Preferred Language
Articles
/
jbcd-2379
The Effect of Oral Contraceptive Pill on Cortical Thickness and Bone Mineral Density of The Mandibular Mental and Gonial Regions in Premenopausal Females Using Spiral Computed Tomography
...Show More Authors

Background: Prolonged use of low-dose estrogen ''20 micrograms or less" Combined oral contraceptive pill (that have estrogen and progesterone steroid hormone) had an effect on bone turnover .Bone mineral density is used in clinical medicine as an indirect indicator of osteoporosis and fracture risk. The aim of the study: The aim of this study was to investigate the effect of low dose oral contraceptive pill on the cortical thickness (in millimeter) and bone mineral density at the mandibular cortex of mental and gonial regions in Hounsfield unit(HU) using spiral computed tomography. Material and method: This prospective study was conducted on computed tomographic image of 100 women aged between (20-40) years .The collected sample includes patients attended for different diagnostic purposes to AL-Shaheed Al-Seder Teaching General Hospital of Al-Najaf AL-Ashraf from Julay, 2015 to May 2016.Data were grouped into two categories :group (1)control group (don't use combined oral contraceptive pill) (n=50);group(2)women taking low dose(20microgram) combined oral contraceptive pill for more than 2 years,(n=50).Cortical thickness measured in millimeter and Bone Mineral Density measured in Hounsfield unit both in mental foramen and gonial angle regions .Physical activity number of parity type of lactation were documented by questionnaire. Result: There was a statically significant difference; in cortical thickness p=0.037 and bone mineral density P=0.007 in mental area between the two groups ;the lowest mean in group (2)and highest mean in group(1) . After adjustment for age ,number of parity, and physical activity measurement scores ,there was a significant difference p=0.001 in mean of bone mineral density and p=0.065 for cortical thickness of gonial angle between the two groups ;the highest mean in group (1) and lowest mean in group (2). CONCLUSION: Computed tomography is a good diagnostic method to measure the value of cortical thickness and bone mineral density simultaneously in mental and gonial region of the mandible in premenopausal female using low dose combined oral contraceptive pill which have small effect on bone ;depended on the woman's age and the duration of using the pill ;that did not appear until about two years of use.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun May 05 2013
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
The Effect Of Aqueous Extract Of Anastatica Hierochuntica On Some Hormones In Mouse Females
...Show More Authors

Anastatica hierochuntica is believed to be very useful in Arab countries for treating various health disorders. The aqueous extract of Anastatica hierochuntica was investigated for its effects on hormones in mice females. the aqueous extract of plant at a dose level of 100mg/1mL showed significant increase (p<0.05) on levels of hormones LH, FSH, PRL level and PRO level. Clomid treated group showd significant increase in LH, FSH, and PRL while there was non-significant increase in PRO. From the above results, it is concluded for the first time that aqueous Anastatica hierchuntica extract offers significant effect of LH, FSH, PRL, and PRO in this mice females scompared with control.

Publication Date
Sun Sep 07 2008
Journal Name
Baghdad Science Journal
Study the effect of thickness and annealing temperature on the Electrical Properties of CdTe thin Films
...Show More Authors

The electrical properties of polycrystalline cadmium telluride thin films of different thickness (200,300,400)nm deposited by thermal evaporation onto glass substrates at room temperature and treated at different annealing temperature (373, 423, 473) K are reported. Conductivity measurements have been showed that the conductivity increases from 5.69X10-5 to 0.0011, 0.0001 (?.cm)-1 when the film thickness and annealing temperature increase respectively. This increasing in ?d.c due to increasing the carrier concentration which result from the excess free Te in these films.

View Publication Preview PDF
Crossref
Publication Date
Sun Apr 30 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Study the Effect of Thickness on the Electrical Conductivity and Optical Constant of Co3O4 Thin Films
...Show More Authors

 In this research the Cobalt Oxide (Co3O4) films are prepared by the method of chemical spray pyrolysis deposition at different thicknesses such that (250, 350, 450, and 550) ± 20 nm.      The optical measurement shows that the Co3O4 films have a direct energy gap, and they in general increase with the increase of the thickness. The optical constants are investigated and calculated such as absorption coefficient, refractive index, extinction coefficient and the dielectric constants for the wavelengths in the range (300-900) nm.     The electrical conductivity (σ) and the activation energies (Ea1, Ea2) have been investigated on (Co3O4) thin films as a function of thickness. The films

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
The effect of thickness on the optical properties of Cu2S thin films
...Show More Authors

In this work, the optical properties of Cu2S with different thickness
(1400, 2400, 4400) Ǻ have been prepared by chemical spray pyrolys
is method onto clean glass substrate heated at 283 oC ±2. The effect
of thickness on the optical properties of Cu2S has been studied. It
was found that the optical properties of the electronic transitions on
fundamental absorption edge were direct allowed and the value of the
optical energy gap of Cu2S (Eg) for direct transition decreased from
(2.4-2.1) eV with increasing of the thickness from (1400 - 4400)Ǻ
respectively. Also it was found that the absorption coefficient is
increased with increasing of thicknesses. The optical constants such<

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Craniofacial Surgery
Evaluation of the Trephine Method in Harvesting Bone Graft From the Anterior Iliac Crest for Oral and Maxillofacial Reconstructive Surgery
...Show More Authors

View Publication
Scopus (14)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Sun May 04 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Craniometric asymmetry assessment in class I and class II skeletal relationship patients using helical computed tomography sample aged between 18-35 years
...Show More Authors

Background: Asymmetry assessment is an important component of orthodontic diagnosis and treatment planning. Several studies attempted to find the relationship between craniometric asymmetry and skeletal jaws relationship and many authors found some extent of asymmetry in individuals with normal jaws relationship. The use of Computed tomography (CT) allows for the assessment of asymmetry on a dimensionally accurate volumetric image, aim of the study is to determine if there are differences in craniometric asymmetry between patient with skeletal class I and patients with skeletal class II relationship using Helical CT scan. Materials and Methods: Ninety individuals with clinically symmetrical faces were imaged with Helical CT scan, and aging

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
The effect of current density on the structures and photoluminescence of n-type porous silicon
...Show More Authors

Porous silicon (PS) layers were formed on n-type silicon (Si) wafers using Photo- electrochemical Etching technique (PEC) was used to produce porous silicon for n-type with orientation of (111). The effects of current density were investigated at: (10, 20, 30, 40, and50) mA/cm2 with etching time: 10min. X-ray diffraction studies showed distinct variations between the fresh silicon surface and the synthesized porous silicon. The maximum crystal size of Porous Silicon is (33.9nm) and minimum is (2.6nm) The Atomic force microscopy (AFM) analysis and Field Emission Scanning Electron Microscope (FESEM) were used to study the morphology of porous silicon layer. AFM results showed that root mean square (RMS) of roughness and the grain size of p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 20 2021
Journal Name
Journal Of Craniofacial Surgery
Presurgical Assessment of Anatomical Landmark Position Using Two Views of Cone Beam Computed Tomography: A Comparative Radiological Study
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun May 04 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of tooth shape ratio on mandibular incisors arrangement in Iraqi adult subjects
...Show More Authors

Background: This study aimed to assess the effect of tooth shape ratio on mandibular incisor arrangement. Materials and methods: The sample included dental casts of some dental students and orthodontic patients having Class I dental and skeletal patterns with normal occlusion and severe crowding. The sample was divided into two groups according to the severity of crowding into: group I had Class I normal occlusion with mild or no crowded mandibular dentition and group II had Class I malocclusion with severe crowded mandibular dentition. Each group comprising of 40 subjects (20 males and 20 females). The mesio-distal and facio-lingual crown diameters were measured manually for each cast using modified vernier caliper gauge. Descriptive sta

... Show More
View Publication Preview PDF
Publication Date
Sun May 04 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A Micro Computed Tomography Assessment of New Carrier-Based Root Canal Fillings
...Show More Authors

Background: The main aim of the present study is to qualify and quantify voids formation of root canals obturated with GuttaCore (GC) and experimental Hydroxyapatite polyethylene (HA/PE) as new carrier-based root canal fillings by using micro computed tomography scan. Materials and methods: In the present study, eight straight single-rooted human permanent premolar teeth are selected and disinfected, then stored in distilled water. The teeth decoronated leaving a root length of 12mm each. The root canals instrumented by using crown down technique and the apical diameter of the root canal prepared to a size # 30/0.04 for achieving standardized measurements. A 5mL of 17% EDTA used to remove the smear layer followed by 5mL of 2.5% NaOCl and r

... Show More
View Publication Preview PDF