Preferred Language
Articles
/
jbcd-2217
The Effect of Enamel Protective Agent on Shear and Tensile Bond Strength of Stainless Steel Brackets by Using Different Adhesive Agents (In Vitro Study)
...Show More Authors

Background: Decalcification of surface enamel adjacent to fixed orthodontic appliances, in the form of white spot lesions, is a wide spread and familiar well-known side effect of orthodontic treatment. The present study was carried out to evaluate the effect of enamel protective agent (Clinpro white varnish) on shear and tensile bond strength of Dentaurum orthodontic stainless steel brackets by using 3M Unitek and Ormco as orthodontic adhesive agents. Materials and methods: Sixty-four extracted human upper first premolar teeth were selected and randomly divided into two groups with 32 teeth each, representing the shear and tensile bond strength testing groups. Then according to the type of bonding adhesive and the addition of Clinpro before bonding (3M, Clinpro + 3M, Ormco, Clinpro + Ormco) each group was subdivided into four equal subgroups each with 8 teeth. After passing twenty-four hours of bonding procedure, where the samples were kept at 37˚C the brackets were debonded by using Tinius-Olsen universal testing machine to record the shear and tensile bond strength value. The difference in bond strength was analyzed by using ANOVA test at p≤0.05. Results: The use of Clinpro with 3M Unitek orthodontic bonding agent shows higher shear and tensile bond strength than Clinpro with Ormco orthodontic bonding agent. Conclusions: Using Clinpro white varnish before bonding can be successfully used with 3M Unitek orthodontic bonding agent.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
The effect of surlactin produced by Lactobacillus acidophilus on eye infectious bacteria in rabbits
...Show More Authors

Twenty five vaginal swabs from outpatients' healthy women were collected from Kamal Al-Samarai Hospital, Baghdad, to isolate and identify of Lactobacillus acidophilus. Three isolates were diagnosed as L. acidophilus which represents 15% of the total number of lactic acid bacterial (LAB) isolates; other LAB types represent 65% (20 isolates).The ability of L. acidophilus to produce surlactin was detected after measuring its biological activity to inhibit the adhesion of biofilm formed by Pseudomonas aeruginosa to surfaces using test tube method. It was found that all isolates were able to produce surlactin but the activity of surlactin was varying in each isolate. Surlactin produced by isolates 1 and 13 was the most effective. Biological appl

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 07 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Effect of Dentifrices with Different Abrasives on the Surface Roughness of a Nano Composite Resins materials
...Show More Authors

Background: to evaluate the effect of different dentifrices on the surface roughness of two composite resins (nanofilled-based and nanoceramic – based composite resins). Materials and methods: Forty specimens (diameter 12 mm and height of 2mm) prepared from different composite resin materials: Z350 (nanofilled composite, and Ceram-X (nanoceramic) .they were subjected to brushing simulation equivalent to the period of 1 year. The groups assessed were a control group brushed with distilled water (G1), Opalescence whitening toothpasteR (G2), Colgate sensitive pro-relief (G3) and Biomed Charcoal Toothpaste (G4). The initial and final roughness of each group was tested by surface roughness tester. The results were statistically analyzed using

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Thu Apr 20 2017
Journal Name
International Journal Of Science And Research (ijsr)
Effect of Different Sealer Systems on the Resistance to Vertical-Root-Fracture of Endodontically Treated Tooth
...Show More Authors

Abstract: An unfavorable complication of root canal is vertical root fracture. The aim of present study is to evaluate the vertical root fracture of treated teeth filled with gutta percha and Resilon obturating material using different sealers. Forty mandibular premolars used in the study. Canals randomly divided into four groups (n=10). Group-A eugenol-based (Endofill) sealer with gutta percha; GroupB epoxy-amine (AH Plus) sealer with gutta percha; Group-C resin-based (Real Seal) sealer with Resilon; or Group-D epoxide-based (Perma Evolution) sealer with gutta percha. Roots mounted vertically in cold cure acrylic blocks and subjected to vertical loading with a crosshead speed of 1mm ̸min. The point at which fracture of the roots occurred

... Show More
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Studying the effect of Different wt % AL2O3 Nanoparticles of 2024Al Alloy / AL2O3 Composites on Mechanical Properties
...Show More Authors

 

The nanocompsite of alumina (Al2O3) produced a number of beneficial effects in alloys. There is increasing in resistance of materials to surface related failures , such as the mechanical properties , fatigue and stress corrosion cracking .The experimental results observed that the adding of reinforced  nanomaterials  type Al2O3  enhanced the   HB hardness, UTS, 0.2 YS and ductility of 2014 Al/Al2O3 nano composites . the analysis of experiments, indicated that The maximum enhancement was observed at 0.4 wt.% Al2O3. The ultimate improvement percentage were 15.78% HB hardness, 18.1% (UTS), 12.86% (

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Extraction and estimation of curcumin compounds from turmeric (Curcuma longa) rhizomes by using different variables (solvent, time and temperature).
...Show More Authors

The study aimed to investigate the effect of different times as follows 0.5, 1.00, 2.00 and 3.00 hrs, type of solvent (acetone, methanol and ethanol) and temperature (~ 25 and 50)ºc on curcumin percentage yield from turmeric rhizomes. The results showed significant differences (p? 0.05) in all variables. The curcumin content which were determined spectrophotometrically ranged between (0.55-2.90) %. The maximum yield was obtained when temperature, time and solvent were 50ºC, 3 hrs and acetone, respectively.

View Publication Preview PDF
Crossref
Publication Date
Tue Dec 23 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Immunohistochemical expression of ICAM-1 and Cortactin as cell adhesive molecule and invasive markers in Hodgkin’s and non-Hodgkin’s lymphoma of the head and neck region (A comparative study)
...Show More Authors

Background: Lymphomas are a group of diseases caused by malignant lymphocytes that accumulate in lymph nodes and cause the characteristic clinical features of lymphadenopathy. Intercellular adhesion molecule-1 (ICAM-1) (CD54) is a transmembrane glycoprotein belonging to the immunoglobulin superfamily of adhesion molecules. Cortactin was first identified as one of the major substrates for src kinase. because it localized to Cortical actin structures, The aims of this study was to evaluate and compare the immunohistochemical of ICAM-1 expression as cell adhesion molecule marker and Cortactin expression as invasive marker. Material and Methods: This study was performed on (68) formalin-fixed, paraffin-embedded blocks, histopathologically diagn

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Sensitivity of Streptococcus mutans to Selected Nanoparticles (in Vitro Study)
...Show More Authors

Background: Nanoparticles are clusters of atoms in a size range from (1-100) nm. Nano dentistry creates amazing useful structures from individual atoms or molecules (nanoparticles), which provides a new alternative and a possibly superior strategy in prevention and treatment of dental caries through management of dental plaque biofilms. The aim of the study was to test the sensitivity of Streptococcus mutans to different concentrations of hydroxyapatite and iron oxide nanoparticles suspension solutions, in comparison to chlorhexidine, and de-ionized water, in vitro. Materials and methods: Agar well technique was applied to test the sensitivity of Streptococcus mutans to different concentrations of hydroxyapatite and iron oxide nanoparticle

... Show More
View Publication
Crossref (8)
Crossref
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Bacterial Contamination of Acrylic Resin Complete Denture : In Vitro Study
...Show More Authors

Background: Cross contamination of dental appliances in the dental clinics and laboratories may potentially be a health hazard to the dental team and the patient. This study aimed to evaluate bacterial contamination of acrylic complete denture as received from dental laboratory before delivery to the patient, and then to evaluate the effectiveness of disinfection with 2% chlorhexidine and Kin denture cleaner tablet. Materials and methods: 45 newly made upper complete dentures undergone biaacterial examination for contamination before delivered to the patient. Samples were examined in two stages, first after finishing and polishing; when collected from the laboratory and before inserting to the patient mouth, second; after the samples were

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 23 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Radiopacity of modified microhybrid composite resin:(An in vitro study)
...Show More Authors

Background: The aim of this study was to measure the radiopacity (RO) of modified microhybrid composite resins by adding 2 types of nanofillers (Zinc Oxide and Calcium Carbonate) in two concentrations 3% and 5% and comparing them to unmodified microhybrid composite resins and to nanofilled composite resin. Materials and Methods: Two types of composite resin were used (Microhybrid composite MH Quadrent anterior shine and Nanofilled composite resin Filtek Z350 XT), for each tested group five disk-shaped specimens (1-mm-thick and 15 mm diameter) were fabricated. The material samples were radiographed together with the aluminum step wedge. The density of the specimens was determined with a transmission densitometer and was expressed in term of

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Copper Wires Coated with Enamel
...Show More Authors

View Publication Preview PDF