Background: Consideration of mandibular third molar is important from orthodontic perspective due to several factors such as, lower anterior arch crowding, relapse in lower anterior region, interference with uprighting of mandibular first and second molars during anchorage preparation and molar distalization. The aims of this study were to assess of gender differences in the mandibular third molar position and compare and evaluate whether there is any differences in the results provided by CT scan and lateral reconstructed radiograph. Materials and Methods: The sample of present study consisted of 39 patients (18 males and 21 females) with age range 11-15 years. CT images for patients who were attending at Al Suwayra General Hospital/the Computerized Tomography department. Computed tomographic images were obtained for The distance from Xi point to distal surface of permanent mandibular second molar was measured in both three dimensional volumetric images and two dimensional CT derived lateral image. The statistical analyses included: means, standard deviations. Paired t-test was used to compare between the two methods and independent t-test was used in verifying the genders difference. Results: The results showed that there was high significant method difference between 3D CT and 2D image and gender differences was observed in values of linear measurements of present study, as males showed higher mean values than females. Conclusion: There is high accuracy of measurement on CT images, so CT scan is advisable during the diagnosis and treatment plan of orthodontic cases.
Metronidazole-MIPs were prepared by using (MDZ) as the template as well as allylchloride (AYC) or allylbromide (AYB) as monomer, used (TMPTA) tri-methylol propane tri-acrylate or ethylene glycol di-methyl acrylate (EGDMA) as cross-linker and initiator used (BP) benzyl peroxide. By using different plasticizers (di butyl Phthalate (DBPH), Nitrobenzene (NB), oleic acid (OA) and paraffin) for MDZ-MIP1 and (Di-butyl sebecate (DBS), Di-methyl acrylate (DMA), Tributylphosphate(TBP) and Tris(ethylhexyl phosphate (TEHP) ) for MDZ-MIP2. Membranes of MIPs were prepared in PVC matrix. The characterizations of each electrode were determined The Slope range from (55.083 - 43.711) mV/decade, Limit of Detection (8 X 10 -4- 2 X 10-6) and Linearity
... Show MoreNanomaterials, including nanoparticles such as iron oxide nanoparticles, have received great attention from researchers due to their unique properties and applications. There are several diverse methods, including chemical, physical, and green biological methods, to prepare iron oxide nanoparticles. The green method was chosen because it is safer, purer, and less toxic compared to other methods. Therefore, the green method is a promising and environmentally friendly method in the near future. The aqueous extract of Iraqi orange leaves was used to prepare nano iron oxide, it was examined structurally and spectrally by several techniques (X-ray diffraction- XRD, Fourier transform infrared - FT-IR, field emission scanning electron micr
... Show MoreBackground: Over the last few years, nanocrystal technology has expanded to improve the bioavailability of poorly water-soluble drugs, which is challenging. Nanocrystals (NCs) exhibit many properties, such as enhancing drug solubility, dissolution, oral absorption, and high drug loading. Ondansetron hydrochloride (ONH) is an antiemetic drug that antagonizes a serotonin 5-HT3 receptor in the peripheral and central nervous system and is widely prescribed for the management of chemotherapy and radiotherapy-induced vomiting and nausea, as well as for postoperative nausea. ONH exhibits approximately 60% bioavailability due to its poor solubility and first-pass metabolism in the liver. Its solubility is pH-dependent, its precipitates abov
... Show MoreBackground: Among individuals who have a stenotic aortic valve, a precise assessment of aortic valve area is essential for clinical judgment. So far, no studies have been conducted to investigate and assess the role of the three dimensional echo-cardiography in the assessment of the valve stenosis. This study aims to compare and assess the precision of the measurement of the stenosis area of the aortic valve by 2D versus 3D echo-cardiography.
The qualified subjects for this study included 33 patients with benign and malignant oral tumors aged 15-75 years and 31 matched age and gender healthy subjects used as control. Proteins measurements included total protein, albumin, globulines in sera and saliva samples, and immunoglobulins (IgG, IgM, IgA) in sera samples of control and patients. Meanwhile, polyacrylamide gel electrophoresis (PAGE) was used to differentiate between protein patterns in both serum and saliva samples among the studied groups. The gel was also stained for glycoprotein to evaluate as well the changes in glycoprotein contents. For total protein, the results revealed a signifigant increase (P?0.01) in both samples (serum and saliva) of patient group. Albumin conce
... Show MoreBackground: Oral lichen planus (OLP) is a chronic inflammatory disease with an autoimmune inflammatory pathogenesis. The purpose of this study was to evaluate the role of angiogenesis in the pathogenesis of OLP, using CD34 stain to highlight the blood vessels for measuring the microvessel density (MVD) as well as to evaluate the relation of this marker with the degree of inflammation Materials and Methods: Immunohistochemical (IHC) staining technique was used to evaluate angiogenesis using CD34 in 46 paraffin blocks 10 of them obtained from normal mucosa and 36 from cases diagnosed as lichen planus , 20 of them diagnosed as Reticular type while 16 as erosive type. Severity of inflammation was divided into mild, moderate and severe accordi
... Show MoreAl-Ruhbah region is located in the southwest of Najaf Governorate. A numerical model was created to simulate groundwater flow and analyze the water quality of the groundwater, by developing a conceptual model within the groundwater modeling system software. Nineteen wells were used, 15 for pumping and four for observation. A three-dimensional model was built based on the cross-sections indicating the geologic layers of the study area, which were composed of five layers. When a distance of 1,000 m between the wells was adopted, 135 wells can be operated simultaneously. These wells were hypothetically operated at 6, 12, and 18 h intervals, with a discharge of 200, 430, and 650 m
Low back pain (LBP) remains one of the most prevalent and disabling musculoskeletal conditions globally, with profound social, economic, and healthcare implications. The rising incidence and chronic nature of LBP highlight the need for more objective, personalized, and effective approaches to assessment and rehabilitation. In this context, bioengineering has emerged as a transformative field, offering novel tools and methodologies that enhance the understanding and management of LBP. This narrative review examines current bioengineering applications in both diagnostic and therapeutic domains. For assessment, technologies such as wearable inertial sensors, three-dimensional motion capture systems, surface electromyography, and biomec
... Show MoreThis article reviews the technical applicability of nanofiltration membrane process for the removal of nickel, lead, and copper ions from industrial wastewater.
Synthetic industrial wastewater samples containing Ni(II), Pb(II), and Cu(II) ions at various concentrations (50, 100, 150 and 200 ppm), under different pressures (1, 2, 3 and 4 bar), temperatures (10, 20, 30 and 40 oC), pH (2, 3, 4, 5 and 5.5), and flow rates (1, 2, 3 and 4 L/hr), were prepared and subjected treated by NF systems in the laboratory. Suitable NF membrane was chosen after testing a number of NF membranes (University of Technology-Baghdad), in terms of production and removal. NF system was capable of removing more than (85%, 78%, and 66% for Ni(II
... Show More