Preferred Language
Articles
/
jbcd-2210
Assessing The Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness varying from 1mm to 10mm in steps of 1mm each. The tested materials were radiographed, we used Image J software, on a computer screen to evaluate the degree of radiopacity for each individual material and compare with the aluminum step wedge. Radiopacity was expressed in mm of equivalent aluminum step wedge. Analysis of varience (ANOVA) and Least Significant Difference (LSD) were used to investigate the significance of differences among the tested groups. Results: Statistical analysis showed highly significant difference among the tested groups (p≤0.01). Amongst, G-aenial composite shows the most radiopaque and it is above or equivalent to that of enamel, while Estelite Sigma Quick composite has the lowest radiopacity value and is equivalent to that of dentin. Conclusion: In line with previous studies, and within the limitation of our study, considerable variations in radiopacity values were found among materials depending on the radiopaque elements incorporated into the matrix. All composite materials tested complied with the ISO 4049 standard.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun May 12 2019
Journal Name
Oral And Maxillofacial Surgery
Lingual anesthesia of the lower anterior teeth, which technique is better?
...Show More Authors

Purpose To extract the lower anterior teeth, the oral surgeon needs to anesthetize the pulpal tissue of the accused tooth and the surrounding tissues. The lingual nerve innervates the lingual soft tissue to the lower teeth, this nerve usually anesthetized alongside the inferior alveolar nerve by a block technique. However, the lingual tissue of the lower anterior teeth usually anesthetized by either infiltration or periodontal ligament injection (PDL) techniques. This study was intended to compare between these two techniques. Methods Forty-eight teeth were extracted from 24 patients. Non-adjacent two lower anterior teeth in the same patient were selected. The lingual soft tissue in one of them was anesthetized by PDL injection technique wh

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Oct 03 2022
Journal Name
Optik
Enhancement the photosensitivity of PVA NFs/Si prepared by electrospinning technique
...Show More Authors

This work aimed PVA nanofibers in a range of concentrations were successfully manufactured via electrospinning. PVA NFs/Si was effectively prepared using the electrospinning process. The structural, morphological, optical and electrical properties of the prepared PVA were studied using XRD, FE-SEM, UV-Vis spectrophotometer and I-V characteristics, respectively. The amorphous structure of PVA nanofibers was observed. The optical energy gap from ultraviolet to visible was between (2.75 and 2.41) eV, making this compound highly sensitive to visible orange light at 610 nm, with a photosensitivity of 66%. The optical energy gap of PVA/Si heterojunction was utilized to modify this film from the UV to the visible spectrum. As show in the results,

... Show More
Scopus (7)
Scopus
Publication Date
Thu Oct 01 2015
Journal Name
Applied Research Journal
Experimental Study of the Behavior of Composite Concrete Castellated Steel Beams Subjected to Pure Bending
...Show More Authors

The aim of this study is to investigate the behavior of composite castellated beam in which the concrete slab and steel beam connected together with headed studs shear connectors. Four simply supported composite beams with various degree of castellation were tested under two point static loads. One of these beams was built up using standard steel beam, i.e. without web openings, to be a reference beam. The other three beams were fabricated from the same steel I-section with various three castellation ratios, (25, 35, and 45) %. In all beams the concrete slab has the same section and properties. Deflection at mid span of all beams was measured at each 10 kN load increment. The test results show that the castellation process leads to

... Show More
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Effect of Chromium (VI) on the Oxidation of Methylene Blue Dye by Fe3O4/ Chitosan Composite
...Show More Authors

     Heavy metal ion removal from industrial wastewater treatment systems is still difficult because it contains organic contaminants. In this study, functional composite hydrogels with photo Fenton reaction activity were used to decompose organic contaminants. Fe3O4 Nanoparticle, chitosan (CS), and other materials make up the hydrogel. There are different factors that affected Photo-Fenton activity including (pH, H2O2 conc., temp., and exposure period). Atomic force microscopy was used to examine the morphology of the composite and its average diameter (AFM). After 60 minutes of exposure to UV radiation, CS/ Fe3O4 hydrogel composite had degraded methylene blue (M.B.)

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Jul 09 2020
Journal Name
Agrosystems, Geosciences & Environment
Yield and quality of three potato cultivars under series of nitrogen rates
...Show More Authors

Undesirable growth of potato (Solanum tuberosum L.) crop under an excessive N fertilizer application is the main obstacle presently. This research was conducted to investigate the response of different potato cultivars; Russet Burbank, Shepody, and Superior, and its qualitative characteristics under a series of N rates. Six rates of N fertilization (0–280 kg ha−1) were applied on 11 sites in a randomized complete block design, with four replications. Sites with ≥30 g kg−1 of soil organic matter (OM) produced total tuber yield, marketable yield, and tuber weight per plant 39.5, 45.2, and 54.9%, respectively, higher than sites with ≤30 g kg−1 of OM. Tubers specific gravity increased by 0.18% in the sites with ≥30 g kg−1 of OM.

... Show More
View Publication
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
A comparison of the Semiparametric Estimators model smoothing methods different using
...Show More Authors

In this paper, we made comparison among different parametric ,nonparametric and semiparametric estimators for partial linear regression model users parametric represented by ols and nonparametric methods represented by cubic smoothing spline estimator and Nadaraya-Watson estimator, we study three nonparametric regression models and samples sizes  n=40,60,100,variances used σ2=0.5,1,1.5 the results  for the first model show that N.W estimator for partial linear regression model(PLM) is the best followed the cubic smoothing spline estimator for (PLM),and the results of the second and the third model show that the best estimator is C.S.S.followed by N.W estimator for (PLM) ,the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
A New Regimen in the Treatment of Psoriasis Using Oral Methotrexate
...Show More Authors

View Publication
Crossref
Publication Date
Wed Sep 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Methanol Effect on color stability and shelf life of phenolic Resin compound under acidic conditions
...Show More Authors

The object of this work is to investigate the effect of the addition of methanol on the shelf life and color characteristics of novolak resin. Different percentages were added and two mechanisms were suggested for the addition. High ortho structure (1, 2-3) novolak resin was prepared and used in the above investigation. Experimental determination using FT-IR and UV-spectroscopy showed that on the addition of 30% of methanol and according to the second mechanism of addition novolak shelf life increased to 12 months without obvious decomposition and color change. It is suggested that methanol plays an important role in the inhabitation of the reactive sites on the resin that are responsible for the oxidation of the polymer when exposed to

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Mechanical and physical properties of carbon nano tubes with kevlar fiber reinforced with polyester resin
...Show More Authors

In this research study Hardness (shore D), Water absorption,
Flexural, Impact Test, and Fracture Toughness of polymer nano
composites. The polymer nano composites based on unsaturated
polyester resin reinforced with Kevlar fibers (K.F). The samples are
attended by hand lay – up method according to (Rule mixture) for
various volume fractions of unsaturated polyester resin, fiber and
carbon nanotube. The polyester resin was matrix strengthened with
3% volume fraction from Kevlar fiber and (0.5%, 1%, 1.5%, 2%)
volume fractions of carbon nanotube. The water absorption, hardness
(shore D), flexural test, impact test and toughness fracture properties
were studied. Results showed that the water absorption increas

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 22 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Teeth Displacement and Palatal Adaptation of Autoclave Cured acrylic resin with Various Palates and Investments.
...Show More Authors

Background: The denture base inaccuracies during processing negatively influence the retention and stability of finished complete denture. The aims of this study were to evaluate teeth movement and palatal adaptation of autoclave cured denture bases and their relationship with palatal depths and investments. Materials and methods: A nightly maxillary complete dentures prepared, processed and organized to be tested as follows: 1. Processing methods: water bath and autoclave with both fast and slow cycles. 2. Palatal depth: shallow, medium and deep. 3. Investing medium: stone and silicone. For every finished denture, two measurements were done: first: teeth movement by attaching metallic reference screws on the right and left centrals, first

... Show More
View Publication Preview PDF
Crossref (2)
Crossref