Preferred Language
Articles
/
jbcd-2221
Color Stability of Different Aesthetic Archwires after Immersion into Different Types of Mouthwashes(An In Vitro Study)
...Show More Authors

Background: Because of the demands for aesthetic orthodontic appliances have increased, aesthetic archwires have been widely used to meet patient's aesthetic needs. The color stability of aesthetic archwires is clinically important, any staining or discoloration will affect patient’s acceptance and satisfaction. This study was designed to evaluate the color stability of different types of aesthetic archwires after immersion into different types of mouth washes. Materials and methods: Four brands of nickel titanium coated aesthetic arch wires: Epoxy coated (Orthotechnology and G&H) and Teflon coated (Dany and Hubit) were evaluated after 1 week, 3 weeks and 6 weeks of immersion into two types of mouthwashes (Listerine with alcohol and Listerine without alcohol). Color change measurements were performed by using spectrophotometer VITA Easyshade Compact according to the commission Internationale de I’Eclairage L*a*b* color space system. Results: The results of this study showed that there were highly significant differences in color change values among all brands of aesthetic archwires at various immersion media. On the other hand, a significant difference was found between Dany and Orthotechnology aesthetic archwires at 1 week immersion in distilled water. Listerine with alcohol mouthwash produced more color changes of aesthetic archwires and color change value increases with the time of immersion. Conclusions: All brands of aesthetic archwires showed different degrees of color changes but most of these changes were not visible or clinically acceptable.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Feb 15 2025
Journal Name
Iraqi Journal Of Science
Effect of Aluminum Dust Particles on Plasma Parameters at Different Gas Pressure with Different Dust Contents
...Show More Authors

In this work, the effect of aluminum (Al) dust particles on the DC discharge plasma properties in argon was investigated. A magnetron is placed behind the cathode at different pressures and with varying amounts of Al. The plasma temperature (Te) and density (ne) were calculated using the Boltzmann equation and Stark broadening phenomena, which are considered the most important plasma variables through which the other plasma parameters were calculated. The measurements showed that the emission intensity decreases with increasing pressure from 0.06 to 0.4 Torr, and it slightly decreases with the addition of the NPs. The calculations showed that the ne increased and Te decreased with pressure. Both Te and ne were reduced by increasing

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
Study of Stability of Personal Dosimeter
...Show More Authors

The study is carried out by using personal dosimeters (film badge). The films are irradiated to absorbed dose of range (0.01-10000 rad). The calibration curves are drawn by using the ordinary method taking into account the filtration effects in three regions (D (Pb/Sn),D(Du),D(300). The calibration films are stored in ambient condition. It is found that the optical density increases, which is attributed to the photodegradation of the films may induce localized states in the energy gap causing increasing in optical absorption, but optical density decreases, which attributed to the photodegradation of the films may cause some cracks at the film surface during the first month, whereas at the rest months we see clear stability in optical d

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Advances In Bioresearch
Survey of Species Insects Indoor in Different Localities of Iraq
...Show More Authors

Publication Date
Wed Jun 01 2022
Journal Name
Journal Of Nursing Education
Compassion Competence Among Nursing Students From Different Cultures: A Multinational Study
...Show More Authors
Background:

Compassion competence is a nurse's ability to provide patient-centered care and communicate with patients in a sensitive and insightful manner. This descriptive cross-sectional survey study aimed to assess the compassion competence of a multinational group of nursing students.

Method:

A total of 1,158 undergraduate nursing students participated in this study, and stratified random sampling method was used to select participants from the 100 study level to the 400 or 500 level. Data were collected using the Compassion Competence Scale.

<
... Show More
View Publication
Scopus (14)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Wed Jun 10 2026
Journal Name
Journal Of Baghdad College Of Dentistry
An evaluation of canal transportation and centering ability at different levels of root canals prepared by self-adjusting file using computed tomography (A comparative study)
...Show More Authors

Background: The new concepts and technologies continue to change the dynamics of endodontic practices in the world. Rapid and significant changes in techniques, instrument design, and the type of metals used to manufacture endodontic instruments which have been made during the last few years in an attempt to overcome canal preparation errors. The purpose of this study is to measure and compare canal transportation and centering ability of Self Adjusting File with two rotary nickel-titanium (Ni-Ti) systems, ProTaper and BioRaCe at different levels. Material and Methods: Forty five distal roots of mandibular first molars with moderate curvature were selected using Schneider method. Roots were divided randomly into 3 groups of 15 each and were

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The reliability of insertion torque as an indicator for primary stability in immediate dental implant: A prospective clinical study
...Show More Authors

Background: The primary stability of the dental implant is a crucial factor determining the ability to initiate temporary implant-supported prosthesis and for subsequent successful osseointegration, especially in the maxillary non-molar sites. This study assessed the reliability of the insertion torque of dental implants by relating it to the implant stability quotient values measured by the Osstell device. Material and methods: This study included healthy, non-smoker patients with no history of diabetes or other metabolic, or debilitating diseases that may affect bone healing, having non-restorable fractured teeth and retained roots in the maxillary non-molar sites. Primary dental implant stability was evaluated using a torque ratc

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (5)
Scopus Crossref
Publication Date
Wed Jun 10 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of plasma treatment on shear bond strength of soft denture liner with two different types of denture base material (heat cure and light cure)
...Show More Authors

Background: In this study we evaluate the effect of plasma treatment (oxygen and argon) gas in two different exposure times on the surface of heat cure and light cure acrylic resin. Materials and method: 100 specimens of heat cure and light cure acrylic resin were fabricated. The measurements of the samples were (75mm, 25mm and 4.5mm) length, width and depth respectively with stopper of 3mm depth. Two types of gas used oxygen and argon in (5,10) min by using (DC-glow discharge plasma device) then we apply cold cure soft lining material, with the help of Instron machine we test the shear stress value. Results: A highly significant effect after argon and oxygen gases treatment in both 5 and 10 min exposure times on shear bond strength to soft

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 19 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Study of Two Types Finite Graphs in KU-Semigroups
...Show More Authors

In this ˑwork, we present theˑ notion of the ˑgraph for a KU-semigroup as theˑundirected simple graphˑ with the vertices are the elementsˑ of and weˑˑstudy the ˑgraph ofˑ equivalence classesˑofˑ which is determinedˑ by theˑ definition equivalenceˑ relation ofˑ these verticesˑ, andˑ then some related ˑproperties areˑ given. Several examples are presented and some theorems are proved. Byˑ usingˑ the definitionˑ ofˑ isomorphicˑ graph, ˑwe showˑ thatˑ the graphˑ of equivalence ˑclasses ˑand the ˑgraphˑof ˑa KU-semigroup ˑ areˑ theˑ sameˑ, in special cases.

Publication Date
Mon Aug 01 2022
Journal Name
Baghdad Science Journal
The Patterns of Poisoning Exposure in Different Ages in Duhok Governate: A three Years Study (2016, 2017, 2018)
...Show More Authors

Poisoning with toxic substances accidently or deliberately can be life threatening and especially in some countries that lack the essential tests and facilities to identify the types and causes of these toxic substances. In Iraq, as many other countries, poisoning is one of the chronic public health problems. However, very little literature about the pattern of poisoning cases, types and age is available in Duhok Governorate. Therefore, this study was conducted to determine the most common patterns of poisoning and the related age and gender in Duhok Governorate from 2016-2018, which would possibly contribute to the early diagnosis and treatment of poisoning. The present study was conducted for three years, started from 1st of

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Comparison of Fatigue Life Behavior between Two Different Composite Materials Subjected to Shot Peening at Different Times
...Show More Authors

This paper investigated the fatigue life behavior of two composite materials subjected to different times of shot peening (2, 4 and 6 min).The first material prepared from unsaturated polyester with E-glass reinforcement by 33% volume fraction. While, the second one was prepared from unsaturated polyester with aluminum powder by2.5% volume fraction. The experimental results showed that the improvement in endurance limit was obtained (for the first material) at 2, 4 and 6 min shot peening times where the percentage of maximum improvement was 25% at shot peening time of 6 min. While, the endurance limit of the second material decreased at shot peening times of 2, 4 and 6 min where the percentage of maximum reduction was 29 % at shot peenin

... Show More
View Publication Preview PDF