Preferred Language
Articles
/
jbcd-2222
The Effect of Artificial Saliva on The Surface Roughness of Different Esthetic Archwires (An in Vitro Study)
...Show More Authors

Background:The demand for esthetic orthodontic appliances is increasing so that the esthetic orthodontic archwires were introduced. This in vitro study was designed to evaluate the surface roughness offiber-reinforced polymer composite (FRPC) archwires compared to coated nickel-titanium (NiTi) archwires immersed in artificial saliva. Materials and Methods:Three types of esthetic orthodontic archwires were used: FRPC (Dentaurum), Teflon coated NiTi (Dentaurum) and epoxy coated NiTi (Orthotechnology). They were round (0.018 inch) in cross section and cut into pieces of 15 mm in length.Forty pieces from each type were divided into four groups; one group was left at a dry condition and the other three groups were immersed in artificial saliva (pH=6.75 ± 0.015) at 37ºC for 1, 14 and 28 days intervals. The AFM was used to evaluatesurface analysis of all samples.ANOVA, Kruskal-Wallis, LSD and Mann-Whitney U tests were used to identify and localize the source of differences among the groups. Results:At each immersion period, FRPC wires exhibited the highest Ra among the study groups, except at 28 days immersion period where the Teflon coatings were the roughest. On the other hand, the least rough surfaces were the epoxy coatings when compared to analogous esthetic archwires, except at 1 day immersion period where the Teflon coatings had the least roughness. However, statistically non-significant differences were found between Teflon and epoxy at the dry condition and the 1 day immersion. Conclusions:The epoxy coated archwires are the best and the most appropriate esthetic orthodontic alignment archwires in term of the least surface roughness initially and over the course of study period.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 21 2018
Journal Name
Al-kindy College Medical Journal
Evaluation of the clinical examination in thediagnosis of acute medial collateral ligament injury of the knee joint in comparism with examination under general anesthesia
...Show More Authors

Background: Tear of MCL of the knee is a frequent problem among knee ligaments injuries.Injuries to the MCL are usually caused by contact on the outside of the knee and are accompanied by sharp pain on the inside of the knee. Contrary to most other knee ligaments the medial collateral ligament (MCL) has an excellent ability to heal, being fairly large and well vascularised structure. The vast majority of isolated medial ligament injuries heal without significant long-term problems

Objectives: is to compare between the early clinical examination, and assessment under general anesthesia (GA), and to find out the best methods to assess the MCL tear especially in suspected cases.

Type

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 11 2023
Journal Name
Journal Of Educational And Psychological Researches
Content Assessment of the Sciences Textbooks of Grades (1-4) in the Light of International Standards in Mathematics and Science TIMSS 2019 (Content Dimension)
...Show More Authors

The current research aims to determine the requirements of Trends of International Mathematics and Science Study (TIMSS 2019) and to find out the extent to which the content of science textbooks for grades (1-4) in the Sultanate of Oman includes the requirements of (TIMSS 2019). Only the content dimension has been taken into account when conducting the content analysis. The study population includes all science books from the first to the fourth grade for the academic year 2021-2022. The study identified and organized the requirements in the study tool, which is a list of requirements of (TIMSS 2019). The results showed a general deficiency in all grades (1-4) in the content dimension including many main topics, subtopics, and objectives

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
FEM: Mono-implant cement retained crown with two different adhesive materials
...Show More Authors

Background: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Wed Dec 30 2020
Journal Name
Journal Of Planner And Development
Balanced Urban Development, A Strategy To Address Tension Between Different Contexts
...Show More Authors

In their growth stages, cities become an aggregation of different urban contexts as a result of development or investment projects with other goals, which creates urban tension at several levels. Previous studies presented different approaches and methods to address specific aspects of urban stress, and thus contemporary visions and propositions varied, which required a field for research. The research, from a review of the proposals, the research problem emerged in need to study the indicators and trends of balanced urban development that address the tensions between different social, economic and urban contexts". Accordingly, the objective of the research is determined as "Building a comprehe

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
International Journal Of Research In Social Sciences & Humanities. E-issn
CONCEPTS OF LITERATURE: COMPARATIVE LITERATURE BY HENRY GIFFORD (an Article REVIEW).
...Show More Authors

BOOK REVIEW

Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Pharmacy Research
Preparation and characterization of lacidipine as an oral fast dissolving film
...Show More Authors

Background: Fast dissolving oral drug delivery system is solid dosage form which disintegrates or dissolves within second when placed in the mouth without need of water or chewing. In present investigation, an attempt has been made to develop oral fast dissolving film of calcium channel blocker lacidipine. Method: Five formulas were prepared by solvent casting method using HPMC (METOLOSE)® as a film forming polymer and evaluated for their physical characteristics such as thickness, weight variation, folding endurance, drug content, disintegration time and in vitro drug release. The compatibility of the drug in the formulation was confirmed by FTIR and DSC studies. Result and Conclusion: The optimized formula F1 showed minimum in vitr

... Show More
Scopus (2)
Scopus
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Characterization of nickel oxide nanocatalyst electrodes for an alkaline fuel cell
...Show More Authors
Abstract<p>In this paper had been studied the characterization of the nanocatalyst (NiO) Mesh electrodes. For fuel cell. The catalyst is prepared and also the electrodes The structural were studied through the analysis of X-ray diffraction of the prepared nanocatalyst for determining the yielding phase and atomic force microscope to identify the roughness of prepared catalyst surface, Use has been nanocatalyst led to optimization of cell voltage, current densities & power for a fuel cell.</p>
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue Dec 26 2017
Journal Name
Al-khwarizmi Engineering Journal
Simulation Recording of an ECG, PCG, and PPG for Feature Extractions
...Show More Authors

Recently, the development of the field of biomedical engineering has led to a renewed interest in detection of several events. In this paper a new approach used to detect specific parameter and relations between three biomedical signals that used in clinical diagnosis. These include the phonocardiography (PCG), electrocardiography (ECG) and photoplethysmography (PPG) or sometimes it called the carotid pulse related to the position of electrode.

Comparisons between three cases (two normal cases and one abnormal case) are used to indicate the delay that may occurred due to the deficiency of the cardiac muscle or valve in an abnormal case.

The results shown that S1 and S2, first and second sound of the

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2023
Journal Name
Al-academy
Aesthetics Contents of Data Visualization as an Input to its humanization
...Show More Authors

The aesthetic contents of data visualization is one of the contemporary areas through which data scientists and designers have been able to link data to humans, and even after reaching successful attempts to model data visualization, it wasn't clear how that reveals how it contributed to choosing the aesthetic content as an input to humanize these models, so the goal of the current research is to use The analytical descriptive approach aims to identify the aesthetic contents in data visualization, which the researchers interpreted through pragmatic philosophy and Kantian philosophy, and analyze a sample of data visualization models to reveal the aesthetic entrances in them to explain how to humanize them. The two researchers reached seve

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Spot Welding of Dissimilar Metals Using an Automated Nd:YAG Laser System
...Show More Authors

An assembled pulsed Nd:YAG laser-robot system for spot welding similar and dissimilar metals is presented in this paper. The study evaluates the performance of this system through investigating the possibility and accuracy of executing laser spot welding of 0.2 mm in thickness stainless steel grade AISI302 to 0.5 mm in thickness low carbon steel grade AISI1008. The influence of laser beam parameters (peak power, pulse energy, pulse duration, repetition rate, and focal plane position on the final gained best results are evaluated. Enhancement of the experimental results was carried by a computational simulation using ANSYS FLUENT 6.3 package code.

View Publication Preview PDF