Background: Numerous methods have been described for achievement of Intermaxillary fixation in the treatment of fractures of facial skeleton. Conventional methods like Erich arch bars and eyelet wires are currently the most common methods for achieving intermaxillary fixation (IMF), however, they have their own disadvantages. Since 1989, IMF using intraoral self-tapping IMF screws has been introduced for treatment of mandibular fractures. The aim of this study was to evaluate the efficacy, advantages, disadvantages and potential complications associated with using of self-tapping IMF screws in the treatment of mandibular fractures. Material and Methods: Twenty patients with favorable mandibular fractures, attended to Oral and Maxillofacial Surgery unit, AL-yarmuk Teaching Hospital between November 2014 and October 2015, they were treated with IMF screws. The parameters considered were duration of the procedure, perforations in the gloves, patient acceptance, oral hygiene, iatrogenic dental injuries, mouth opening, healing outcome, occlusal discrepancy and needle stick injuries during IMF. Results: The patients included in this study were 20 (17 males and 3 females). The extremes of age in this study ranged from 12 to 37 years. Three patients had 2 fracture lines. Assault was the most common cause of fractures. The most common site of fracture was the body and parasymphysis regions. Two screws (2.5%) from 80 screws became loosened. One patient (5%) ended with malunion and malocclusion. One patient (5%) developed infection at screw site. Three patients (15%) developed screws soft tissue burying. Conclusion: IMF screws considered to be a useful modality of treatment to establish maxillomandibular fixation. It is safe, and time-sparing technique; however, it is not without limitations or potential consequences in which the surgeon must be aware of in order to provide safe and effective treatment.
Abstract
The aim of the present work is to control of metal buried corrosion by alteration the media method. This method depended on the characteristics of each media. The corrosion rates in different media (soil, sand, porcelanite stone and gravel) for specimens of low carbon steel were measured by two methods weight loss method and polarization method, weight loss measured by buried specimens in these medias separately for 90 days. The polarization method includes preparing of specimen and salt solutions have electrical resistivity equivalent electrical resistivity of these media. The corrosion rate of two method results in (soil > sand> porcelainte stone> gravel). The lower corrosion rate happene
... Show MoreA novel demountable shear connector is proposed to link a concrete slab to steel sections in a way that resulting steel-concrete composite floor is demountable, i.e. it can be easily dismantled at the end of its service life. The proposed connectors consist of two parts: the first part is a hollow steel tube with internal threads at its lower end. The second part is a compatible partially threaded bolted stud. After linking the stud to the steel section, the hollow steel tube can be fastened over the threaded stud, which create a complete demountable shear connector. The connector is suitable for use in both composite bridges and buildings, and using cast in-situ slabs, precast solid slabs, or hollow-core precast slabs. A series of push-off
... Show MoreThe purpose of this study is to examine the experimental, numerical, and analytical behavior of a novel class of composite columns. These columns are designed to replace conventional deformed steel bars with small circular steel tubes filled with cementitious grouting material in a longitudinal orientation. Twelve concrete columns in all were assembled and tested under various loading scenarios. These columns were evaluated under concentric compression load, two eccentric compression loads (25 or 50 mm), and flexural load. They included various forms of reinforcement in a longitudinal direction, including steel bars or tubes. A developed three‐dimensional finite element analysi
The zirconia ceramic restoration (ZCR) is used as substitutes for the metal-ceramic restoration. Clinical studies demonstrating of ZCRs showed a high fracture incidence of veneering layer than metal-ceramic restorations. This attributed to the low bond strength of zirconia to veneering ceramic as a result of lacking of glass content in its matrix. Surface treatment was proposed to improve the bonding strength between zirconia and veneering ceramic. Several studies revealed that some treatment such as airborne particle abrasion (APA) is responsible for generating chipping of veneering ceramic. The study aimed to develop a new zirconia coatings to increase bonding strength between zirconia substrate and veneering porcelain. Three groups of 15
... Show MoreBackground: Acute coronary syndrome (ACS) is a common disease, and a major determinant of morbidity and mortality in all races. The pleiotropic effects of the receptor activator of nuclear factor-kappa B ligand (RANKL) such as modulation of cell survival, mineralization and inflammation, make it an interesting candidate mediator in the progression and destabilization of atherosclerotic lesions.Objectives: This study was performed to investigate the role of RANKL in the pathogenesis of ACS.Methods: The levels of RANKL were measured by ELISA method in sera of 60 ACS patients, 31 patients with unstable angina (UA) and 29 patients with myocardial infarction (MI) in comparison with 20 apparently healthy controls.Results: Current data indicate
... Show MoreBackground: Denture cleansing is an important step that can prevent the spread of infection and improve a patient's health, the durability of the dentures, and the overall quality of life; therefore, it is necessary to choose a suitable cleanser that, in addition to being effective, does not have an unfavorable effect on the qualities of the denture base resin itself when used for an extended period. Aim: This research aims to assess the effects of ozonated water on the surface roughness and hardness of heat-cured acrylic resin by immersion technique. Materials: Sixty bars shapemade of heat-cured acrylicweremanufactured.Thirty samples for every test, including: (surface hardness and surface roughness). Then, these samples were divided into
... Show MoreObjective:To measure the acceptance level of the Personal Digital Assistance (PDA)’suse among nursing students as a tool of education in the Kingdom of Saudi Arabia. Methodology: Eighty-nine nursing students participated in this cross-sectional descriptive study by completing a questionnaire based on the Technology Acceptance Model (TAM) by Davis. Two dimensions were explored and evaluated; (1) the applicability of the TAM model in assessing this technology; and (2) the overall percentage of students’ agreement on the different TAM variables. Results: This study presented significant positive influence bet