Background: Synthetic hydroxyapatite,(Ca10(PO4)6(OH2) can directly bond to bones without infection and fibrous encapsulation, thus is regarded as bioactive and biocompatible. The aim of the study was the estimation of microarchitecture bone parameters include bone mass (gm/cm2) cortical bone width (mm), thread width (mm), marrow space star volume analysis (V*m) and osteoblast, osteocyte cell number. Materials and methods: Ninety-six (96) commercially pure titanium CpTi) used in this study, (48) implants were coated with HA by dipping coating and (48) implants were used as control. They were inserted in (32) Newzland white rabbits and followed for 2 & 6 weeks. Mechanical torque removal test and histomorphometric analysis of bone microarchiteture were performed for evaluation of osseointegration. Results: Results revealed, Torque values were increased with advancing time for coated and uncoated groups. And specifically dip coated implant showed high value in comparison to control. Histomorphometric analysis for bone parameters showed highly significant difference in overall contrasted groups of implant in 2nd and 6th week interval. Conclusion: Dip coating method is an alternative coating technique for dental implant to enhance better bone implant contact and improve osseointegration.
Zinc Oxide thin film of 2 μm thickness has been grown on glass substrate by pulsed laser deposition technique at substrate temperature of 500 oC under the vacuum pressure of 8×10-2 mbar. The optical properties concerning the absorption, and transmission spectra were studied for the prepared thin film. From the transmission spectra, the optical gap and linear refractive index of the ZnO thin film was determined. The structure of the ZnO thin film was tested with X-Ray diffraction and it was formed to be a polycrystalline with many peaks.
Background: Bone cutter is widely used in the
Middle east area to cut the prepuce during circumcision.
Results :One hundred twenty one male neonates
were included in this study.The mean operative
time (MOT) was 6 minutes, mean time of
healing (MTH) was 5 days, 7 cases (5.9%)
developed early & late complications, 2 (1.7%)
had bleeding, 3 (2.5%) developed infection, 2
(1.7%) developed late complications in the form
of meatal stenosis.
Settings:Al-Yarmouk Teaching Hospital and a
private surgical clinic.
Aim of the study: To assess the safety of
circumcision using bone cutter.
Methods: Over 6 years period from Jan. 2000
till Dec. 2005, one hundred twenty one male
neonates were circumci
Consumption of different types of beverages and liquid drugs can affect of the surface properties of restorative material. This may lead to an increased probability of dental caries and periodontal inflammation.
This study evaluated and compared the effect of amoxicillin suspension (AMS) and azithromycin suspension (AZS) on the surface roughness (SR) of silver-reinforced gl
Background:Open reduction and internal fixation (ORIF) of using miniplates and screws is the treatment of choice of mandibular fractures. It is important to know both: the region where the bone providesafirm anchorage, andthe topography of the dental apices and inferior alveolar nerve to avoiddamaging them when inserting the screw. The aim of this study is to determine the thickness of buccal cortical plate and that of buccal bone at the parasymphysis and mandibular body, thereby determining the area that provide afirm anchorage and the maximum length of mono-cortical screws that can be safely placed in these regions without injuring the tooth roots or mandibular nerve. Materials and Methods:The sample of the present study was 110 Iraqi sub
... Show MoreBackground: Molars and premolars are considered as the most vulnerable teeth of caries attack, which is related to the morphology of their occlusal surfaces along with the difficulty of plaque removal. different methods were used for early caries detection that provide sensitive, accurate preoperative diagnosis of caries depths to establish adequate preventive measures and avoid premature tooth treatment by restoration. The aim of the present study was to evaluate the clinical sensitivity and specificity rates of DIAGNOdent and visual inspection as opposed to the ICDAS for the detection of initial occlusal caries in noncavitated first permanent molars. Materials and Methods: This study examined 139 occlusal surface of the first permanent
... Show Morehe current research aims at showing the correlation and effect of the internal environment analysis in the quality of health service in AL_Elwiya Maternity Teaching Hospital, researcher depended on the integral method in the "analytical descriptive method" for the study of the relation between the main variables and the sub-variables throughout data collection required by the theme of this study, a case study" in tackling the data and information related to the financial aspects of the internal environment.
The problem of the study was manifested in the essential question, that is (is there internal struc
... Show MoreBackground: Controversy exists concerning the presence and amount of the Bennett mandibular immediate side shift among patients and whether it is necessary to accommodate for it in adjustable articulators. The aim of this study was to register and calculate the amount of any immediate side shift (ISS) present in patients requiring full mouth rehabilitation. Materials and methods: 3- dimensional condylar movements of 50 Iraqi TMD-free patients were recorded using a stereographic fully adjustable articulator system during protrusion, left and right eccentric mandibular movements. Protrusive angles of each patient were verified to figure out the suitable fossa analog for each case. The thickness of each right and left premade fossa analog sele
... Show MoreAn experimental study was carried out for an evaporative cooling system in order to investigate the effect of using an aluminum pad coated with fabric polyester. In the present work, it was considered to use a new different type of cooling medium and test its performance during the change in the wet-bulb temperature and dry-bulb temperature of the supply air outside of the pad, the relative humidity of the supply air, the amount of air supplied (300-600) CFM and also the change of the amount of circulated water (1.75, 2.5, 4.5) liter per minute. A decrease in the WBT of the air was obtained, whereas the WBT of the air entering the pad was 26.5 . In contrast, the WBT of the outside air had reached 23 even though eva
... Show MoreIn this study, experimental and numerical applied of heat distribution due to pulsed Nd: YAG laser surface melting. Experimental side was consists of laser parameters are, pulse duration1.3