Preferred Language
Articles
/
jbcd-211
Evaluation of frictional forces generated by different brackets and orthodontic wires
...Show More Authors

Background: Sliding mechanics is widely used during orthodontic treatment. One of the disadvantages of this mechanics is the friction generated at the bracket/archwire interface, which may reduce the amount of desired orthodontic movement obtained. The aim of the present in vitro study was to evaluate and compare the static frictional forces produced by two passive self-ligating brackets stainless-steel and hybrid and two conventional brackets stainless-steel and monocrystal ligated with stainless-steel ligature wire at two degrees of torque(zero and twenty) under dry condition. Materials and method: One hundred and sixty brackets were used in this study divided into four groups each group consisted of forty brackets these are: Two self-ligating (stainless-steel and Hybrid) while the two conventional types are the (stainless-steel and monocrystal).twenty of each group examined with 0.016"x0.022"archwire, ten at 0? torque and ten at 20? torque while the other twenty of each group examined with 0.019"x0.025", ten at 0? torque and ten at 20? torque. Results: There was a significant different between all groups except in case when self-ligating brackets (both types) ligated to both wires at 0?torque there was no significant difference. Conclusions: The self- ligating brackets produce significantly lower static friction than the conventional types at both degrees of torque. There was no significant different between both self-ligating brackets at0?torque while at 20? torque the stainless- steel self –ligating produce lower static friction than the clear self-ligating type.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Preparation of TiO2 nanorods by Sol–Gel template method and measured its photo- catalytic activity for degradation of methyl orange
...Show More Authors

Titanium dioxide nanorods have been prepared by sol-gel template
method. The structural and surface morphology of the TiO2 nanorods was
investigated by X-ray diffraction (XRD) and atomic force microscopy
(AFM), it was found that the nanorods produced were anatase TiO2 phase.
The photocatalytic activity of the TiO2 nanorods was evaluated by the
photo degradation of methyl orange (MO). The relatively higher
degradation efficiency for MO (D%=78.2) was obtained after 6h of exposed
to UV irradiation.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Apr 05 2023
Journal Name
Journal Of Engineering
Effect of Nb Addition on Hardness and Wear Resist of Cu-Al-Ni Shape Memory Alloy Fabricated By Powder Metallurgy
...Show More Authors

Cu-Al-Ni shape memory alloy specimens has been fabricated using powder metallurgy technique with tube furnace and vacuum sintering environment , three range of Nb powder weight percentage (0.3,0.6,0.9)% has been added. Micro hardness and sliding wear resist has been tested followed by X-ray diffraction, scanning electron microscope (SEM) and energy dispersive X-ray spectroscope (EDX) for micro structure observation. The experimental test for the samples has showed that the increase of Nb powder weight percentage in the master alloy has a significant effect on increasing the hardness and decreasing the wear resist therefore it will enhance the mechanical properties for this alloy.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 24 2025
Journal Name
Plos One
Assessment of the bypass of obturation materials beyond fractured instruments after using different obturation techniques in simulated curved canals (An in-vitro study)
...Show More Authors

This study evaluated the extent to which obturation materials bypass fractured endodontic instruments positioned in the middle and apical thirds of severely curved simulated root canals using different obturation techniques. Sixty resin blocks with simulated root canals were used, each with a 50° curvature, a 6.5 mm radius of curvature, and a length of 16.5 mm, prepared to an ISO #15 diameter and taper. Canals were shaped using ProTaper Universal files (Dentsply Maillefer) attached to an X-smart Plus endo motor (Dentsply), set at 3.5 Ncm torque and 250 rpm, up to size S2 at working length. To simulate fractures, F2 and F3 files were weakened 3 mm from the tip, then twisted to break in the apical and middle sections of the canal, re

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Wed Nov 07 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
The Effect of Different Types of Separating Medium On Some Physical Properties of Processing Acrylic Denture-base with Two Investment Materials: A comparative Study
...Show More Authors

Objective(s): In the present study, glycerin is used as a substitute for tin-foil and cold mold seal (Alginate mould seal)
in the process of curing heat and cold-cure acrylic resin denture base against stone and plaster.
Methodology: 60 specimens were prepared from heat-cure acrylic resin and cold-cure acrylic resin denture base. The
study includes 12 groups of specimens depending on the type of processing, investment material and type of
separating medium that are used in curing process. Each group of them contains 5 specimens for each test.
Some of physical properties of the processed acrylic denture base that (water sorption and solubility) have been
compared with those processed using tin-foil and tin-foil substitut

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
Chemical And Process Engineering Research
SYNTHESIS, Spectroscopic Characterization and Evaluation (Antibacterial & (GOT, G pT) Enzyme )Activity of Mixed Ligand Complexes of M(II) with Amino Acid (L-Asparagine) and Schiff Bases Derived from (Sulfamethoxazo Drug with 2,4Dimethoxybenzaldehyde)
...Show More Authors

The research includes the synthesis and identification of the mixed ligands complexes of M 2 Ions in general composition ,[M(Leu) 2 (SMX)] Where L leucine (C 6 H 13 NO 2 )symbolized (LeuH) as a primary ligand and Sulfamethoxazole C 10 H 11 N 3 O 3 S) symbolized (SMX)) as a secondary ligand . The ligands and the metal chlorides were brought in to reaction at room temperature in(v/v) ethanol /water as solvent containing NaOH. The reaction required the following [(metal: 2(Na Leu --): (SMX )] molar ratios with M(II) ions, Were M (  Mn ( II),Co (II),Ni(II),Cu( II),Zn (II),Cd(II)and Hg( The UV Vis and magnetic moment data revealed an octahedral geometry around M(II), The conductivity data show a non electrolytic nature of the complexes . The

... Show More
Preview PDF
Publication Date
Sun Jan 18 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the effect of sodium fluoride addition on some mechanical properties of heat cure acrylic denture base materials
...Show More Authors

Background: The geriatric patients wearing removable partial dentures are increasing in proportion. At the same time, the root caries prevalence accompanied by gingival recession is increasing. A variety of vehicles can deliver fluoride into the oral cavity, including fluoride mouth-rinse, fluoride dentifrice, topical fluoride, and fluoride-releasing restorative materials, all of which effectively prevent root caries and suppress recurrent caries. This study aimed to evaluate the effect of sodium fluoride addition on some mechanical properties of heat cure acrylic denture base material. Material and method: A total of 90 samples were prepared in this study, then divided into three main groups according to the type of test used (hardness, te

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 01 2015
Journal Name
Journal Of Engineering
Determination of the Optimum Conditions in Evaluation of Kiwi Juice as Green Corrosion Inhibitor of Steel in Hydrochloric Acid
...Show More Authors

The corrosion protection of low carbon steel in 2.5 M HCl solution by kiwi juice was studied at different temperatures and immersion times by weight loss technique. To study the determination of the optimum conditions from statistical design in evaluation of a corrosion inhibitor, three variables, were considered as the most dominant variables. These variables are: temperature, inhibitor concentration (extracted kiwi juice) and immersion time at static conditions.

These three variables are manipulated through the experimental work using central composite rotatable Box – Wilson Experimental Design (BWED) where second order polynomial model was proposed to correlate the studied variables with the corrosion rate o

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 01 2020
Journal Name
Diyala Journal Of Medicine
Histological Evaluation of Local Application of Flavonoid Extract of Capparis Spinosa on Wound Healing in Alloxan-Induced Diabetic Rats
...Show More Authors

View Publication
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the effect of preheating on micro leakage of Class II composites Restoration (A comparative in vitro study)
...Show More Authors

Background: The aim of this in vitro study was to evaluate and compare the effect of preheating microleakage among three different filler size composites which include Filtektm Z250 micro hybrid, Z250xt Nano hybrid and nanocomposite Z350xt.  in Class II cavity preparation .

Materials and methods: sixty maxillary first premolars were prepared with class II cavities. Samples were divided into three groups according to material used    group A (FiltekZ250 micro hybrid). Group B(Z250xt Nano hybrid). Group C (nanocomposite Z350xt)and each group divided into two subgroups of ten teeth according to temperature of  composite:

... Show More
View Publication
Crossref
Publication Date
Sun Jan 18 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the effectiveness of coenzyme Q10 gel in management of patients with chronic periodontitis (I intra group comparison)
...Show More Authors

Background: Periodontal pathogens can induce free radicals over-formation and thus may cause collagen and periodontal destruction. Anti-oxidants are used as supplements to counteract the over production of free radicals in periodontal disease, that can reduce of collagen destruction. Coenzyme Q10 serves as an endogenous antioxidant, regenerates other antioxidants, stimulates cell growth, and inhibits cell death. Because it is an antioxidant, coenzyme Q10 has received much research attention associated with periodontal diseases. Perio Q gel may possibly be effective as a topical agent and as an adjunct to scaling& root planing in treatment of gingivitis and chronic periodontitis. Aim of study:Determine the periodontal health status in a foll

... Show More
View Publication Preview PDF