Background: The marginal adaptation has a key role in the success and longevity of the fixed dental restoration, which is affected by the impression and the fabrication techniques .The objective of this in vitro study was to evaluate and compare the marginal fitness of lithium disilicate crowns using two different digital impression techniques (direct and indirect techniques) and two different fabrication techniques (CAD/CAM and Press techniques). Materials and Methods: Thirty two sound upper first premolar teeth of comparable size extracted for orthodontic reason were selected in this study .Standardized preparation of all teeth samples were carried out with modified dental surveyor to receive all ceramic crown restoration with 1 mm deep chamfer finishing line, 4 mm axial length and 6 degree convergence angle. Half of the teeth were duplicated and poured in type IV dental stone to have sixteen dies and then these dies and the remaining teeth divided in to two groups according to the type of digital impression techniques (n=16) as follow: Group A: Indirect digital impression technique scanned by inEos X5 camera; Group B: Direct digital impression technique scanned by CEREC AC Omnicam camera. Each group was subdivided according to the technique of fabrication into two subgroups (n=8): Press technique using IPS e-max press (A1, B1); CAD/CAM technique using IPS e-max CAD (A2, B2).Marginal gaps were evaluated on the prepared teeth at four defined points on each aspect using digital microscope at a magnification of (280X). One way ANOVA and LSD tests were used to identify and localize the source of difference among the groups. Results: The results showed that indirect digital impression with IPS e-max CAD/CAM group A2 revealed the poorest marginal integrity with (55.93 μm ± 3.300). Group B2 and group A1 were next in line with(44.49 μm ± 6.840 and 37.74 μm± 5.433) respectively, while in the first group of restorations, the result of 29.9 μm ± 5.534 obtained with direct digital impression with pressable ceramic was clearly better. Conclusions: All the tested digital impression techniques showed clinically acceptable accuracy and intraoral scanning with pressable ceramic significantly enhanced the marginal fit
The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B1 and fumonisin B2 by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C18 solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith® RP-18e column
... Show MoreLe présent travail aborde la question de l’enseignement de traduction en tant que matière faisant partie du programme élaboré dans des Départements de Français au sein de certaines universités irakiennes, en particulier celle de Bagdad. La méthode d’enseigner suivie constitue une véritable problématique qu’on a bien diagnostiquée à partir de quelques années d’expériences, à la lumière des observations faites dans des cours de traduction professionnelle, et dans la perspective des citations et témoignages établies par des traductologues et pédagogues et principalement par Marianne LEDERER qui a établi la Théorie Interprétative de la traduction. Mais pourquoi l’enseignement lui-même poserait une telle probl
... Show MoreThe sustainable environmental neighborhoods is sustainable development of neighborhoods that include considerations related to transport, density, urban forms, and environmental buildings and especially those related to social and functional integration, and civil society participation, This standard, which did not attract the attention of specialists in the 1990s, has today become a center of attention for all those interested in urbanism and sustainability. The problem of the research is the existence of urban problems in residential neighborhoods that lead to lack of sustainability in the city, and the research aims to explain the role and importance of environmental sustainability
Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness
... Show MoreIn this paper, a new equivalent lumped parameter model is proposed for describing the vibration of beams under the moving load effect. Also, an analytical formula for calculating such vibration for low-speed loads is presented. Furthermore, a MATLAB/Simulink model is introduced to give a simple and accurate solution that can be used to design beams subjected to any moving loads, i.e., loads of any magnitude and speed. In general, the proposed Simulink model can be used much easier than the alternative FEM software, which is usually used in designing such beams. The obtained results from the analytical formula and the proposed Simulink model were compared with those obtained from Ansys R19.0, and very good agreement has been shown. I
... Show MoreRheumatoid arthritis is a chronic, progressive, inflammatory autoimmune disease of unidentified etiology, associated with articular, extra-articular and systemic manifestation that require long-standing treatment. Taking patient’s beliefs about the prescribed medication in consideration had been shown to be an essential factor that affects adherence of the patient in whom having positive beliefs is an essential for better adherence. The purpose of the current study was to measure beliefs about medicines among a sample of Iraqi patients with Rheumatoid arthritis and to determine possible association between this belief and some patient-certain factors. This study is a cross-sectional study carried out on 250 already diagnosed rheumatoid
... Show MoreBackground: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness
... Show MoreLightweight concrete-filled tube (CFST) columns offer numerous benefits, such as reduced weight, enhanced resistance to buckling, improved structural performance, and the ability to endure cyclic loading. This study considered key research on the structural behavior of CFST columns, covering various topics, including lightweight concrete, methods of concrete placement within steel tubes, and CFST columns with and without shear connectors. The literature review reveals that while several researchers have explored the use of shear connectors as a load-transfer mechanism in CFST columns, there is no consensus on the design methodology for connector resistance. Shear connectors signifi
Retained soft tissue foreign bodies following injuries are frequently seen in the Emergency and Plastic Surgery practice. The patients with such presentations require a watchful and detailed clinical as- sessment to overcome the anticipant possibility of missing them. However, the diagnosis based on the clinical evaluation is usually challenging and needs to be supported by imaging modalities that are suboptimal and may fail in identifying some types of foreign bodies. Owing to that, serious complications such as chronic pain, infection, and delayed wound healing can be faced that necessitate a prompt intervention to halt those detrimental consequences. The classical method of removal is a surgical exploration which is not free of risks.
... Show More