Background: Complete seal of the root canal system following its chemo-mechanical debridement plays a pivotal role for achieving successful endodontic treatment. This can be established by reducing the gaps between the core filling material and root canal wall. Aim: To assess and compare the dislocation resistance of root canals obturated with GuttaFusion® and TotalFill BC sealer versus single cone obturation technique and TotalFill BC sealer after instrumentation of the canals with WaveOne, ProTaper Next and ProTaper Universal system. Material and Method: Sixty extracted human permanent mandibular premolars were conducted in the current study. The teeth were decorated and left the root with 15mm length; the roots were divided randomly into three main groups, twenty roots in each group. The roots were instrumented with different rotary systems using crown down technique according to the groups: (Group I) was instrumented with WaveOne files. (Group II) was instrumented with ProTaper Next system and (Group III) was instrumented with ProTaper Universal system. For each group the same irrigation regimen was used, 3 mL of 5.25% sodium hypochlorite and 3 mL of 17% EDTA to remove the smear layer. Then, Group I was also subdivided randomly into two subgroups of ten samples each, (Group I A) obturated with single cone gutta-percha and (Group I B) filled with GuttaFusion®. Group II was divided into (Group II A) obturated with single cone gutta-percha and (Group II B) filled with GuttaFusion®. Group III was divided into (Group III A) obturated with single cone gutta-percha and (Group III B) obturated with GuttaFusion®. In the present study, TotalFill BC sealer was used for all the tested groups. Then, the roots were embedded in clear acrylic resin and each root sectioned into three sections of 2mm thick (apical, middle and coronal). The push-out bond strength values represented by (MPa) unit was calculated by dividing the load on the surface area and the last was measured in collaboration with AutoCAD system software program. Failure mode analysis was carried out to examine the type of failure in each sample by using a stereomicroscope. Results: The results showed highly significant differences among the main groups that instrumented with different rotary systems (WaveOne, ProTaper Next and ProTaper Universal system). There were highly significant differences between the two obturation techniques of the subgroups (single cone gutta-percha versus GuttaFusion®). However; Gutta-Fusion® showed highest bond strength value than single cone obturation technique. The coronal third slices of all groups showed highest value of bond strength in comparison to the middle thirds and apical thirds. In the meantime, the middle third slices showed bond strength higher than that of the apical thirds for all groups. Statistical analysis was performed by using two way ANOVA and LSD tests. Conclusions: The instrumentation techniques and the obturation materials significantly affected the push-out bond strength values of obturation system. The highest value was appointed in root canals instrumented with ProTaper Universal System; obturated with GuttaFusion® and BC sealer, whereas, the lowest bond strength was appeared at canals instrumented with ProTaper Next; obturated with single cone gutta-percha and BC sealer.
One of the most common procedures in oral surgery is the removal of impacted mandibular third molars, often followed by pain, swelling, alveolitis, and trismus. Purpose. To compare the outcomes of the intrasocket application of 1% hyaluronic acid oral gel (HA) and advanced platelet-rich fibrin (A-PRF) on the expected postoperative complications, pain, swelling, and trismus follow the surgical extraction of the impacted mandibular third molar. Material and Methods. A randomized controlled trial was conducted at the Oral and Maxillofacial Surgery Unit, Dental Teaching Hospital. Healthy patients who required surgical removal of the impacted mandibular third molar were divided randomly into three groups. The extraction site of the group
... Show MoreThis article aims to establish and evaluate standards for critical equipment and materials in highway projects in Iraq. Delphi technique has been used to analyze, explore, and discover the main criteria and sub-criteria that affect equipment and materials in highway construction projects in Iraq. To determine the correct response to the criteria presented in this study, a program (IBM, SPSS/V25) was used to assess the main criteria and sub-criteria using the mean score (MS) and standard deviation (SD) technique, as well as to check reliability using Cronbach's alpha factor (α). The experts' qualifications and the extent to which the person is ready to commit are both important factors in panel selection. The design of a
... Show MoreThe performance of single and two stage solar concentrator were studied ' " The ratio of the primary to the secondary mirrors diameter is taking to be 0.5, depending on the theoretical calculation for the accumulated energy by the concentrator with ratio between 0.0 to 0.9. The design of the systems were designed and examined by using a ray-tracing program. The efficiency of the single and the two stage concentrators are calculated and compared with and without cooling systems.
In this paper, a single-phase boost type ac-dc converter with power factor correction (PFC) technique is designed and implemented. A current mode control at a constant switching frequency is used as a control strategy for PFC converter. The PFC converter is a single-stage singleswitch boost converter that uses a current shaping technique to reshape the non-sinusoidal input current drawn by the bulky capacitor in the conventional rectifier. This technique should provide an input current with almost free-harmonics, comply with the IEC61000-3-2 limits, and a system operates with near unity power factor. The other function of the boost converter that should be
accomplished is to provide a regulated DC output voltage. The complete designed
Abstract
Robotics manipulators with structural flexibility provide an attractive alternative to rigid robotics manipulators for many of the new and evolving applications in robotics. In certain applications their use is unavoidable. The increased complexity in modeling and control of such manipulators is offset by desirable performance enhancements in some respects. In this paperthe single- link flexible robotics manipulator was designed and implemented from Perspex and designed with 0.5 m length , 0.02 m width and with 0.004 m thickness with mass located at the tip. There are four subsystems; motion, control, accelerometer and gyro and a host computer subsystem. The work principle of single-link robotics manipul
... Show MoreBackground Anorectal carcinoma includes the anal margin, the anal canal, and the lower rectum. The incidences of anal tumors represent 1.4 % of all gastrointestinal tumors.
Patients and methods Our study is retrospective and was conducted at Baghdad Medical City. Patient’s data were collected from the medical records through a predesigned sheet that included the following information: demographic data, medical history, past-history, presenting symptoms, pathological data, and treatment details.
Results The median age was 49 years. As regard tumor extension, 85.71 % of patients had anal disease, while anorectal cancer was encount
Background: In capturing a negative image, the digital impression secures a digital record for the purposeof designing and creating restorations. The introduction of scanning system presents a paradigm shift in the way of the dental impression procedure and encourages the accuracy of obtained restoration especially in the marginal area as a result of producing accurate final impression The digital system offers many advantages over the Conventional method.. The objective of this present in vitro study was to evaluate the marginal fitness of all ceramic crowns fabricated by direct digital scanning of the prepared tooth using two types of intra-oral cameras (Bluecam camera with strip light projection technique and Omnicam camera with video sa
... Show MoreUndoped and Iodine (I)–doped chrome oxide (Cr2O3)thin films have been prepared by chemical spray pyrolysis technique at substrate temperatures(773K) on glass substrate. Absorbance and transmittance spectra have been recorded as a function of wavelength in the range (340-800 nm) in order to study the optical properties such as reflectance, Energy gap of allowed direct transition, extinction coefficient refractive index, and dielectric constant in real and imagery parts all as a function of wavelength. It was found that all the investigated parameters affect by the doping ratios.
The Ground Penetrating Radar (GPR) is frequently used in pavement engineering
for road pavement inspection. The main objective of this work is to validate
nondestructive, quick and powerful measurements using GPR for assessment of subgrade
and asphalt /concrete conditions. In the present study, two different antennas
(250, 500 MHz) were used. The case studies are presented was carried in University
of Baghdad over about 100m of paved road. After data acquisition and radar grams
collection, they have been processed using RadExplorer V1.4 software
implementing different filters with the most effective ones (time zero adjustment and
DC removal) in addition to other interpretation tool parameters.
The interpretatio