Background: Complete seal of the root canal system following its chemo-mechanical debridement plays a pivotal role for achieving successful endodontic treatment. This can be established by reducing the gaps between the core filling material and root canal wall. Aim: To assess and compare the dislocation resistance of root canals obturated with GuttaFusion® and TotalFill BC sealer versus single cone obturation technique and TotalFill BC sealer after instrumentation of the canals with WaveOne, ProTaper Next and ProTaper Universal system. Material and Method: Sixty extracted human permanent mandibular premolars were conducted in the current study. The teeth were decorated and left the root with 15mm length; the roots were divided randomly into three main groups, twenty roots in each group. The roots were instrumented with different rotary systems using crown down technique according to the groups: (Group I) was instrumented with WaveOne files. (Group II) was instrumented with ProTaper Next system and (Group III) was instrumented with ProTaper Universal system. For each group the same irrigation regimen was used, 3 mL of 5.25% sodium hypochlorite and 3 mL of 17% EDTA to remove the smear layer. Then, Group I was also subdivided randomly into two subgroups of ten samples each, (Group I A) obturated with single cone gutta-percha and (Group I B) filled with GuttaFusion®. Group II was divided into (Group II A) obturated with single cone gutta-percha and (Group II B) filled with GuttaFusion®. Group III was divided into (Group III A) obturated with single cone gutta-percha and (Group III B) obturated with GuttaFusion®. In the present study, TotalFill BC sealer was used for all the tested groups. Then, the roots were embedded in clear acrylic resin and each root sectioned into three sections of 2mm thick (apical, middle and coronal). The push-out bond strength values represented by (MPa) unit was calculated by dividing the load on the surface area and the last was measured in collaboration with AutoCAD system software program. Failure mode analysis was carried out to examine the type of failure in each sample by using a stereomicroscope. Results: The results showed highly significant differences among the main groups that instrumented with different rotary systems (WaveOne, ProTaper Next and ProTaper Universal system). There were highly significant differences between the two obturation techniques of the subgroups (single cone gutta-percha versus GuttaFusion®). However; Gutta-Fusion® showed highest bond strength value than single cone obturation technique. The coronal third slices of all groups showed highest value of bond strength in comparison to the middle thirds and apical thirds. In the meantime, the middle third slices showed bond strength higher than that of the apical thirds for all groups. Statistical analysis was performed by using two way ANOVA and LSD tests. Conclusions: The instrumentation techniques and the obturation materials significantly affected the push-out bond strength values of obturation system. The highest value was appointed in root canals instrumented with ProTaper Universal System; obturated with GuttaFusion® and BC sealer, whereas, the lowest bond strength was appeared at canals instrumented with ProTaper Next; obturated with single cone gutta-percha and BC sealer.
Background: Several infectious lung diseases often develop in patients with Rheumatoid arthritis (RA), especially during immunosuppressive medication, including disease-modifying anti-rheumatic drugs (DMARDs). The present study aimed to determine the role of respiratory tract bacterial infection in RA activity. Methods: Blood and sputum samples were collected from 31 patients with RA and 12 healthy subjects as control. The bacterial isolates were isolated and identified in collected sputum by biochemical tests and Vitec 2 system. Results: In the present study, thirty-one patients with RA were compared with 12 healthy subjects. Eight patients with RA were not infected with pathogenic bacteria (RA-NIPB) (25.8%). Twenty-three RA patients wer
... Show MoreThis research studies the effect of addition of some nanoparticles
(MgO, CuO) and grain size (30,40nm) on some physical properties
(impact strength, hardness and thermal conductivity) for a matrix
blend of epoxy resin with SBR rubber. Hand –Lay up method was
used to prepare the samples. All samples were immersed in water for
9 weeks.
The Results showed decreased in the values of impact strength and
hardness but increased the coefficient of thermal conductivity.
Construction joints serve as interruption points in the concrete placement process, which is necessary because it is often not feasible to pour concrete continuously in many structures. The quantity of concrete that can be poured at a single instance depends on the batching and mixing capacity, as well as the strength of the formwork. An effective construction joint must ensure sufficient flexural and shear continuity across the junction. Many studies investigated the construction joints in the reinforced concrete (RC) normal beams, but there are no studies investigating the effect of construction joints on the behavior of the RC deep beams. This study was prepared to show the behavio
Background: Successful root canal therapy depends on thorough chemo mechanical debridement of pulpal tissue, dentin debris and infective microorganisms. Objective: This study aimed to investigate the antibacterial effect of silver nanoparticles, sodium hypochlorite and chlorhexidine in reducing the bacterial infection of the root canals. Materials and Methods: The root canals of 55 single-rooted teeth were cleaned, shaped, and sterilized. All the teeth samples were inoculated with Enterococcus faecalis and incubated at 37°C for 2 weeks. Then, the teeth were divided into four groups. Group I (n=15): 100 ppm silver nanoparticles, Group II (n=15): 2.5 sodium hypochlorite, Group III (n=15): 2% chlorhexidine, IV (n=10): Normal saline as a contr
... Show MoreModeling data acquisition systems (DASs) can support the vehicle industry in the development and design of sophisticated driver assistance systems. Modeling DASs on the basis of multiple criteria is considered as a multicriteria decision-making (MCDM) problem. Although literature reviews have provided models for DASs, the issue of imprecise, unclear, and ambiguous information remains unresolved. Compared with existing MCDM methods, the robustness of the fuzzy decision by opinion score method II (FDOSM II) and fuzzy weighted with zero inconsistency II (FWZIC II) is demonstrated for modeling the DASs. However, these methods are implemented in an intuitionistic fuzzy set environment that restricts the ability of experts to provide mem
... Show MoreWrestling Judo, one of the sports that have seen greatdevelopment in recent years in the world, requiring preparationphysically special, which is to be determined physical aptitude of thebad functional efficiency of the heart and lungs, Efficient physicalclosely linked to the ability of the player performance, as the physicalaptitude to play an important role the possibility of control over theaspects and physical skills during training and competition.The study aims to determine the effect of training on anaerobicendurance according to the average (30-60 sec) in the development ofphysical aptitude for judo players. Used a much more extremeexperimental method on a sample was Blaabat national teamwrestling judo and numbers of 16 for the play
... Show MoreIn this experimental and numerical analysis, three varieties of under-reamed piles comprising one bulb were used. The location of the bulb changes from pile to pile, as it is found at the bottom, center, and top of the pile, respectively.
The triggering effect for the face pumping of Nd:YVO4 disc medium of 4×5×0.5 mm was investigated using bulk diode laser at different resonator cavity length in pulse mode and at repetition rate of 1.3kHz. The maximum emitted peak power was found to be 100, 82, and 66 mW for resonator lengths of 10, 13.5, and 17.5 cm respectively, while the threshold pumping power was found to be 41mW. The maximum emitted peak power obtained was 300 mW when using external triggering and 10cm length, with repetition of 3Hz.
