Background: Vascular tumors and malformations, comprising a broad category of lesions often referred to as vascular anomalies. Hemangioma, represents a variety of vascular lesions (both malformations and tumor), while lobular capillary hemangioma is a common vascular lesion of the skin and mucous membranes that occurs mainly in children and young adults. Lymphangiomas are malformations of the lymphatic system. At the level of light microscopy the small lymphatics vessels may be similar to capillaries and sometimes are only tentatively identified by the nature of their contents or by immunohistochemical staining procedure. This study aimed to assess the vascular and lymphatic vessels density in benign vascular lesions using CD34 and D2-40 immunohistochemical markers. Materials and Methods: Twenty two formalin-fixed paraffin-embedded tissue blocks of Hemangioma/vascular malformation, thirty of lobular capillary hemangioma and another twenty of lymphangioma. Results: Lymphatic vessel density expressed by D2-40 immunomarker was found in all cases with mean (24.01±14.74) in lymphangioma ,for lobular capillary hemangioma it was (12.67±6.66) and for hemangioma was (9.77±6.82) where as the mean of microvessel density count measured by CD34 immunomarker was (49.87±31.97) for lobular capillary hemangioma , in hemangioma it was (37.42±23.40) and (25.90±12.23 ) for lymphangioma. Conclusions: All vascular lesions are a mixture of blood and lymphatic vessels with different proportions, hemangioma shows high percentage of blood vessels and lymphangioma shows high percentage of lymphatic vessels.
The Local manufacturing scanning gamma system designed in Tuwaitha site for nondestructive assay method of radioactive waste drums, where it consist of two main parts with their belongings for controlling the of detector and drum movements up-down and rotation respectively. The volume of the used drum is 220 L with 85 cm height. The drum filled with Portland cement. Six cylindrical holes were made within cement drum and distributed in radial arrangement.The152Eu source inserted in these holes individually, to measure the average angular count rate of gamma radiation. The full energy efficiency value for geometry of drum and detector is computed for thirteen photo peaks. The average efficiency represented by the curve of these peaks indic
... Show MoreAkaike’s Information Criterion (AIC) is a popular method for estimation the number of sources impinging on an array of sensors, which is a problem of great interest in several applications. The performance of AIC degrades under low Signal-to-Noise Ratio (SNR). This paper is concerned with the development and application of quadrature mirror filters (QMF) for improving the performance of AIC. A new system is proposed to estimate the number of sources by applying AIC to the outputs of filter bank consisting quadrature mirror filters (QMF). The proposed system can estimate the number of sources under low signal-to-noise ratio (SNR).
A spectrophotometric determination of azithromycin was optimized using the simplex model. The approach has been proven to be accurate and sensitive. The analyte has been reacted with bromothymol blue (BTB) to form a colored ion pair which has been extracted in chloroform in a buffer medium of pH=4 of potassium phthalate. The extracted colored product was assayed at 415 nm and exhibited a linear quantification range over (1 - 20) g/ml. The excipients did not exhibit any interferences with the proposed approach for assaying azithromycin in pharmaceutical formulations.
The following dilution 5×10-1, 10-1, 10?2 , 10-3 gm/L for the indigenous isolate of Bacillus thuringiensis bacteria and the commercially isalate were used for experiments against the different stages of fig moth of E.cautella which exposed by filter paper method. The results showed that mortality of larval stages was increased with the increasing concentration of the biocide, in addition to increase in the mortality of the larval stages reached to the highest percentage in the third days of treatment of the larval stage in comparison with the first and second days of exposure. The results also showed that the sensitivity of larval stages was increased in first and second instars while reduced in the last instars .The high percentage
... Show MoreThe effect of α-particle irradiation on the optical absorption in nuclear track detectors (LR115) has been studied. These detectors have been irradiated with different doses. The optical absorption has been measured using the ultraviolet-visible (UV-1100) spectroscopy, that irradiation results in shifting the peaks of the optical absorption. The values of Urbach energy have been calculated from the position of steady-state optical band gap energy, for a standard sample which was unirradiated with indirect influence, has been found 1.9 eV whereas its value after irradiation 1.98 eV. In case of the direct influence, it is found to be, respectively, before irradiation 1.98 eV and after irradiation 2.05 eV. From these results, we can
... Show MoreTwo EM techniques, terrain conductivity and VLF-Radiohm resistivity (using two
different instruments of Geonics EM 34-3 and EMI6R respectively) have been applied to
evaluate their ability in delineation and measuring the depth of shallow subsurface cavities
near Haditha city.
Thirty one survey traverses were achieved to distinguish the subsurface cavities in the
investigated area. Both EM techniques are found to be successfiul tools in study area.
The paper discusses the structural and optical properties of In2O3 and In2O3-SnO2 gas sensor thin films were deposited on glass and silicon substrates and grown by irradiation of assistant microwave on seeded layer nucleated using spin coating technique. The X-ray diffraction revealed a polycrystalline nature of the cubic structure. Atomic Force Microscopy (AFM) used for morphology analysis that shown the grain size of the prepared thin film is less than 100 nm, surface roughness and root mean square for In2O3 where increased after loading SnO2, this addition is a challenge in gas sensing application. Sensitivity of In2O3 thin film against NO2 toxic gas is 35% at 300oC. Sensing properties were improved after adding Tin Oxide (SnO2) to be mo
... Show MoreObjective: To evaluate the client's satisfaction about the services provided in primary health care centers in the
city of Baghdad and its impact on the improvement of services.
Methodology: A simple random sample consisting of (200) clients to primary health care centers in the city of
Baghdad, (15-20) clients for each center using a questionnaire to evaluate the client's satisfaction for the service
and the use of the direct method of interview, which lasts for (6-10) minutes.
Results: Results of the study show that the number of men visits to primary health care centers, fewer women
This indicates that the most important responsibilities of family members and private health care is the
responsibility of women than