Background: Prolonged use of low-dose estrogen ''20 micrograms or less" Combined oral contraceptive pill (that have estrogen and progesterone steroid hormone) had an effect on bone turnover .Bone mineral density is used in clinical medicine as an indirect indicator of osteoporosis and fracture risk. The aim of the study: The aim of this study was to investigate the effect of low dose oral contraceptive pill on the cortical thickness (in millimeter) and bone mineral density at the mandibular cortex of mental and gonial regions in Hounsfield unit(HU) using spiral computed tomography. Material and method: This prospective study was conducted on computed tomographic image of 100 women aged between (20-40) years .The collected sample includes patients attended for different diagnostic purposes to AL-Shaheed Al-Seder Teaching General Hospital of Al-Najaf AL-Ashraf from Julay, 2015 to May 2016.Data were grouped into two categories :group (1)control group (don't use combined oral contraceptive pill) (n=50);group(2)women taking low dose(20microgram) combined oral contraceptive pill for more than 2 years,(n=50).Cortical thickness measured in millimeter and Bone Mineral Density measured in Hounsfield unit both in mental foramen and gonial angle regions .Physical activity number of parity type of lactation were documented by questionnaire. Result: There was a statically significant difference; in cortical thickness p=0.037 and bone mineral density P=0.007 in mental area between the two groups ;the lowest mean in group (2)and highest mean in group(1) . After adjustment for age ,number of parity, and physical activity measurement scores ,there was a significant difference p=0.001 in mean of bone mineral density and p=0.065 for cortical thickness of gonial angle between the two groups ;the highest mean in group (1) and lowest mean in group (2). CONCLUSION: Computed tomography is a good diagnostic method to measure the value of cortical thickness and bone mineral density simultaneously in mental and gonial region of the mandible in premenopausal female using low dose combined oral contraceptive pill which have small effect on bone ;depended on the woman's age and the duration of using the pill ;that did not appear until about two years of use.
Background: Genioglossus advancement is a surgical procedure to advance the tongue in some patients with obstructive sleep apnea syndrome.The important step in this procedure is that of accurately capturing the bone segment attached to the genioglossus muscle to avoid complications such as mandibular fracture, devitalization of the inferior incisor roots, and incomplete incorporation of the genioglossus Materials and Method: Computed tomography scans were taken for 53 Iraqi adult patients (28 male and 25 female) range from (18-35) years with skeletal class I classification and intact anterior mandible dentition included in this study using sagittal and axial sections. The measurements were done for genial tubercle and anterior mandibular re
... Show MoreThe present study aims at assessing the status of heavy metals such as nickel, cadmium and lead to pollute some areas of Baghdad city. In this study the spectral absorption device and the program ArcGIS 10.2 will using. The soil samples were taken from five different locations in Baghdad, including Ameriya, Kadhimiya, Palestine Street, Jadiriyah and Taji for the 5cm depth layer on both sides of the road. This work on soil samples has been completed in two :phases 1 - Preparation of samples: For the purpose of converting solid material into a extract containing elements in the form of single ions can be estimated by the device 2-Determination of elements: Samples prepared to the device
An effective two-body density operator for point nucleon system folded with two-body correlation functions, which take account of the effect of the strong short range repulsion and the strong tensor force in the nucleon-nucleon forces, is produced and used to derive an explicit form for ground state two-body charge density distributions (2BCDD's) and elastic electron scattering form factors F (q) for 19F, 27Al and 25Mg nuclei. It is found that the inclusion of the two-body short range correlations (SRC) has the feature of reducing the central part of the 2BCDD's significantly and increasing the tail part of them slightly, i.e. it tends to increase the probability of transferring the protons from the central region of the nucleus towards
... Show MoreThe ground charge density distributions (CDD), elastic charge form factors and proton, charge, neutron, and matter root mean square (rms) radii for stable 40Ca and 48Ca have been calculated using single-particle radial wave functions of Woods-Saxon (WS) and harmonic-oscillator (HO) potentials. Different central potential depths are used for each subshell which is adjusted so as to reproduce the experimental single-nucleon binding energies. An excellent agreement between the calculated rms charge radii and experimental data are found for both nuclei using WS and HO potentials. The calculated proton rms radii for 40Ca are found to be in good agreement with experiment data using both WS and HO potentials while the results for 48Ca showed an ov
... Show MoreAn effective two-body density operator for point nucleon system
folded with the tenser force correlations( TC's), is produced and used
to derive an explicit form for ground state two-body charge density
distributions (2BCDD's) applicable for 25Mg, 27Al and 29Si nuclei. It is
found that the inclusion of the two-body TC's has the feature of
increasing the central part of the 2BCDD's significantly and reducing
the tail part of them slightly, i.e. it tends to increase the probability of
transferring the protons from the surface of the nucleus towards its
centeral region and consequently makes the nucleus to be more rigid
than the case when there is no TC's and also leads to decrease the
1/ 2
r 2 of the nucleu
We propose a system to detect human faces in color images type BMP by using two methods RGB and YCbCr to determine which is the best one to be used, also determine the effect of applying Low pass filter, Contrast and Brightness on the image. In face detection we try to find the forehead from the binary image by scanning of the image that starts in the middle of the image then precedes by finding the continuous white pixel after continuous black pixel and the maximum width of the white pixel by scanning left and right vertically(sampled w) if the new width is half the previous one the scanning stops.
The purpose of present work is to study the relationship of the deformed shape of the nucleus with the radioactivity of nuclei for (Uranium-238 and Thorium-232) series. To achieve our purposes we have been calculated the quadruple deformation parameter (β2) and the eccentricity (e) and compare the radioactive series with the change of the and (e) as indicator for the changing in the nucleus shape with the radioactivity. To obtain the value of quadruple deformation parameter (β2), the adopted value of quadruple transition probability B (E2; 0+ → 2+) was calculated from Global Best fit equation. While the eccentricity (e) was calculated from the values of the minor and major ellipsoid axis’s (a & b). From the results, it is obvi
... Show MoreThree azo compounds were synthesized in two different methods, and characterized by FT-IR, HNMR andVis) spectra, melting points were determined. The inhibitory effects of prepared compounds on the activity of human serum cholinesterase have been studied in vitro. Different concentrations of study the type of inhibition. The results form line weaver-Burk plot indicated that the inhibitor type was noncompetitive with a range (33.12-78.99%).