Background: Complete seal of the root canal system following its chemo-mechanical debridement plays a pivotal role for achieving successful endodontic treatment. This can be established by reducing the gaps between the core filling material and root canal wall. Aim: To assess and compare the dislocation resistance of root canals obturated with GuttaFusion® and TotalFill BC sealer versus single cone obturation technique and TotalFill BC sealer after instrumentation of the canals with WaveOne, ProTaper Next and ProTaper Universal system. Material and Method: Sixty extracted human permanent mandibular premolars were conducted in the current study. The teeth were decorated and left the root with 15mm length; the roots were divided randomly into three main groups, twenty roots in each group. The roots were instrumented with different rotary systems using crown down technique according to the groups: (Group I) was instrumented with WaveOne files. (Group II) was instrumented with ProTaper Next system and (Group III) was instrumented with ProTaper Universal system. For each group the same irrigation regimen was used, 3 mL of 5.25% sodium hypochlorite and 3 mL of 17% EDTA to remove the smear layer. Then, Group I was also subdivided randomly into two subgroups of ten samples each, (Group I A) obturated with single cone gutta-percha and (Group I B) filled with GuttaFusion®. Group II was divided into (Group II A) obturated with single cone gutta-percha and (Group II B) filled with GuttaFusion®. Group III was divided into (Group III A) obturated with single cone gutta-percha and (Group III B) obturated with GuttaFusion®. In the present study, TotalFill BC sealer was used for all the tested groups. Then, the roots were embedded in clear acrylic resin and each root sectioned into three sections of 2mm thick (apical, middle and coronal). The push-out bond strength values represented by (MPa) unit was calculated by dividing the load on the surface area and the last was measured in collaboration with AutoCAD system software program. Failure mode analysis was carried out to examine the type of failure in each sample by using a stereomicroscope. Results: The results showed highly significant differences among the main groups that instrumented with different rotary systems (WaveOne, ProTaper Next and ProTaper Universal system). There were highly significant differences between the two obturation techniques of the subgroups (single cone gutta-percha versus GuttaFusion®). However; Gutta-Fusion® showed highest bond strength value than single cone obturation technique. The coronal third slices of all groups showed highest value of bond strength in comparison to the middle thirds and apical thirds. In the meantime, the middle third slices showed bond strength higher than that of the apical thirds for all groups. Statistical analysis was performed by using two way ANOVA and LSD tests. Conclusions: The instrumentation techniques and the obturation materials significantly affected the push-out bond strength values of obturation system. The highest value was appointed in root canals instrumented with ProTaper Universal System; obturated with GuttaFusion® and BC sealer, whereas, the lowest bond strength was appeared at canals instrumented with ProTaper Next; obturated with single cone gutta-percha and BC sealer.
Solvent- free thermal heating, one-pot condensation of acetophenone, ethyl cyanoacetate or malononitrle and substituted Aromatic aldehyde, ammonium acetate give, 2oxo-3-cyano-4-substituted Aryl-6-phenyl pyridine [I]a-h , or 2-amino-3-cyano-4-substituted Aryl-6-phenyl pyridine derivatives[II]a-f , respectively. Treatment of compounds 2-oxo-3-cyano-4-substituted Aryl-6-phenyl pyridine with phosphorous penta sulphide (P2S5), give 2-thioxo-3-cyano-4-substituted Aryl-6-phenyl pyridine derivatives[III]a-c . All prepared compounds
... Show MoreNew Schiff base, namely [2-(carboxy methylene-amino)-phenyl imino] acetic acid (L) and its some metal complexes [LCo.2H2O], [LNi.2H2O], [LCu].3H2O, [LCd.2H2O], [LHg.2H2O] and [LPb.2H2O], were reported and characterized by elemental analysis, metal content, spectroscopic methods, magnetic moments and conductivity measurements, it is found that the geometrical structures of these complexes are octahedral [Co(II), Ni(II), Cd(II), Hg(II), Pb(II) and square planar Cu(II).The complexes have been found to posses 1:1 (M:L) stoichiometry
Diabetic nephropathy (DN) is the most common microvascular complication that may lead to chronic renal failure in diabetic patients. Till now microalbuminuria, with its restrictions, is the early marker of DN, appeared after the disease exacerbation. Thus, new biomarkers are required to predict the early onset of DN before the appearance of microalbuminuria. The aim of this study is to investigate the possible use of uVDBP in the early prediction of DN. Fifty diabetic patients with DN and 40 diabetic patients without DN for both types of diabetes were enrolled in this study. All patients were tested for uACR, uVDBP (measured by ELISA), and blood HbA1c. The results demonstrated a highly significant elevation of uAC
... Show MoreTwo tetradentate ligands type (N2O2) and their complexes with CoII, NiII and ZnII ions were synthesized via two steps; in the first, the precursors W1 and W2 were synthesized from the reaction of 2,6-diamine pyridine or 2,4-diamine tolylene with 2,5-hexanedione respectively in a 2:1 mole ratio. In the second step the ligands [H2L1] and [H2L2] were prepared from the reaction of the two precursor’s with 2-hydroxy-1-naphthaldehyde in 1:2 mole ratio. Metal complexes were synthesized by the reaction of the ligands with equivalent amounts of the metal chloride. The prepared compounds were characterized with the
... Show MoreThere is currently a pressing need to create an electro-analytical approach capable of detecting and monitoring genosensors in a highly sensitive, specific, and selective way. In this work, Functionalized Multiwall Carbon Nanotubes, Graphene, Polypyrrole, and gold nanoparticles nanocomposite (f-MWCNTs-GR-PPy-AuNP) were effectively deposited on the surface of the ITO electrode using a drop-casting process to modify it. The structural, morphological, and optical analysis of the modified ITO electrodes was carried out at room temperature using X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM) images, atomic force microscopy (AFM) and Fourier transform infrared (FTIR) spectra. Cyclic voltammetry (CV) and electrochemi
... Show MorePera Magroon anticline is located within the northeastern of Iraq, covering area estimated by 958 Km2. The Landsat ETM+ false color composite imagery was produced by assigning [741] bands. It is used to distinguish alluvial fans in the southwestern limb of Pera Magroon anticline. Digital elevation models (DEM) were used for describing topographic features related to the alluvial fans, as well as, three dominations model (3D) was created from (DEM) and the Landsat ETM+ image.
Arc GIS, hydro tool set was used to draw the drainage patterns, the area of study was covered by dendritic and parallel patterns. Contour lines across the fans form segments of ellipses reveal the pattern of tectonic act
... Show MoreIn this work, the nuclear density distributions, size radii and elastic electron scattering form factors are calculated for proton-rich 8B, 17F, 17Ne, 23Al and 27P nuclei using the radial wave functions of Woods-Saxon potential. The parameters of such potential for nuclei under study are generated so as to reproduce the experimentally available size radii and binding energies of the last nucleons on the Fermi surface.
Herein, the interfacial polymerization method has been used for the synthesis of PPy/NaVO3 composites with different compositions of NaVO3 (10 %, 20 %, 30 %, 40 % and 50 %) as an efficient electrode material for supercapacitors. The successful formation and composition of the as-prepared composites (PV1-PV5) were confirmed by FTIR, XRD, EDX, and SEM analysis. The electrochemical properties were investigated by cyclic voltammetry (CV), galvanometric charge–discharge measurement (GCD), and electrochemical impedance spectroscopy (EIS) in 0.5 M H2SO4 electrolyte. As compared to other, the PV4 composite exhibit excellent specific capacitance of 391 F g−1 at a current density of 0.75 A/g with good cycling stability of ∼59 % after 1000 cycle
... Show More