Determination of Implant Primary Stability: A Comparison of the Surgeon’s Tactile Sense and Objective Measurements
...Show More Authors

Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician could precisely predict the primary stability of an implant on insertion with different surgical procedures using his own tactile perception. Materials and methods: A total of (60) Iraqi adult patients, (28) males and (32) females, age ranged (22-66) years old were enrolled in this clinical prospective study. The maximum torque value recorded on implant insertion using calibrated manual torque ratchet adopting three categories: low (10 to 30 N/cm), medium (30 to 50 N/cm), and high insertion torque (50 to 70 N/cm). The oral surgeon was asked to indicate the perceived ISQs values according to his perception then Implant stability quotient were measured by Osstell ™. Bone density (type) was determined according to subjective bone resistance encountered while drilling as proposed by Lekohlm and Zarb. Results: A total of 160 implants were inserted. The mean peak IT value was 49 ± 2.61N/cm. The mean ISQ value was 71.7 ± 8.86. Statistical analysis show a significant correlation between ISQ values and PIT values (P<0.001) , between IT values and bone types and between perceived primary stability and actual primary stability (P<0.001) . Conclusions:The corresponding significant correlations between insertion torque, and ISQ values may help clinicians to predict primary stability on implant insertion, that may be associated with implant survival and success rates. A moderate reliability (correlation) between perceived ISQ values and those measured using RF analyzer(Ossttel device).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Determination and evaluation of principal minerals in Negella sativa by atomic absorption technical methods
...Show More Authors

Determination and evaluation of principal minerals in Negella sativa by atomic absorption technical methods were showed, using wet ashing method. This work was done on Negella sativa because of wide using of this plant in many formulations ( in food or medicine ).two types of atomic absorptions were used : first, flame atomic absorption spectroscopy, for minerals of high concentrations such as, Na, Mg, K, Fe, Ca, Li, Ni, Zn, Mn, Cu. Second, flameless atomic absorption spectroscopy, for minerals of low concentrations such as, Al, Si, V, B, Pb, Co, Cd, Cr ,Si, Hg, Sn .The results showed the existence of many minerals in Negella sativa useful to human sanity with acceptable dietary allowance. On other side, the presence of harmful m

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Determination of Cefalexin by Direct (UV- Vis) Spectrophotometer and Indirect(Flame Atomic Absorption) Technique
...Show More Authors

         A new method for the determination of the drug cefalexin in some Pharmaceuticals using (UV-Vis) and  indirect Flame Atomic Absorption Spectrophotometer (FAAS) , Fe III should forms a chelating complex with cefalexin (CEX –Fe III) at pH (1-8) and the best pH for the formation of (CEX –Fe III) chelating complex was (2) .The complex extracted with Methanol  and  Dimethy-Sulphoxide .The mole-ratio method has been used to determine the structure of chelate (CEX - Fe III) and found to be 2:1 LM ( Ligand : Metal.) .

Keywords : Cefalexin , chelating complex.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Baghdad Science Journal
Simultaneous Ratio Derivative Spectrophotometric Determination of Paracetamol, Caffeine and Ibuprofen in Their Ternary Form
...Show More Authors

A new, accurate, precise and economic two spectrophotometric methods for determination of Paracetamol (Par), Ibuprofen (Ibu), and Caffeine (Caf) were suggested. Those methods were the first and second ratio derivative spectrum using a double devisor. Par, Ibu, and Caf showed many useful peaks for their quantified determination. The validity of all analysis modes for determination of the three compounds, peak to baseline, peak area and peak to peak were according to ICH. The linearity of two methods was between 5 µg/ml as a lower concentration and 50 µg/ml as the highest concentration for three compounds. Recovery percentage was around 100% and relative standard deviation was less than 2.6%. The methods were applied successfully in the

... Show More
View Publication Preview PDF
Scopus (15)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Reservoir Hydraulic Flow Units and Permeability Estimation Using Flow Zone Indicator Method
...Show More Authors

   Reservoir characterization plays a crucial role in comprehending the distribution of formation properties and fluids within heterogeneous reservoirs. This knowledge is instrumental in constructing an accurate three-dimensional model of the reservoir, facilitating predictions regarding porosity, permeability, and fluid flow distribution. Among the various methods employed for reservoir characterization, the hydraulic flow unit stands out as a widely adopted approach. By effectively subdividing the reservoir into distinct zones, each characterized by unique petrophysical and geological properties, hydraulic flow units enable comprehensive reservoir analysis. The concept of the flow unit is closely tied to the flow zone indicator, a cr

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Jul 22 2020
Journal Name
International Journal Of Research In Pharmaceutical Sciences
Cloud point extraction method for the sensitive determination of metoclopramide hydrochloride in pharmaceutical dosage forms
...Show More Authors

In this work, a simple and very sensitive cloud point extraction (CPE) process was developed for the determination of trace amount of metoclopramide hydrochloride (MTH) in pharmaceutical dosage forms. The method is based on the extraction of the azo-dye results from the coupling reaction of diazotized MTH with p-coumaric acid (p-CA) using nonionic surfactant (Triton X114). The extracted azo-dye in the surfactant rich phase was dissolved in ethanol and detected spectrophotometrically at λmax 480 nm. The reaction was studied using both batch and CPE methods (with and without extraction) and a simple comparison between the two methods was performed. The conditions that may be affected by the extraction process and the sensitivity of m

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Indian Journal Of Natural Sciences
Determination of the Electron Density Variation for Ionosphere Layer Over Iraqi Zone Using IRI Model
...Show More Authors

KA Hadi, AH Asma’a, IJONS, 2018 - Cited by 1

View Publication
Publication Date
Thu Sep 01 2011
Journal Name
Journal Of Economics And Administrative Sciences
Determination Of The Efficient Production Plans For Al-Shaheed Public Company By Using Tatget Motad Model Under Risk And Uncertainty
...Show More Authors

The research aims to derive the efficient industrial plans for Al – shaheed public company under risk by using Target MOTAD as a linear alternative  model for the quadratic programming models.

The results showed that there had been a sort of (trade- off) between risk and the expected gross margins. And if the studied company strives to get high gross margin, it should tolerate risk and vice versa. So the management  of Al- Shaheed Company to be invited to apply the suitable procedures in the production process, in order to get efficient plans that improves it's  performance .

View Publication Preview PDF
Crossref
Publication Date
Sat Mar 01 2014
Journal Name
Food Chemistry
Micro-solid phase extraction with liquid chromatography–tandem mass spectrometry for the determination of aflatoxins in coffee and malt beverage
...Show More Authors

A single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography–tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20 mg; extraction time, 90 min; stirring speed, 1000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1

... Show More
View Publication
Scopus (65)
Crossref (64)
Scopus Clarivate Crossref
Publication Date
Thu Nov 05 2020
Journal Name
Methods And Objects Of Chemical Analysis
Derivative Spectrophotometric Determination for Simultaneous Estimation of Isoniazid and Ciprofloxacin in Mixture and Pharmaceutical Formulation
...Show More Authors

A simple analytical method was used in the present work for the simultaneous quantification of Ciprofloxacin and Isoniazid in pharmaceutical preparations. UV-Visible spectrophotometry has been applied to quantify these compounds in pure and mixture solutions using the first-order derivative method. The method depends on the first derivative spectrophotometry using zero-cross, peak to baseline, peak to peak and peak area measurements. Good linearity was shown in the concentration range of 2 to 24 µg∙mL-1 for Ciprofloxacin and 2 to 22 µg∙mL-1 for Isoniazid in the mixture, and the correlation coefficients were 0.9990 and 0.9989 respectively using peak area mode. The limits of detection (LOD) and limits of quantification (LOQ) were

... Show More
Publication Date
Sun Jun 02 2019
Journal Name
Baghdad Science Journal
Micro Spectrophotometric Determination and Cloud Point Extraction of Sulphadimidine Sodium in Pure form and Pharmaceutical Drug
...Show More Authors

Two simple, rapid, and useful spectrophotometric methods were suggest or the determination of sulphadimidine sodium (SDMS) with and without using cloud point extraction technique in pure form and pharmaceutical preparation. The first  method was based on  diazotization of the Sulphdimidine Sodium drug by sodium nitrite at 5 ºC, followed by coupling with α –Naphthol in basic medium to form an orange colored product . The product was stabilized and its absorption was measured at 473 nm. Beer’s law was obeyed in the concentration range of (1-12) μg∙ml-1. Sandell’s sensitivity was 0.03012 μg∙cm-1, the detection limit was 0.0277 μg∙ml-1, and the limit of Quantitation was 0.03605μg

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (6)
Scopus Clarivate Crossref