Background: The integration of modern computer-aided design and manufacturing technologies in diagnosis, treatment planning, and appliance construction is changing the way in which orthodontic treatment is provided to patients. The aim of this study is to assess the validity of digital and rapid prototyped orthodontic study models as compared to their original stone models. Materials and methods: The sample of the study consisted of 30 study models with well-aligned, Angle Class I malocclusion. The models were digitized with desktop scanner to create digital models. Digital files were then converted to plastic physical casts using prototyping machine, which utilizes the fused deposition modeling technology. Polylactic acid polymer was chosen as the printing material. Twenty four linear measurements were taken from digital and prototyped models and were compared to their original stone models “the gold standardâ€, utilizing the paired sample t-test and Bland-Altman plots. Results: Eighteen of the twenty four variables showed non-significant differences when digital models were compared to stone models. The levels of agreement between the two methods showed that all differences were within the clinically accepted limits. For prototyped models, more than half of the variables differed in non-significant amount. The levels of agreement were also within the clinically accepted limits. Conclusion: Digital orthodontic study models are accurate in measuring the selected variables and they have the potential to replace conventional stone models. The selected rapid prototyping technique proved to be accurate in term of diagnosis and might be suitable for some appliance construction.
The technical development has significant effects on the mediator Alcinmatugrave, and TV originated mainly based on technical, with the development and the continuation of these technologies and the enormous impact on the level of the television picture, initially dramas in recent times approaching in the aesthetic composition of the film thanks to the employment of modern digital technologies, Montag was not only one of the cinematic elements that went into television thanks to technical developments analogue and digital, and which added the possibility of large processors in the picture, high-definition digital cameras that have led to dispense often for artificial lighting intensive imaging light available, as these cameras have helpe
... Show MoreThe revolution of technology in the 21st century has changed radically the
climate of opinion concerning second language education. In order to excel in
today’s world, teachers and learners need to adopt new roles and be equipped with
new skills and competencies that go beyond the basic ones of listening, speaking,
reading, and writing; skills that cannot be gained if teachers teach mere academic
subjects, and students are evaluated on how well they have learnt the minute sub
skills in those content areas.
This session will touch upon several skills which may be considered the
new basics of the 21st century. Among these skills are: autonomy, active learning,
critical thinking, cooperative learning, and digita
The research tagged (Digital Collage in Contemporary Art) consisted of four chapters. The first chapter was devoted to the methodological framework of the research. The problem ended with the following questions: How does digital collage represent contemporary art? What is the variable at the level of meaning shifts in composing works according to the digital collage? Was the digital collage a qualitative leap in the path of the aesthetic pattern in art? How does digital collage interfere with contemporary life and societies? It included the aim of the research and its importance, while the second chapter dealt with two topics, the first (reading in the concept of collage), and the second (digital collage). The third chapter was devoted
... Show MoreAdvanced strategies for production forecasting, operational optimization, and decision-making enhancement have been employed through reservoir management and machine learning (ML) techniques. A hybrid model is established to predict future gas output in a gas reservoir through historical production data, including reservoir pressure, cumulative gas production, and cumulative water production for 67 months. The procedure starts with data preprocessing and applies seasonal exponential smoothing (SES) to capture seasonality and trends in production data, while an Artificial Neural Network (ANN) captures complicated spatiotemporal connections. The history replication in the models is quantified for accuracy through metric keys such as m
... Show MoreBackground: The purpose of the current study was to evaluate the efficacy of a new orthodontic bonding system (Beauty Ortho Bond) involving the shear bond strength in dry and wet environments, and adhesion remnant index (ARI) scores evaluation in regard to other bonding systems (Heliosit and Resilience Orthodontic Adhesives). Materials and methods: Sixty defect free extracted premolars were randomly divided into six groups of 10 teeth each, mounted in acrylic resin, three groups for a dry environment and three for a wet one. Shear bond strength test was performed with a cross head speed of 0.5 mm/min, while surfaces of enamel and bracket-adhesive-enamel surfaces were examined with stereomicroscope For ARI scores evaluation. Data were analyz
... Show MoreBackground: The therapeutic goal of orthodontic treatment is to establish ideal occlusion which includes both static and functional aspects. The objective of this study was to clarify functional occlusal treatment goals by analyzing functional occlusion in subjects with established normal occlusion and identify the differences between canine protected occlusion and group function occlusion. Materials and Methods: The sample consisted of 62 subjects with normal occlusion and with an age range of (18-25 years).Functional occlusal contacts during lateral excursion were identified on a fully adjustable articulator, and then the samples were classified according to: 1) Type of functional occlusion: A) Canine protected occlusion group (canine pr
... Show MoreOrthodontic treatment has two major problems: being lengthy and costly procedure. The present study was designed to evaluate the clinical efficacy of locally injected vitamin D3 Keywords: Orthodontic, Calcitriol, Local injection, OTM (calcitriol) in accelerating orthodontic teeth movement (OTM) and reducing treatment time and cost in humans. The study was performed on 15 Iraqi adult orthodontic patients within the age range 17-28 years, they are randomly allocated into three groups, each of five patients and treated with either 15 pg, 25 pg, or 40 pg/0.2ml calcitriol diluted with 10% dimethylsulfoxide (DMSO). The maxillary arch of every patient was divided into control (right) and experimental (left) sides. In addition to force application,
... Show MoreBackground: Although the new treatment methods developed in recent years are aiming to minimize the need for cooperation of the patients; however, the latter still important factor the treatment. The aim of the study was to evaluate the cooperation level of Class III maloc-clusion patients with orthodontic treatment. Materials and methods: This study followed a cross-sectional style; the targeted population was patients with Class III malocclusion who were treated with three different types of orthopaedic appliances. Four questionnaires were delivered to the patient, patient’s parents, and orthodontists. Statistical analyses of the study were performed with SPSS 20.0 software. Descriptive analyses were presented using fre-quency, percenta
... Show MoreStatement of the Problem. The use of orthodontic fixed appliances may adversely affect oral health leading to demineralizing lesions and the development of gingival problems. Aims of the Study. The study aimed to coat orthodontic archwires with chlorhexidine hexametaphosphate nanoparticles (CHX-HMP NPs) and to evaluate the elusion of CHX from CHX-HMP NPs. Materials and Methods. A solution of CHX-HMP nanoparticles with an overall concentration of 5 mM for both CHX and HMP was prepared, characterized (using atomic force microscope and Fourier transformation infrared spectroscopy), and used to coat orthodontic stainless steel (SSW) and NiTi archwires (NiTiW). The coated segments were characterized (using scanning electron microscopy
... Show MoreBackground: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chl
... Show More