data at infinite wavelength which was found to obey single oscillator model which was found to increase from 2.27-2.56 as the doping percentage increase. The decreasing in the optical energy gap which was found according to Tauc model were (3.74-3.63) eV , is in good agreement with that obtained by wimple-DiDomenico model. The inverse behavior comp
... Show More