Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician could precisely predict the primary stability of an implant on insertion with different surgical procedures using his own tactile perception. Materials and methods: A total of (60) Iraqi adult patients, (28) males and (32) females, age ranged (22-66) years old were enrolled in this clinical prospective study. The maximum torque value recorded on implant insertion using calibrated manual torque ratchet adopting three categories: low (10 to 30 N/cm), medium (30 to 50 N/cm), and high insertion torque (50 to 70 N/cm). The oral surgeon was asked to indicate the perceived ISQs values according to his perception then Implant stability quotient were measured by Osstell ™. Bone density (type) was determined according to subjective bone resistance encountered while drilling as proposed by Lekohlm and Zarb. Results: A total of 160 implants were inserted. The mean peak IT value was 49 ± 2.61N/cm. The mean ISQ value was 71.7 ± 8.86. Statistical analysis show a significant correlation between ISQ values and PIT values (P<0.001) , between IT values and bone types and between perceived primary stability and actual primary stability (P<0.001) . Conclusions:The corresponding significant correlations between insertion torque, and ISQ values may help clinicians to predict primary stability on implant insertion, that may be associated with implant survival and success rates. A moderate reliability (correlation) between perceived ISQ values and those measured using RF analyzer(Ossttel device).
The objective of this study is to evaluate the efficacy and safety of rowatinex and tamsulosin in the treatment of patients with ureteric stone.
Forty patients with ureteric stone ranged (4- 12) mm, were included in this study. They were randomized into two groups where the first group includes twenty patients treated with Rowatinex three times daily (Group 1), and the second group includes twenty patients treated with tamsulosin 0.4mg/day (Group 2). All patients were randomly assigned to receive the designed standard medical therapy for a maximum of 3 weeks.
Each group was given an antibiotic as prophylaxis and an injectable non-steroidal anti-inflammatory drug used on demand. At the outpatient clinic all subjects were a
... Show MoreIn this study, a Hydroxyapatite (HA) coating was prepared on a titanium implant by an electrochemical deposition process. The titanium pre-treatment by anodizing in 1.65 mol/L sulfuric acid with (10V) at room temperature. The deposition was all conducted at a constant voltage of 6.0 V, for 1 h at room temperature. The coatings thus prepared were characterized with Fourier transform infrared spectroscopy (FTIR) and thickness of the coated layer.The electrochemical deposition of HA occurred on the titanium as a cathode. Coated titanium by HA after anodizing revealed a good corrosion protection efficiency even at a temperature ranged (293-323) K in artificial saliva. Activation energy and pre-exponential factor (kinetic parameters) were calcul
... Show MoreBiological activity of the carotenoids which are produced fromchemically-mutaed local isolate of Rhodotorula mucilaginosawas studied. The results showed variation of inhibition activity of caritenoids against different types of pathogenic bacteria include, Staph aureus, E. coli, B. subtilis and Salmo. typh., the number declined from 2×107cell/ml to 2×104, 5×104, 2×105, 9×105 cell/ml respectively after 24hour. The produced carotenoids from alocal mutant Rhodotorula mucilaginosa revealed an antioxidant activity as free radical removal of 85.6%. Carotinoides revealed a highest stability in petroleum ether solvent for 30 days at room temperature. It found that the pigment was more stability in sesame oil compared with sun flower and coc
... Show MoreSome microorganisms can produce nanocellulose, which is known as bacterial nanocellulose (BNC); the most active bacterial producer is acetic acid bacteria (AAB), which is a gram-negative, motile and obligate aerobic belongs to the family Acetobacteraceae. Bacterial nanocellulose has excellent attention in medical (surgical domain), industrial and pharmaceutical fields because of its flexible properties, characteristics and advantages. So, in this study, the AAB (5AC) isolate was isolated from apple vinegar. The production of BNC was performed by using a natural medium called palm dates liquid medium, the produced bacterial Cellulose was purified by using the sodium hydroxide method; it was observed that the wet weight of the BNC was a
... Show MoreBackground: Bone density is a major factor that affect mini implant primarily stability; no Iraqi studies have evaluated bone density related to mini-implant placement for orthodontic anchorage at age 13 -15 years. The present research aims to evaluate gender, side and site differences in the bone density at various orthodontic implant sites for the maxillary alveolar bone. Materials and methods: Twenty nine individuals (16 males and 13 females) had subjected to clinical examination, then 64-multislice computed tomography scan data were evaluated and bone density was measured in Hounsfield unit at 21 points (9 points for each side and 3 points between the right and left central incisors) . Results: The results obtained showed that there ar
... Show MoreConditional logistic regression is often used to study the relationship between event outcomes and specific prognostic factors in order to application of logistic regression and utilizing its predictive capabilities into environmental studies. This research seeks to demonstrate a novel approach of implementing conditional logistic regression in environmental research through inference methods predicated on longitudinal data. Thus, statistical analysis of longitudinal data requires methods that can properly take into account the interdependence within-subjects for the response measurements. If this correlation ignored then inferences such as statistical tests and confidence intervals can be invalid largely.
Background The application of nanotechnology to biomedical surfaces is explained by the ability of cells to interact with nanometric features. The aim of this study was to consider the role of nanoscale topographic modification of CPTi dental implant using chemical etching method for the purpose of improving osseointegration. Materials and methods: Commercial pure titanium rod was machined into 20 dental implants. Each implant was machined in diameter about 3mm, length of 8mm (5mm was threaded part and 3mm was flat part). Implants were prepared and divided into 2 groups according to the types of surface modification method used: 1st group (10 implant) remained without nano surface modification (control), 2nd group include (10 implant) etche
... Show MoreThis study aims to fabricate and assess the β-tricalcium phosphate (β-TCP) bioactive ceramic coat layer on bioinert ceramic zirconia implants through the direct laser melting technique by applying a long-pulsed Nd:YAG laser of 1064 nm. Surface morphologies, adherence, and structural change in the coatings were evaluated by optical microscopy, field emission scanning electron microscope, hardness, and x-ray diffractometer. The elastic modulus (EM) of the coating was also determined using the nanoindentation test. The quality of the coating was improved when the laser power was 90 W with a decrease in the scan speed to 4 mm s−1. The chemical composition of the coat was maintained after laser processing; also, the Energy Dispersive
... Show MoreBackground: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium
... Show More