Background: Rheumatoid arthritis is an autoimmune disease that affects mainly the synovial membranes and articular structures and is characterized by chronic, systemic inflammation involving multiple joints.Being a synovial joint, the Temporomandibular Joint is subject to the same disorders affecting other synovial joints, including RA.Beside it was considered as a specific serological marker for diagnosing RA disease ,antibodies to cyclic citrullinated peptide have proven to be associated with joints destruction, though; it may play a potential role in the prediction of the disease severity. Materials and Methods: Sixty nine individuals (69) were enrolled in this study, forty nine (49) were patients diagnosed with Rheumatoid Arthritis, and twenty (20) were healthy control subjects. Blood and saliva samples were taken from each subject for immunological analysis of Anti-Cyclic Citrullinated Peptides antibodies by ELISA. Each patient with Rheumatoid Arthritis disease was examined by means of Research Diagnostic Criteria for Temromandibular Disorders for the assessment of tempromandibularjoint involvement. Results: Frequency of positive serum Anti-CCP antibodies was higher in rheumatoid arthritis patients compared to healthy controls (p=0.000).Tempromandibular joint clinical findings were bilaterally involved except joint sounds, sometimes; it was unilateral. Chronic rheumatoid arthritis patients associated with higher prevalence of tempromandibular joint disorders than newly diagnosed RA, except limited mouth opening which were prevalent in newly diagnosed RA patients, (p=0.012) was significant.Positive serum Anti-CCP rheumatoid arthritis patients were associated with higher frequency of tempromandibular joint disorderscompared with RA patients with negative serum Anti-CCP, a non-significant difference was found. Conclusions:Anti-Cyclic Citrullinated Peptide antibodies are considered as a biomarker of inflammation and disease activity. Tempromandibular joint disorders are frequently involved in rheumatoid arthritis patients. Rheumatoid arthritis patients with positive serum Anti-Cyclic Citrullinated Peptides antibodies associated with higher frequency of tempromandibular joint disorders.
Reliability is an essential measure and important component of all power system planning and operation procedures. It is one of the key design factors when designing complex, critical and expensive systems. This paper presents a fuzzy logic approach for reliability improvement planning purposes. Evaluating the reliability of the complex and large planned Iraqi super grid ;as Al- Khairat generating station with its tie set is intended to be compact to that grid; and determination of the given reliability improvement project are the major goals of the paper. Results show that the Iraqi super grid reliability is improved by 9.64%. In the proposed technique, fuzzy set theory is used to include imprecise indices of different components in normal
... Show MoreBackground: The main aim of the present study is to qualify and quantify voids formation of root canals obturated with GuttaCore (GC) and experimental Hydroxyapatite polyethylene (HA/PE) as new carrier-based root canal fillings by using micro computed tomography scan. Materials and methods: In the present study, eight straight single-rooted human permanent premolar teeth are selected and disinfected, then stored in distilled water. The teeth decoronated leaving a root length of 12mm each. The root canals instrumented by using crown down technique and the apical diameter of the root canal prepared to a size # 30/0.04 for achieving standardized measurements. A 5mL of 17% EDTA used to remove the smear layer followed by 5mL of 2.5% NaOCl and r
... Show MoreThis study introduced the effect of using magnetic abrasive finishing method (MAF) for finishing flat surfaces. The results of experiment allow considering the MAF method as a perspective for finishing flat surfaces, forming optimum physical mechanical properties of surfaces layer, removing the defective layers and decreasing the height of micro irregularities. Study the characteristics which permit judgment parameters of surface quality after MAF method then comparative with grinding
A computerized investigation has been carried out on the design of six electrodes electrostatic lenses used in electron gun application. The Finite-Element Method (FEM) was used in the solution of Laplace equation for determine the axial potential distribution. The electron trajectory under zero magnification condition. The optical properties, spherical and chromatic aberrations, the object and image focal length and object and image position are calculated. A very good futures for the electron gun with these lenses have been computed where are a beam current of 8.7*10-7A can be supplied using cathode tip of radius 10nm.
The electrospun nanofibers membranes have gained considerable interest in water filtration applications. In this work, the fabrication and characterization of the electrospun polyacrylonitrile-based nonwoven nanofibers membrane are reported. Then, the membrane's performance and antifouling properties were evaluated in removing emulsified oil using a cross flow filtration system. The membranes were fabricated with different polyacrylonitrile (PAN) concentrations (8, 11, and 14 wt. %) in N, N-Dimethylformamide (DMF) solvent resulted in various average fiber sizes, porosity, contact angle, permeability, oil rejection, and antifouling properties. Analyses of surface morphology of the fabricated membranes before and after oil removal revealed
... Show MoreFire is one of the most critical risks devastating to human life and property. Therefore, humans make different efforts to deal with fire hazards. Many techniques have been developed to assess fire safety risks. One of these methods is to predict the outbreak of a fire in buildings, and although it is hard to predict when a fire will start, it is critical to do so to safeguard human life and property. This research deals with evaluating the safety risks of the existing building in the city of Samawah/Iraq and determining the appropriateness of these buildings in terms of safety from fire hazards. Twelve parameters are certified based on the National Fire Protection Association (NFPA20