Preferred Language
Articles
/
jbcd-193
Radiopacity of modified microhybrid composite resin:(An in vitro study)
...Show More Authors

Background: The aim of this study was to measure the radiopacity (RO) of modified microhybrid composite resins by adding 2 types of nanofillers (Zinc Oxide and Calcium Carbonate) in two concentrations 3% and 5% and comparing them to unmodified microhybrid composite resins and to nanofilled composite resin. Materials and Methods: Two types of composite resin were used (Microhybrid composite MH Quadrent anterior shine and Nanofilled composite resin Filtek Z350 XT), for each tested group five disk-shaped specimens (1-mm-thick and 15 mm diameter) were fabricated. The material samples were radiographed together with the aluminum step wedge. The density of the specimens was determined with a transmission densitometer and was expressed in term of equivalent thickness of aluminum. Data analyzed by one-way ANOVA. Results: The radiopacity (RO) values of the tested group ranged between (0.9293- 2.6242 Eq. Al thickness) and there were significant differences among them. Nanofilled composite resin Filtek Z350 XT showed the highest value of RO while unmodified Microhybrid composite MH Quadrent anterior shine showed the lowest value of RO. Conclusion: The addition of 3% of both the ZnO and CaCO3 nanofillers fillers to microhybrid composite significantly increased the RO, while the addition of 5% of CaCO3 and ZnO nanofillers to microhybrid composite showed non-significant increase in the RO of the composite.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
In Vitro Cytotoxicity Study of Pt Nanoparticles Decorated TiO2 Nanotube Array
...Show More Authors

Titanium dioxide nanotubes were synthesized by anodizing Ti sheets in the ethylene glycol solution and were covered in Pt nanoparticles onto the surface of TiO2NTs using electrodeposition method from using five derivatives of Mannich base Pt complexes which have been used as precursor of platinum. The mean size, shape, elemental composition of the titanium dioxide nanotubes and platinum deposited on the template were evaluated by different techniques such as field emission scanning electron microscope (FE-SEM), transmission electron microscopy (TEM), X-ray diffraction pattern (XRD), and energy dispersive X-ray (EDX) technique. From all these analyses, the TiO2NTs prepared and Ptnanoparticles deposited on it were ide

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Apr 04 2016
Journal Name
European Journal Of Oral Sciences
Experimental polyethylene-hydroxyapatite carrier-based endodontic system: an in vitro study on dynamic thermomechanical properties, sealing ability, and measurements of micro-computed tomography voids
...Show More Authors

The dynamic thermomechanical properties, sealing ability, and voids formation of an experimental obturation hydroxyapatite-reinforced polyethylene (HA/PE) composite/carrier system were investigated and compared with those of a commercial system [GuttaCore (GC)]. The HA/PE system was specifically designed using a melt-extrusion process. The viscoelastic properties of HA/PE were determined using a dynamic thermomechanical analyser. Human single-rooted teeth were endodontically instrumented and obturated using HA/PE or GC systems, and then sealing ability was assessed using a fluid filtration system. In addition, micro-computed tomography (μCT) was used to quantify apparent voids within the root-canal space. The data were statistically analys

... Show More
View Publication
Crossref (7)
Clarivate Crossref
Publication Date
Sat Jul 01 2017
Journal Name
Energy Procedia
Study characteristics of (epoxy–bentonite doped) composite materials
...Show More Authors

View Publication
Scopus (10)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Aug 11 2020
Journal Name
Bdj Open
An in vitro assessment of the physical properties of manually- mixed and encapsulated glass-ionomer cements
...Show More Authors
Abstract<sec> <title>Objectives

The last decade has seen a variety of modifications of glass-ionomer cements (GICs), such as inclusion of bioactive glass particles and dispensing systems. Hence, the aim was to systematically evaluate effect of mixing modes and presence of reactive glass additives on the physical properties of several GICs.

Materials and methods

The physical properties of eight commercial restorative GICs; Fuji IX GP Extra (C&H), KetacTM Fill Plus Applicap (C&H), Fuji II LC (C&H), Glass Carbomer Ce

... Show More
View Publication Preview PDF
Scopus (28)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Different Pouring Interval of Conventional Impression on the Marginal Accuracy of Full Contour Zirconia Crowns in Comparison with Digital Impression (An in vitro study)
...Show More Authors

Background: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown re

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Different Pouring Interval of Conventional Impression on the Marginal Accuracy of Full Contour Zirconia Crowns in Comparison with Digital Impression (An in vitro study)
...Show More Authors

Background: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown re

... Show More
View Publication
Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Results In Engineering
Push-out test of eco-friendly steel-concrete–steel composite sections enhanced by polypropylene fibers: An experimental study and statistical analysis
...Show More Authors

Steel-concrete-steel (SCS) structural element solutions are rising due to their advantages over conventional reinforced concrete in terms of cost and strength. The impact of SCS sections with various core materials on the structural performance of composites has not yet been fully explored experimentally, and in this work, both slag and polypropylene fibers were incorporated in producing eco-friendly steel-concrete-steel composite sections. This study examined the ductility, ultimate strength, failure modes, and energy absorption capacities of steel-concrete-steel filled with eco-friendly concrete, enhanced by polypropylene fiber (PPF) to understand its impact on modern structural projects. Eco-friendly concrete was produced by the partial

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Apr 04 2022
Journal Name
Journal Of Research In Medical And Dental Science
Efficacy of Varnishes with: Bioactive Glass, Recaldent Technology and Silver Diamine Fluoride in Comparison with Sodium Fluoride on Tooth Surface Micro-hardness (an In Vitro Study)
...Show More Authors

Efficacy of Varnishes with: Bioactive Glass, Recaldent Technology and Silver Diamine Fluoride in Comparison with Sodium Fluoride on Tooth Surface Micro-hardness (an In Vitro Study)

View Publication Preview PDF
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Investigating the impact of non-nutritive sweeteners on the antifungal potential of alcoholic and aqueous Eucalyptus extracts against salivary candida albicans (An in-vitro study)
...Show More Authors

Background: Eucalyptus extracts and derivatives are natural substances with potent antimicrobial properties. This study investigated the in- vitro effects of non-nutritive sweeteners on the antifungal activity of alcoholic and aqueous Eucalyptus extracts against Candida albicans, a common oral pathogen. Materials and Method: Ten isolates of Candida albicans were isolated from dental students’ salivary samples. The alcoholic and aqueous extracts were prepared from fresh Eucalyptus leaves using maceration. The sensitivity of Candida albicans isolates to various concentrations of Eucalyptus extracts ranging from 50 to 250 (mg/mL) was evaluated via agar well diffusion method, while the agar streaking method  was used to assess the minimum

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative Study of The Amount of Apically Extrusion Of Debris During Root Canal Preparation Using Wave Oneâ„¢, Trushape 3Dâ„¢, Hyflexâ„¢ CM and One Shapeâ„¢ Instrumentation Systems (An In Vitro Study)
...Show More Authors

Background: Many types of instruments and techniques are used in the instrumentation of the root canal system. These instruments and techniques may extrude debris beyond the apical foramen and may cause post-instrumentation complications. The aim of this study was to evaluate the amount of apically extruded debris resulted by using 4 types of nickel-titanium instruments (WaveOne, TRUShape 3D conforming files, Hyflex CM, and One Shape files) during endodontic instrumentation. Materials and methods: Forty freshly extracted human mandibular second premolar with straight canals and a single apex were collected for this study. All teeth were cut to similar lengths. Pre-weighted glass vials were used as collecting containers. Samples were randoml

... Show More
View Publication Preview PDF
Crossref (3)
Crossref