Background: With the increasing demand on esthetic orthodontic appliances, discoloration of clear elastomeric chains and modules remains an issue which concerns both orthodontics and patients. This in vitro study was conducted to evaluate the effect of exposing stretched clear elastomeric chains from six different companies (Ortho Technology, Ormco, Ortho Organizer, American Orthodontics, Opal and G&H companies) to three types of dietary media (tea, coffee and turmeric). Materials and methods: A total of 960 lengths of six modules were cut from short type elastomeric chain; 160 pieces from each brand. The specimens were stretched 50%, placed on plastic boards, and incubated in water at 37°C for 1 day, 7 days, 14 days and 28 days. Once a day, the specimens were immersed for ten minutes in the testing dietary media, washed and then returned back to the water container. Color measurements were made before and after incubation of the specimens. Digital image were taken by an SLR digital camera and the color changes were calculated according to CIE L*a*b* color space system by Adobe Photoshop program. The resulting data were statistically analyzed using ANOVA and LSD tests. Result: Elastomeric chains from AO, Opal and G&H companies were the most brands prone to discoloration. Ortho Organizers and Ortho Technology chains were the least prone to discoloration. Tea, coffee and turmeric solutions discolored elastomeric chains from all companies in a variable degree, however turmeric caused significantly more discoloration, followed by tea and least by coffee. The amount of discoloration caused by tea and coffee increases gradually to peak at 28 days, while most of the discoloration caused by turmeric was in the first day and reached a plateau in a week. Conclusion: To decrease the discoloration of clear elastomeric chains the consumption of colored dietary media especially spices like turmeric are to be discouraged.
The study aims to identify the educational research obstacles as perceived by the faculty members at the universities of south in the west bank. As for study population, it included all (60) faculty-member in the colleges of education (bait lahem, alahliyah, al-khalil, and al-Quds almaftoha). To collect study data, the researcher used a questionnaire that consisted of (43) item; it has categorized into seven-domains: academic working conditions, academic management, resources and information, faculty members, publication, planning, and funding educational research. The findings revealed that Educational research obstacles were high with an average of (4, 39), no significant differences among sample averages and stander deviations on the
... Show MoreBackground: Salivary biomarkers, a non-invasive alternative method to serum and tissue based biomarkers and it is consider as an effective modality for early diagnosis. Salivary microRNA 21, a nucleotide biomarker, was reported to increase in patients with oral squamous cell carcinoma. This study was conducted to measure the fold change of microRNA 21 in stimulated saliva and to study its association with smoking and occurrence of oral squamous cell carcinoma. Materials and methods: A 20 patients with oral squamous cell carcinoma who used to be smokers was included in addition to 40 control subjects (20 smokers and 20 non- smokers health looking subjects). Stimulated saliva was collected under standardized condition. Salivary microRNA 21 wa
... Show MoreA solid Phase Extraction (SPE) followed by HPLC-UV method is described for the simultaneous quantitative determination of nine priority pollutant phenols : Phenol, 2- and 4-Nitrophenol, 2,4-Dimethylphenol, 2-, 2,4-Di-, 2,4,6-Tri-, and Penta- chlorophenol, 4 Chloro-3-methylphenol. The phenols were separated using a C-18 column with UV detector at wave length of 280nm. The Flow of mobile phase was isocratic consisted of 50:50 Acetonitrile: phosphate buffer pH=7.1, column temperature 45 C°, Flow Rate 0.7 ml/min. Calibration curves were linear (R2 = 0.9961-0.9995). The RSDs (1.301-5.805)%, LOD(39.1- 412.4) µg/L, LOQ(118.5-1250.8) µg/L, the Robustness (1.55-4.89), Ruggedness (2.82-4.00), Repeatability (2.1-4.95), Recoveries%
... Show MoreThe High Power Amplifiers (HPAs), which are used in wireless communication, are distinctly characterized by nonlinear properties. The linearity of the HPA can be accomplished by retreating an HPA to put it in a linear region on account of power performance loss. Meanwhile the Orthogonal Frequency Division Multiplex signal is very rough. Therefore, it will be required a large undo to the linear action area that leads to a vital loss in power efficiency. Thereby, back-off is not a positive solution. A Simplicial Canonical Piecewise-Linear (SCPWL) model based digital predistorters are widely employed to compensating the nonlinear distortion that introduced by a HPA component in OFDM technology. In this paper, the genetic al
... Show MoreThis work aimed to prepare and study the characteristic feature of lead nanoparticles (PbNPS) and follow its effects on some physiological aspects in rats.PbNPS was prepared by laser ablation of pure lead mass with a pulse of 500 and 100 mJ of energy. The results indicated that the wavelength was approximately 196 and the concentration was reported at 53,8967 mg / L. AFM, as the average diameter has been estimated at 69.93 nm. EFSEM shows the spherical shape of the particle.The experimental animals (rats) were divided into two groups, with seven rats for each one. The first group was a control and the second group was injected with 1 milliliter of PbNPS (53.8673 mg/l) per day for 45 days. Bioaccumulated lead ( in liver, spleen kidney and
... Show MoreIn this study, simple, low cost, precise and speed spectrophotometric methods development for evaluation of sulfacetamide sodium are described. The primary approach contains conversion of sulfacetamide sodium to diazonium salt followed by a reaction with p-cresol as a reagent in the alkaline media. The colored product has an orange colour with absorbance at λmax 450 nm. At the concentration range of (5.0-100 µg.mL-1), the Beer̆ s Low is obeyed with correlation coefficient (R2= 0.9996), limit of detection as 0.2142 µg.mL-1, limit of quantification as 0.707 µg.mL-1 and molar absorptivity as 1488.249 L.mol-1.cm-1. The other approach, cloud point extraction w
... Show MoreArabian killifish,
In this study, the staging of normal embryonic development of
Combining ultrasonic irradiation and the Fenton process as a sono-Fenton process, the chemical oxygen demand (COD) in refinery wastewater was successfully eliminated using response surface methodology (RSM) with central composite design (CCD). The impact of two main influential operational parameters (iron dosage and reaction time) on the COD removal from wastewater generated by an Iraqi petroleum refinery facility was explored. Removal of 85.81% was attained under the optimal conditions of 21 minutes and 0.289 mM of concentration. Additionally, the results revealed that the concentration of has the highest effect on the COD elimination, followed by reaction time. The high R2 value (96.40%) validated the strong fit of the mo
... Show More