Background: Tooth eruption is a localized process in the jaws which exhibits precise timing and bilateral symmetry. Develop within the jaws and their eruption is a complex infancy process during which they move through bone to their functional positions within the oral cavity. For species with more than one set of teeth, eruption of the second set also accomplishes. The key to the successful clinical management of tooth eruption consists of understanding that this process consists largely of the local regulation of alveolar bone metabolism to produce bone resorption in the direction of eruption and shift and formation of bone at the opposite side.The amniotic sac contains a considerable quantity of stem cells. These amniotic stem cells are able to differentiate into various tissues, which used in many field. Vascular endothelial growth factor (VEGF) is an important angiogenic factor reported to induce migration and proliferation of endothelial cells, enhance vascular permeability, and modulate thrombogenicity. VEGF expression in cultured cells (smooth muscle cells, macrophages, endothelial cells) is controlled by growth factors and cytokines. The aim of this study was to study the administration of cell molecules of (Chorion, Amnion and Amniotic fluid) around developing mouse tooth and studying the expression of VEGF marker. Materials and Methods: forty eight albino Swiss mice of one day old age injected with isolated amniotic stem cells in the anterior region of maxilla (incisors area) other 16 mice injected with saline represents control. Sacrifice 4 mice for each period (4, 7, 10, and 13) day old age. The result were studied histologically and immunohistochemistry. Results: VEGF marker localized and identified in 3 areas; pulp, P.D.L, and Bone. In pulp. The mean value of positive VEGF expression showed to be highest in Amnion group in comparison to the other studied groups. The marginal mean value of all periods reported to be highest in Amnion groups followed by Chorion group. The period 10 day showed highest marginal means value for positive VEGF expression for all groups. In P.D.L. area Amniotic fluid records the highest mean and marginal mean value specifically at day-10 in comparison to other studied groups. In Bone area Amniotic fluid records the highest mean and marginal mean value among the studied groups followed by Chorion group. Period 7-day and 10-day shows high mean value for VEGF expression. Coincidence test for VEGF marker illustrates to be affected by Amniotic fluid application in P.D.L. and in bone area while Amnion and Chorion application showed to be concerned with pulp. Conclusion. It reported that amniotic fluid application affected on expression of VEGF in P.D.L and bone while amnion and chorion showed to affect on expression of VEGF in pulp.The present study highlighted on clinical and researcher application of Amniotic fluid and Chorion for supplement of stem cell in dental tissue engineering or even in other body tissues.
The present study aimed to investigate the anatomy, histology, and immunohistochemistry of parathyroid gland in two Iraqi mammals (Weasel, Herpestes javanicus and Long-ear hedgehog, Hemiechinus auritus) as a comparative study. A total of (20) animal for each species were used in the present study. Animals collected were immediately anesthesia and dissected to get the parathyroid gland. Methods of Humason and Bancroft and Stevens were employed for histological techniques. Different stains were used (Hematoxylin- Eosin stain-(H & E), Periodic Acid Schiff stain-(PAS), Azan stain, and Methyl Blue stain-(MB)) for staining the histological sections. Anti-calcitonin, code140778 marker used for immune-histochemical study. Results of the present stu
... Show MoreBackground: This study aimed to evaluate the effect of zirconia different surface treatments (primer, sandblast with 50μmAl2O3, Er,Cr:YSGG laser) on shear bond strength between zirconia surface and resin cement. Material and methods: Sixty presintered Y-TZP zirconia cylinder specimens (IPS e.max ZirCAD, Ivoclar vivadent) will be fabricated and sintered in high temperature furnace of (1500 C for 8 hours) according to manufacturer’s instructions to the selected size and shape of (5mm. in diameter and 6mm in height). All specimens were ground flat using 600.800.1000.1200, aluminum oxide abrasive paper to obtain a standardized surface roughness. Surface roughness values were then recorded in µm using surface roughness tester (profi
... Show MoreAbstract: An unfavorable complication of root canal is vertical root fracture. The aim of present study is to evaluate the vertical root fracture of treated teeth filled with gutta percha and Resilon obturating material using different sealers. Forty mandibular premolars used in the study. Canals randomly divided into four groups (n=10). Group-A eugenol-based (Endofill) sealer with gutta percha; GroupB epoxy-amine (AH Plus) sealer with gutta percha; Group-C resin-based (Real Seal) sealer with Resilon; or Group-D epoxide-based (Perma Evolution) sealer with gutta percha. Roots mounted vertically in cold cure acrylic blocks and subjected to vertical loading with a crosshead speed of 1mm ̸min. The point at which fracture of the roots occurred
... Show MoreHeat transfer around a flat plate fin integrated with piezoelectric actuator used as oscillated fin in laminar flow has been studied experimentally utilizing thermal image camera. This study is performed
for fixed and oscillated single and triple fins. Different substrate-fin models have been tested, using fins of (35mm and 50mm) height, two sets of triple fins of (3mm and 6mm) spacing and three frequencies
applied to piezoelectric actuator (5, 30 and 50HZ). All tests are carried out for (0.5 m/s and 3m/s) in subsonic open type wind tunnel to evaluate temperature distribution, local and average Nusselt number (Nu) along the fin. It is observed, that the heat transfer enhancement with oscillation is significant compared to without o
This work evaluates the influence of combining twisted fins in a triple-tube heat exchanger utilised for latent heat thermal energy storage (LHTES) in three-dimensional numerical simulation and comparing the outcome with the cases of the straight fins and no fins. The phase change material (PCM) is in the annulus between the inner and the outer tube, these tubes include a cold fluid that flows in the counter current path, to solidify the PCM and release the heat storage energy. The performance of the unit was assessed based on the liquid fraction and temperature profiles as well as solidification and the energy storage rate. This study aims to find suitable and efficient fins number and the optimum values of the Re and the inlet tem
... Show More