Preferred Language
Articles
/
jbcd-2373
The Effect of Different Pouring Interval of Conventional Impression on the Marginal Accuracy of Full Contour Zirconia Crowns in Comparison with Digital Impression (An in vitro study)
...Show More Authors

Background: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown restoration with deep chamfer finishing line all around the tooth with (1mm) depth, axial length (4mm) and convergence angle (6 degree). The specimens separated into two groups; Group A; eight specimens were scanned digitally by using Omnicam scanner; Group B; conventional impressions were taken for the remaining thirty two specimens and further subdivided to four groups according to the time of impression pouring; Group B1: PVS were poured after 30 minutes; Group B2: PVS were poured after 24 hours; Group B3: PVS were poured after 7 days; Group B4:PVS were poured after 14 days. Marginal discrepancy was measured at four points at each tooth surface. Sixteen points per tooth were measured using digital microscope at (180X) magnification. One-way ANOVA test and LSD test were carried out to see if there was any significant difference among the means of the conventional impression groups. Independent samples t-test was carried out to examine if there is any significant difference between digital and conventional impression technique. Results: group B2 had the least mean of marginal gap with statistically significant difference when compared to group B1 and statistically highly significant difference when compared to group B3 and B4. There was a statistically highly significant difference in the vertical marginal gap between digital impression technique and conventional impression. Conclusions: the pouring of conventional impression after 24 hours provides better marginal fit than other pouring time. The digital impression provides better marginal fit than conventional impression.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Craniomaxillofacial Research & Innovation
Partial Bone Necrosis Following Sagittal Split Ramus Osteotomy: Report of a Complicated Orthognathic Jaw Surgery
...Show More Authors
Study Design

Case Report.

Objective

To present a case of a previous complicated mandibular orthognathic surgery that aimed to setback the mandible in a female cleft lip and palate (CLP) patient, which led to bone necrosis on one side with subsequent severe mandibular deviation and facial asymmetry. We additionally reviewed the previous reports of similar complications, the pathophysiology and the factors that could lead to this dreadful result.

Method

A 27-year-old female patient presented with a severe dentofacial deformity secondary to a complicated bilateral sagittal spli

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Nov 30 2014
Journal Name
International Journal Of Advanced Research In Science, Engineering And Technology
Structural Characteristics and photoconductivity of Cerium doped Zinc Sulfide Nanoparticles synthesized via coprecipitation method
...Show More Authors

ZnS:Ce3+ nanoparticles were prepared by a simple microwave irradiation method under mild condition. The starting materials for the synthesis of ZnS:Ce3+ quantum dots were zinc acetate (R & M Chemical) as zinc source, thioacetamide as a sulfur source, cerium chloride as cerium source and ethylene glycol as a solvent. All chemicals were analytical grade products and used without further purification. The quantum dots of ZnS:Ce3+ with cubic structure were characterized by X-ray powder diffraction (XRD), the morphology of the film is seen by scanning electron microscopy (SEM) also by field effect scanning electron microscopy (FESEM) and XRD. Upon exposure to 460 nm light at zero bias voltage, ZnS:Ce3+/p-Si showed a high sensitivity of 4000% an

... Show More
Publication Date
Mon Oct 01 2018
Journal Name
Data In Brief
Chemical and structural data of (1, 2, 3-triazol-4-yl) pyridine-containing coordination compounds
...Show More Authors

The data presented in this paper are related to the research article entitled “Novel dichloro(bis{2-[1-(4-methylphenyl)-1H-1,2,3-triazol-4-yl-κN3 ]pyridine-κN})metal(II) coordination compounds of seven transition metals (Mn, Fe, Co, Ni, Cu, Zn and Cd)” (Conradie et al., 2018) [1]. This paper presents characterization and structural data of the 2-(1-(4-methyl-phenyl)-1H-1,2,3-triazol-1-yl)pyridine ligand (L2 ) (Tawfiq et al., 2014) [2] as well as seven dichloro(bis{2- [1-(4-methylphenyl)-1H-1,2,3-triazol-4-yl-κN3 ]pyridine-κN})metal (II) coordination compounds, [M(L2 )2Cl2], all containing the same ligand but coordinated to different metal ions. The data illustrate the shift in IR, UV/VIS, and NMR (for diamagnetic complexes) peaks wh

... Show More
Preview PDF
Publication Date
Sun Dec 14 2014
Journal Name
Molecular Crystals And Liquid Crysta
Synthesis and Mesomorphic Behavior of Two New Homologous Series Containing Azobenzene and 1,3,4-Oxadiazole Units
...Show More Authors

Two new nonsymmetrical mesogenic homologous series of terminal substituent ether (series [Vn]) and carboxy (series [VIn]) incorporating azobenzene and 1,3,4-oxadiazole group were synthesized. Both series have been All compounds thus isolated were purified and characterized by elemental analysis, Fourier Transform Infrared Spectroscopy, 1H NMR, along with thermal analysis and texture observation using Differential Scanning Calorimetry (DSC) and Polarizing Optical Microscopy (POM), respectively. All compounds of the first series exhibited liquid crystalline properties. The homologues [V1]-[V3] display a nematic mesophase, the compounds [V4]-[V7] exhibit a dimorphism behavior, nematic (N) and smectic A (SmA) mesophases, the compounds [V8] and

... Show More
Publication Date
Sat Sep 05 2020
Journal Name
Al-kindy College Medical Journal
Morbidity and Mortality Pattern of Neonates Admitted to Neonatal Care Unit.Central Teaching Pediatric Hospital Baghdad
...Show More Authors

Background; Neonatal period is a very vulnerable period of life due to many problems, In spite of advances in perinatal and neonatal care still, the mortality rate of neonate high especially in developing country The World Health Organization estimates that globally four million neonatal deaths per year, Developing countries account for around 99% of the neonatal mortality in the world, In Iraq. Neonatal mortality rate about 19 per 1000 live births which represent 56% of child death below 5 years age in 2012. .
Objectives The aims of the study were to determine the institutional new-born case fatality rate and the cause of admission and death in the neonatal care unit.
Method; Across-section study was carried out of the Neonatal Ca

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Sep 02 2024
Journal Name
مجلة القادسية لللقانون والعلوم السياسية
Strategies of Israeli National Security towards Syrian Border Cities after 2011 (Quneitra, Swayda, and Daraa)
...Show More Authors

Although Israel's national security strategy, shaped by Ben Gurion in the 1950s, has remained steadfast, Israeli leaders have been keen to adapt and change some of its means and tools to maintain its national security. These changes were a response and adaptation to the complex and geostrategic transformations in the region since the end of the cold war. Traditional challenges to Israel's national security have declined as unconventional challenges have increased. This shift has adversely affected the efficiency and effectiveness of Israel's national security strategies. It has become necessary for Israel to confront regional actions taken by minor states and regional actors that have ensured the accumulation of its military capabilities. M

... Show More
View Publication
Publication Date
Tue Mar 30 2021
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Vanadium and Nickel Ions from Iraqi Atmospheric Residue by Using Solvent Extraction Method
...Show More Authors

Iraqi crude Atmospheric residual fraction supplied from al-Dura refinery was treated to remove metals contaminants by solvent extraction method, with various hydrocarbon solvents and concentrations. The extraction method using three different type solvent (n-hexane, n-heptane, and light naphtha) were found to be effective for removal of oil-soluble metals from heavy atmospheric residual fraction. Different solvents with using three different hydrocarbon solvents (n-hexane, n-heptane, and light naphtha) .different variables were studied solvent/oil ratios (4/1, 8/1, 10/1, 12/1, and 15/1), different intervals of perceptual (15, 30-60, 90 and 120 min) and different temperature (30, 45, 60 and 90 °C) were used. The metals removal percent we

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 05 2011
Journal Name
Baghdad Science Journal
Design and Construction of a Testing Platform and Estimating Attenuation Painting Reflectivity to Laser Beam
...Show More Authors

The project has been described the design and construction of a reliable optical testing platform used for evaluate the reflectivity of metal surfaces treated with special paintings required for laser beam attenuation. The platform comprises an Nd-YAG laser system which has been designed and fabricated with specifications to be compatible with their corresponding in laser range finder transmitters used for various applications. The reflectivity of various attenuating paintings, at different detection angles, has been observed. Moreover, the variation of the reflected energy with painting type and metal type to be painted has been studied experimentally. Results illustrated the existence of a definite angle, at which the reflectivity was max

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 01 2021
Journal Name
International Journal Of Geomate
NONLINEAR SIMULATION ANALYSIS OF TAPERED REINFORCED CONCRETE COLUMN (SOLID AND HOLLOW) BEHAVIOR UNDER AXIAL LOAD
...Show More Authors

View Publication
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Mar 17 2020
Journal Name
Optical And Quantum Electronics
Photocatalytic activity of Ag-doped TiO2 nanostructures synthesized by DC reactive magnetron co-sputtering technique
...Show More Authors

View Publication
Scopus (23)
Crossref (5)
Scopus Clarivate Crossref